These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 30501304)

  • 1. A cryogenic linear ion trap beamline for providing keV ion bunches.
    Menk S; Bertier P; Enomoto Y; Masunaga T; Majima T; Nakano Y; Azuma T
    Rev Sci Instrum; 2018 Nov; 89(11):113110. PubMed ID: 30501304
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A cryogenic electrostatic trap for long-time storage of keV ion beams.
    Lange M; Froese M; Menk S; Varju J; Bastert R; Blaum K; López-Urrutia JR; Fellenberger F; Grieser M; von Hahn R; Heber O; Kühnel KU; Laux F; Orlov DA; Rappaport ML; Repnow R; Schröter CD; Schwalm D; Shornikov A; Sieber T; Toker Y; Ullrich J; Wolf A; Zajfman D
    Rev Sci Instrum; 2010 May; 81(5):055105. PubMed ID: 20515170
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Model simulations of continuous ion injection into electron-beam ion source trap with slanted electrostatic mirror.
    Pikin A; Kponou A; Alessi JG; Beebe EN; Prelec K; Raparia D
    Rev Sci Instrum; 2008 Feb; 79(2 Pt 2):02B908. PubMed ID: 18315223
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An electron beam ion trap and source for re-acceleration of rare-isotope ion beams at TRIUMF.
    Blessenohl MA; Dobrodey S; Warnecke C; Rosner MK; Graham L; Paul S; Baumann TM; Hockenbery Z; Hubele R; Pfeifer T; Ames F; Dilling J; Crespo López-Urrutia JR
    Rev Sci Instrum; 2018 May; 89(5):052401. PubMed ID: 29864823
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An ultralow-noise superconducting radio-frequency ion trap for frequency metrology with highly charged ions.
    Stark J; Warnecke C; Bogen S; Chen S; Dijck EA; Kühn S; Rosner MK; Graf A; Nauta J; Oelmann JH; Schmöger L; Schwarz M; Liebert D; Spieß LJ; King SA; Leopold T; Micke P; Schmidt PO; Pfeifer T; Crespo López-Urrutia JR
    Rev Sci Instrum; 2021 Aug; 92(8):083203. PubMed ID: 34470420
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cryogenically cooled octupole ion trap for spectroscopy of biomolecular ions.
    Boyarkin OV; Kopysov V
    Rev Sci Instrum; 2014 Mar; 85(3):033105. PubMed ID: 24689562
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A cryogenic radio-frequency ion trap for quantum logic spectroscopy of highly charged ions.
    Leopold T; King SA; Micke P; Bautista-Salvador A; Heip JC; Ospelkaus C; Crespo López-Urrutia JR; Schmidt PO
    Rev Sci Instrum; 2019 Jul; 90(7):073201. PubMed ID: 31370455
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pulsed ion extraction diagnostics in a quadrupole ion trap linear time-of-flight mass spectrometer.
    Dangi BB; Sassin NA; Ervin KM
    Rev Sci Instrum; 2010 Jun; 81(6):063302. PubMed ID: 20590232
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Model for ion injection into a quadrupole ion trap to assess the distribution of initial conditions of confinement.
    Janulyte A; Zerega Y; Carette M; Reynard C; Andre J
    Rapid Commun Mass Spectrom; 2008 Aug; 22(16):2479-92. PubMed ID: 18636422
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design and commissioning of the RIKEN cryogenic electrostatic ring (RICE).
    Nakano Y; Enomoto Y; Masunaga T; Menk S; Bertier P; Azuma T
    Rev Sci Instrum; 2017 Mar; 88(3):033110. PubMed ID: 28372443
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Investigating the use of an octupole ion guide for ion storage and high-pass mass filtering to improve the quantitative performance of electrospray ion trap mass spectrometry.
    Voyksner RD; Lee H
    Rapid Commun Mass Spectrom; 1999; 13(14):1427-37. PubMed ID: 10407334
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A segmented ring, cylindrical ion trap source for time-of-flight mass spectrometry.
    Ji Q; Davenport MR; Enke CG; Holland JF
    J Am Soc Mass Spectrom; 1996 Oct; 7(10):1009-17. PubMed ID: 24202881
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multisectional linear ion trap and novel loading method for optical spectroscopy of electron and nuclear transitions.
    Sysoev AA; Troyan VI; Borisyuk PV; Krasavin AV; Vasiliev OS; Palchikov VG; Avdeev IA; Chernyshev DM; Poteshin SS
    Eur J Mass Spectrom (Chichester); 2015; 21(1):1-12. PubMed ID: 25906029
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Deceleration, precooling, and multi-pass stopping of highly charged ions in Be⁺ Coulomb crystals.
    Schmöger L; Schwarz M; Baumann TM; Versolato OO; Piest B; Pfeifer T; Ullrich J; Schmidt PO; López-Urrutia JR
    Rev Sci Instrum; 2015 Oct; 86(10):103111. PubMed ID: 26520944
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Nondestructive tandem mass spectrometry using a linear quadrupole ion trap coupled to a linear electrostatic ion trap.
    Hilger RT; Santini RE; McLuckey SA
    Anal Chem; 2013 May; 85(10):5226-32. PubMed ID: 23593952
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cluster ion source for external injection and high capacity filling of light elements into the relativistic heavy ion collider electron beam ion source.
    Kondrashev S; Beebe E; Okamura M
    Rev Sci Instrum; 2019 Nov; 90(11):113314. PubMed ID: 31779422
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Origin of mass shifts in the quadrupole ion trap: dissociation of fragile ions observed with a hybrid ion trap/mass filter instrument.
    Murphy JP; Yost RA
    Rapid Commun Mass Spectrom; 2000; 14(4):270-3. PubMed ID: 10669886
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Instrumental development of a quasi-relativistic ultrashort electron beam source for electron diffractions and spectroscopies.
    Shin YM; Figora M
    Rev Sci Instrum; 2017 Oct; 88(10):103302. PubMed ID: 29092527
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A bent electrostatic ion beam trap for simultaneous measurements of fragmentation and ionization of cluster ions.
    Aviv O; Toker Y; Errit M; Bhushan KG; Pedersen HB; Rappaport ML; Heber O; Schwalm D; Zajfman D
    Rev Sci Instrum; 2008 Aug; 79(8):083110. PubMed ID: 19044339
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Injection of externally generated ions into an increasing trapping field of a quadrupole ion trap mass spectrometer.
    Doroshenko VM; Cotter RJ
    J Mass Spectrom; 1997 Jun; 32(6):602-15. PubMed ID: 9218849
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.