These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 30475076)

  • 1. Transdermal sampling of vitamin D
    Mall I; Musteata FM
    Bioanalysis; 2019 Jan; 11(2):61-72. PubMed ID: 30475076
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantification of physiological levels of vitamin D₃ and 25-hydroxyvitamin D₃ in porcine fat and liver in subgram sample sizes.
    Burild A; Frandsen HL; Poulsen M; Jakobsen J
    J Sep Sci; 2014 Oct; 37(19):2659-63. PubMed ID: 25045048
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development and optimization of an LC-MS/MS-based method for simultaneous quantification of vitamin D2 , vitamin D3 , 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3.
    Adamec J; Jannasch A; Huang J; Hohman E; Fleet JC; Peacock M; Ferruzzi MG; Martin B; Weaver CM
    J Sep Sci; 2011 Jan; 34(1):11-20. PubMed ID: 21171171
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quantitation of vitamin D2, vitamin D3, 25-hydroxyvitamin D2, and 25-hydroxyvitamin D3 in human milk.
    Hollis BW; Frank NE
    Methods Enzymol; 1986; 123():167-76. PubMed ID: 3010037
    [No Abstract]   [Full Text] [Related]  

  • 5. Estimation of vitamin D3 and 25-hydroxyvitamin D3 in muscle and adipose tissue of rats and man.
    Lawson DE; Douglas J; Lean M; Sedrani S
    Clin Chim Acta; 1986 Jun; 157(2):175-81. PubMed ID: 3013467
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simultaneous quantification of 25-hydroxyvitamin D
    Gao C; Bergagnini-Kolev MC; Liao MZ; Wang Z; Wong T; Calamia JC; Lin YS; Mao Q; Thummel KE
    J Chromatogr B Analyt Technol Biomed Life Sci; 2017 Aug; 1060():158-165. PubMed ID: 28622619
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of vitamin D
    Castillo-Peinado LLS; Calderón-Santiago M; Sánchez-Cano RL; Quesada-Gómez JM; Bouillon R; Priego-Capote F
    Analyst; 2023 Jan; 148(3):654-664. PubMed ID: 36625245
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development and validation of an LC-MS/MS based method for quantification of 25 hydroxyvitamin D2 and 25 hydroxyvitamin D3 in human serum and plasma.
    Zhang SW; Jian W; Sullivan S; Sankaran B; Edom RW; Weng N; Sharkey D
    J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Jun; 961():62-70. PubMed ID: 24861873
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Two-dimensional liquid chromatography coupled to tandem mass spectrometry for vitamin D metabolite profiling including the C3-epimer-25-monohydroxyvitamin D3.
    Mena-Bravo A; Priego-Capote F; Luque de Castro MD
    J Chromatogr A; 2016 Jun; 1451():50-57. PubMed ID: 27180887
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Investigating transdermal delivery of vitamin D3.
    Alsaqr A; Rasoully M; Musteata FM
    AAPS PharmSciTech; 2015 Aug; 16(4):963-72. PubMed ID: 25609377
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A rapid method for the separation of vitamin D and its metabolites by ultra-high performance supercritical fluid chromatography-mass spectrometry.
    Jumaah F; Larsson S; Essén S; Cunico LP; Holm C; Turner C; Sandahl M
    J Chromatogr A; 2016 Apr; 1440():191-200. PubMed ID: 26931428
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rapid HPLC method for measurement of vitamin D3 and 25(OH)D3 in blood plasma.
    Olkowski AA; Aranda-Osorio G; McKinnon J
    Int J Vitam Nutr Res; 2003 Feb; 73(1):15-8. PubMed ID: 12690906
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Analysis of vitamin D and its metabolites using thermospray liquid chromatography/mass spectrometry.
    Watson D; Setchell KD; Ross R
    Biomed Chromatogr; 1991 Jul; 5(4):153-60. PubMed ID: 1655127
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rapid determination of vitamin D₃ in milk-based infant formulas by liquid chromatography-tandem mass spectrometry.
    Kwak BM; Jeong IS; Lee MS; Ahn JH; Park JS
    Food Chem; 2014 Dec; 165():569-74. PubMed ID: 25038713
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Existence of vitamin D3 and 25-hydroxyvitamin D3 in rat lymph.
    Okano T; Masuda S; Ishimine M; Murai J; Yamamoto Y; Kobayashi T
    Chem Pharm Bull (Tokyo); 1983 Sep; 31(9):3233-41. PubMed ID: 6321046
    [No Abstract]   [Full Text] [Related]  

  • 16. Mechanism of error caused by isotope-labeled internal standard: accurate method for simultaneous measurement of vitamin D and pre-vitamin D by liquid chromatography/tandem mass spectrometry.
    Huang M; Cadwallader AB; Heltsley R
    Rapid Commun Mass Spectrom; 2014 Oct; 28(19):2101-10. PubMed ID: 25156600
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Tissue distribution of 7-dehydrocholesterol, vitamin D3 and 25-hydroxyvitamin D3 in several species of fishes.
    Takeuchi A; Okano T; Sayamoto M; Sawamura S; Kobayashi T; Motosugi M; Yamakawa T
    J Nutr Sci Vitaminol (Tokyo); 1986 Feb; 32(1):13-22. PubMed ID: 3012050
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Rapid and Simple Liquid-Chromatography-Tandem Mass Spectrometry Method for Measuring 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 in Human Serum: Comparison with Two Automated Immunoassays.
    Lee S; Kim JH; Kim SA; Sun YS; Lee A; Park SJ; Kim YT; Lee KR; Kim YJ
    Ann Clin Lab Sci; 2016 Dec; 46(6):645-653. PubMed ID: 27993879
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analysis and quantification of vitamin D metabolites in serum by ultra-performance liquid chromatography coupled to tandem mass spectrometry and high-resolution mass spectrometry--a method comparison and validation.
    Bruce SJ; Rochat B; Béguin A; Pesse B; Guessous I; Boulat O; Henry H
    Rapid Commun Mass Spectrom; 2013 Jan; 27(1):200-6. PubMed ID: 23239334
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Differential extraction of endogenous and exogenous 25-OH-vitamin D from serum makes the accurate quantification in liquid chromatography-tandem mass spectrometry assays challenging.
    Lankes U; Elder PA; Lewis JG; George P
    Ann Clin Biochem; 2015 Jan; 52(Pt 1):151-60. PubMed ID: 24714680
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.