BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 30479625)

  • 1. Inversely designed, 3D-printed personalized template-guided interstitial brachytherapy for vaginal tumors.
    Sekii S; Tsujino K; Kosaka K; Yamaguchi S; Kubota H; Matsumoto Y; Ota Y; Sasaki R; Soejima T
    J Contemp Brachytherapy; 2018 Oct; 10(5):470-477. PubMed ID: 30479625
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Patient-specific cylinder templates for hybrid interstitial vaginal brachytherapy: Feasibility of automated 3-D design, 3D printing, and dosimetric outlook.
    Kudla M; Bachand F; Moore J; Batchelar D
    Brachytherapy; 2023; 22(4):468-476. PubMed ID: 37169607
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Re-irradiation with interstitial brachytherapy in uterine cancer patients with vaginal recurrence after post-operative pelvic irradiation.
    Murofushi KN; Tanaka R; Ohkawa A; Numajiri H; Minakami S; Okumura T; Sakurai H
    J Contemp Brachytherapy; 2022 Feb; 14(1):60-65. PubMed ID: 35233236
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development and assessment of 3D-printed individual applicators in gynecological MRI-guided brachytherapy.
    Logar HBZ; Hudej R; Šegedin B
    J Contemp Brachytherapy; 2019 Apr; 11(2):128-136. PubMed ID: 31139221
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetric comparison of interstitial brachytherapy with multi-channel vaginal cylinder plans in patients with vaginal tumors.
    Mendez LC; Paudel M; Wronski M; Ravi A; Barbera L; Leung E
    Radiat Oncol; 2017 May; 12(1):84. PubMed ID: 28521759
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical outcomes using a 3D printed tandem-needle-template and the EMBRACE-II planning aims for image guided adaptive brachytherapy in locally advanced cervical cancer.
    Cobussen A; Petric P; Wulff CN; Buus S; Spejlborg H; Nielsen SK; Traberg A; Meisner B; Hokland S; Lindegaard JC
    Acta Oncol; 2023 Nov; 62(11):1470-1478. PubMed ID: 37594195
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interstitial brachytherapy using virtual planning and Doppler transrectal ultrasonography guidance for internal iliac lymph node metastasis.
    Yoshida K; Ueda M; Yamazaki H; Takenaka T; Yoshida M; Miyake S; Yoshida S; Koizumi M; Ban C; Tanaka E
    J Radiat Res; 2012; 53(1):154-8. PubMed ID: 22240939
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Inversely and adaptively planned interstitial brachytherapy: A single implant approach.
    Hanania AN; Myers P; Yoder AK; Bulut A; Henry Yu Z; Eraj S; Bowers J; Bonnen MD; Echeverria A; Hall TR; Anderson ML; Ludwig M
    Gynecol Oncol; 2019 Feb; 152(2):353-360. PubMed ID: 30449720
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Three-dimensional-guided perineal-based interstitial brachytherapy in cervical cancer: A systematic review of technique, local control and toxicities.
    Mendez LC; Weiss Y; D'Souza D; Ravi A; Barbera L; Leung E
    Radiother Oncol; 2017 May; 123(2):312-318. PubMed ID: 28351521
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design approach and benefits of the 3D-printed vaginal individualized applicator (VIA).
    Ewongwo A; Niedermayr T; Kidd EA
    Brachytherapy; 2024; 23(3):282-289. PubMed ID: 38402047
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Image-based multichannel vaginal cylinder brachytherapy for the definitive treatment of gynecologic malignancies in the vagina.
    Gebhardt BJ; Vargo JA; Kim H; Houser CJ; Glaser SM; Sukumvanich P; Olawaiye AB; Kelley JL; Edwards RP; Comerci JT; Courtney-Brooks M; Beriwal S
    Gynecol Oncol; 2018 Aug; 150(2):293-299. PubMed ID: 29929925
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Efficacy and safety of a 3D-printed applicator for vaginal brachytherapy in patients with central pelvic-recurrent cervical cancer after primary hysterectomy.
    Qin X; Zhang F; Hou X; Yu L; Yu L; Yan J; Qiu J
    Brachytherapy; 2022; 21(2):193-201. PubMed ID: 34980568
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical applications of custom-made vaginal cylinders constructed using three-dimensional printing technology.
    Sethi R; Cunha A; Mellis K; Siauw T; Diederich C; Pouliot J; Hsu IC
    J Contemp Brachytherapy; 2016 Jun; 8(3):208-14. PubMed ID: 27504130
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-Dose-Rate Interstitial Brachytherapy for Deeply Situated Gynecologic Tumors Guided by Combination of Transrectal and Transabdominal Ultrasonography: A Technical Note.
    Shimizu Y; Murakami N; Chiba T; Kaneda T; Okamoto H; Nakamura S; Takahashi A; Kashihara T; Takahashi K; Inaba K; Okuma K; Nakayama Y; Itami J; Igaki H
    Front Oncol; 2021; 11():808721. PubMed ID: 35155202
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Toward a 3D transrectal ultrasound system for verification of needle placement during high-dose-rate interstitial gynecologic brachytherapy.
    Rodgers JR; Surry K; Leung E; D'Souza D; Fenster A
    Med Phys; 2017 May; 44(5):1899-1911. PubMed ID: 28295403
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A 3D-printed patient-specific applicator guide for use in high-dose-rate interstitial brachytherapy for tongue cancer: a phantom study.
    Choi CH; Kim JI; Park JM
    Phys Med Biol; 2019 Jul; 64(13):135002. PubMed ID: 31170698
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparing multichannel cylinder and 3D-printed applicators for vaginal cuff brachytherapy with preliminary exploration of post-hysterectomy vaginal morphology.
    Yan J; Qin X; Zhang F; Hou X; Yu L; Qiu J
    J Contemp Brachytherapy; 2021 Dec; 13(6):641-648. PubMed ID: 35079250
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improved treatment planning for the Syed-Neblett template using endorectal-coil magnetic resonance and intraoperative (laparotomy/laparoscopy) guidance: a new integrated technique for hysterectomized women with vaginal tumors.
    Corn BW; Lanciano RM; Rosenblum N; Schnall M; King S; Epperson R
    Gynecol Oncol; 1995 Feb; 56(2):255-61. PubMed ID: 7896194
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Vaginal tolerance of CT based image-guided high-dose rate interstitial brachytherapy for gynecological malignancies.
    Murakami N; Kasamatsu T; Sumi M; Yoshimura R; Harada K; Kitaguchi M; Sekii S; Takahashi K; Yoshio K; Inaba K; Morota M; Ito Y; Itami J
    Radiat Oncol; 2014 Jan; 9():31. PubMed ID: 24456669
    [TBL] [Abstract][Full Text] [Related]  

  • 20. 3D image-guided interstitial brachytherapy for primary vaginal cancer: A multi-institutional experience.
    Goodman CD; Mendez LC; Velker V; Weiss Y; Leung E; Louie AV; Warner A; Hajdok G; D'Souza DP
    Gynecol Oncol; 2021 Jan; 160(1):134-139. PubMed ID: 33162177
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.