2. Quantitative bioanalysis of paracetamol in rats using volumetric absorptive microsampling (VAMS). Denniff P; Parry S; Dopson W; Spooner N J Pharm Biomed Anal; 2015 Apr; 108():61-9. PubMed ID: 25710904 [TBL] [Abstract][Full Text] [Related]
3. Comparison of conventional dried blood spots and volumetric absorptive microsampling for tacrolimus and mycophenolic acid determination. Paniagua-González L; Lendoiro E; Otero-Antón E; López-Rivadulla M; de-Castro-Ríos A; Cruz A J Pharm Biomed Anal; 2022 Jan; 208():114443. PubMed ID: 34735994 [TBL] [Abstract][Full Text] [Related]
4. Volumetric absorptive microsampling (VAMS) as an alternative to conventional dried blood spots in the quantification of miltefosine in dried blood samples. Kip AE; Kiers KC; Rosing H; Schellens JHM; Beijnen JH; Dorlo TPC J Pharm Biomed Anal; 2017 Feb; 135():160-166. PubMed ID: 28033553 [TBL] [Abstract][Full Text] [Related]
5. Microsampling Collection Methods for Measurement of C-peptide in Whole Blood. Jones C; Dunseath GJ; Lemon J; Luzio SD J Diabetes Sci Technol; 2018 Sep; 12(5):1024-1028. PubMed ID: 29521111 [TBL] [Abstract][Full Text] [Related]
6. Capillary blood collected on volumetric absorptive microsampling (VAMS) device for monitoring hydroxychloroquine in rheumatoid arthritis patients. Qu Y; Brady K; Apilado R; O'Malley T; Reddy S; Chitkara P; Ibarra C; Alexander RV; Dervieux T J Pharm Biomed Anal; 2017 Jun; 140():334-341. PubMed ID: 28391006 [TBL] [Abstract][Full Text] [Related]
7. Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study. De Kesel PM; Lambert WE; Stove CP Anal Chim Acta; 2015 Jun; 881():65-73. PubMed ID: 26041521 [TBL] [Abstract][Full Text] [Related]
9. Volumetric absorptive microsampling as an alternative sampling strategy for the determination of paracetamol in blood and cerebrospinal fluid. Delahaye L; Dhont E; De Cock P; De Paepe P; Stove CP Anal Bioanal Chem; 2019 Jan; 411(1):181-191. PubMed ID: 30353218 [TBL] [Abstract][Full Text] [Related]
10. Volumetric Absorptive Microsampling in Therapeutic Drug Monitoring of Immunosuppressive Drugs-From Sampling and Analytical Issues to Clinical Application. Kocur A; Pawiński T Int J Mol Sci; 2022 Dec; 24(1):. PubMed ID: 36614123 [TBL] [Abstract][Full Text] [Related]
11. Volumetric absorptive microsampling at home as an alternative tool for the monitoring of HbA1c in diabetes patients. Verougstraete N; Lapauw B; Van Aken S; Delanghe J; Stove C; Stove V Clin Chem Lab Med; 2017 Mar; 55(3):462-469. PubMed ID: 27732552 [TBL] [Abstract][Full Text] [Related]
12. Volumetric absorptive microsampling: a dried sample collection technique for quantitative bioanalysis. Denniff P; Spooner N Anal Chem; 2014 Aug; 86(16):8489-95. PubMed ID: 25058158 [TBL] [Abstract][Full Text] [Related]
13. Pre-analytic evaluation of volumetric absorptive microsampling and integration in a mass spectrometry-based metabolomics workflow. Volani C; Caprioli G; Calderisi G; Sigurdsson BB; Rainer J; Gentilini I; Hicks AA; Pramstaller PP; Weiss G; Smarason SV; Paglia G Anal Bioanal Chem; 2017 Oct; 409(26):6263-6276. PubMed ID: 28815270 [TBL] [Abstract][Full Text] [Related]
14. Volumetric Absorptive Microsampling (VAMS) for assaying immunosuppressants from venous whole blood by LC-MS/MS using a novel atmospheric pressure ionization probe (UniSpray™). Paniagua-González L; Díaz-Louzao C; Lendoiro E; Otero-Antón E; Cadarso-Suárez C; López-Rivadulla M; Cruz A; de-Castro-Ríos A J Pharm Biomed Anal; 2020 Sep; 189():113422. PubMed ID: 32590273 [TBL] [Abstract][Full Text] [Related]
15. Volumetric absorptive microsampling (VAMS) coupled with high-resolution, accurate-mass (HRAM) mass spectrometry as a simplified alternative to dried blood spot (DBS) analysis for therapeutic drug monitoring of cardiovascular drugs. Tanna S; Alalaqi A; Bernieh D; Lawson G Clin Mass Spectrom; 2018 Dec; 10():1-8. PubMed ID: 39193357 [TBL] [Abstract][Full Text] [Related]
16. Determination of oxycodone and its major metabolites in haematic and urinary matrices: Comparison of traditional and miniaturised sampling approaches. Protti M; Catapano MC; Samolsky Dekel BG; Rudge J; Gerra G; Somaini L; Mandrioli R; Mercolini L J Pharm Biomed Anal; 2018 Apr; 152():204-214. PubMed ID: 29414014 [TBL] [Abstract][Full Text] [Related]
17. Development of LC-MS/MS method for quantification of Lurasidone using volumetric absorptive microsampling (VAMS); a comparative study between dried blood and plasma samples. Rajadhyaksha M; Londhe V J Chromatogr B Analyt Technol Biomed Life Sci; 2024 Aug; 1244():124255. PubMed ID: 39059319 [TBL] [Abstract][Full Text] [Related]
19. Opportunities and obstacles for microsampling techniques in bioanalysis: Special focus on DBS and VAMS. Londhe V; Rajadhyaksha M J Pharm Biomed Anal; 2020 Apr; 182():113102. PubMed ID: 32014628 [TBL] [Abstract][Full Text] [Related]
20. Validation and application of volumetric absorptive microsampling (VAMS) dried blood method for phenylalanine measurement in patients with phenylketonuria. Gao L; Smith N; Kaushik D; Milner S; Kong R Clin Biochem; 2023 Jun; 116():65-74. PubMed ID: 37001750 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]