These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
142 related articles for article (PubMed ID: 30506174)
21. Performance evaluation of the 5-Ring GE Discovery MI PET/CT system using the national electrical manufacturers association NU 2-2012 Standard. Pan T; Einstein SA; Kappadath SC; Grogg KS; Lois Gomez C; Alessio AM; Hunter WC; El Fakhri G; Kinahan PE; Mawlawi OR Med Phys; 2019 Jul; 46(7):3025-3033. PubMed ID: 31069816 [TBL] [Abstract][Full Text] [Related]
22. Performance evaluation of the next generation solid-state digital photon counting PET/CT system. Zhang J; Maniawski P; Knopp MV EJNMMI Res; 2018 Nov; 8(1):97. PubMed ID: 30402779 [TBL] [Abstract][Full Text] [Related]
23. Studies of a Next-Generation Silicon-Photomultiplier-Based Time-of-Flight PET/CT System. Hsu DFC; Ilan E; Peterson WT; Uribe J; Lubberink M; Levin CS J Nucl Med; 2017 Sep; 58(9):1511-1518. PubMed ID: 28450566 [TBL] [Abstract][Full Text] [Related]
24. Physical performance of the new hybrid PET∕CT Discovery-690. Bettinardi V; Presotto L; Rapisarda E; Picchio M; Gianolli L; Gilardi MC Med Phys; 2011 Oct; 38(10):5394-411. PubMed ID: 21992359 [TBL] [Abstract][Full Text] [Related]
25. NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system. Grant AM; Deller TW; Khalighi MM; Maramraju SH; Delso G; Levin CS Med Phys; 2016 May; 43(5):2334. PubMed ID: 27147345 [TBL] [Abstract][Full Text] [Related]
26. Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes. Mawlawi O; Podoloff DA; Kohlmyer S; Williams JJ; Stearns CW; Culp RF; Macapinlac H; J Nucl Med; 2004 Oct; 45(10):1734-42. PubMed ID: 15471842 [TBL] [Abstract][Full Text] [Related]
27. Performance Characteristics of the Digital Biograph Vision PET/CT System. van Sluis J; de Jong J; Schaar J; Noordzij W; van Snick P; Dierckx R; Borra R; Willemsen A; Boellaard R J Nucl Med; 2019 Jul; 60(7):1031-1036. PubMed ID: 30630944 [TBL] [Abstract][Full Text] [Related]
28. PET optimization for improved assessment and accurate quantification of 90Y-microsphere biodistribution after radioembolization. Martí-Climent JM; Prieto E; Elosúa C; Rodríguez-Fraile M; Domínguez-Prado I; Vigil C; García-Velloso MJ; Arbizu J; Peñuelas I; Richter JA Med Phys; 2014 Sep; 41(9):092503. PubMed ID: 25186412 [TBL] [Abstract][Full Text] [Related]
29. Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 standard. Matsumoto K; Kitamura K; Mizuta T; Tanaka K; Yamamoto S; Sakamoto S; Nakamoto Y; Amano M; Murase K; Senda M J Nucl Med; 2006 Jan; 47(1):83-90. PubMed ID: 16391191 [TBL] [Abstract][Full Text] [Related]
30. Whole-body PET acceptance test in 2D and 3D using NEMA NU 2-2001 protocol. Sharma SD; Prasad R; Shetye B; Rangarajan V; Deshpande D; Shrivastava SK; Dinshaw KA J Med Phys; 2007 Oct; 32(4):150-5. PubMed ID: 21224924 [TBL] [Abstract][Full Text] [Related]
31. NEMA NU2-2012 performance measurements of the United Imaging uPMR790: an integrated PET/MR system. Chen S; Gu Y; Yu H; Chen X; Cao T; Hu L; Shi H Eur J Nucl Med Mol Imaging; 2021 Jun; 48(6):1726-1735. PubMed ID: 33388972 [TBL] [Abstract][Full Text] [Related]
32. An extended bore length solid-state digital-BGO PET/CT system: design, preliminary experience, and performance characteristics. Kennedy JA; Palchan-Hazan T; Maronnier Q; Caselles O; Courbon F; Levy M; Keidar Z Eur J Nucl Med Mol Imaging; 2024 Mar; 51(4):954-964. PubMed ID: 38012446 [TBL] [Abstract][Full Text] [Related]
33. NEMA NU 2-2018 evaluation and image quality optimization of a new generation digital 32-cm axial field-of-view Omni Legend PET-CT using a genetic evolutionary algorithm. Smith RL; Bartley L; O'Callaghan C; Haberska L; Marshall C Biomed Phys Eng Express; 2024 Feb; 10(2):. PubMed ID: 38346328 [TBL] [Abstract][Full Text] [Related]
34. Simulating NEMA characteristics of the modular total-body J-PET scanner-an economic total-body PET from plastic scintillators. Moskal P; Kowalski P; Shopa RY; Raczyński L; Baran J; Chug N; Curceanu C; Czerwiński E; Dadgar M; Dulski K; Gajos A; Hiesmayr BC; Kacprzak K; Kapłon Ł; Kisielewska D; Klimaszewski K; Kopka P; Korcyl G; Krawczyk N; Krzemień W; Kubicz E; Niedźwiecki S; Parzych S; Raj J; Sharma S; Shivani S; Stępień E; Tayefi F; Wiślicki W Phys Med Biol; 2021 Sep; 66(17):. PubMed ID: 34289460 [TBL] [Abstract][Full Text] [Related]
35. Performance Characteristics of a New-Generation Digital Bismuth Germanium Oxide PET/CT System, Omni Legend 32, According to NEMA NU 2-2018 Standards. Yamagishi S; Miwa K; Kamitaki S; Anraku K; Sato S; Yamao T; Kubo H; Miyaji N; Oguchi K J Nucl Med; 2023 Dec; 64(12):1990-1997. PubMed ID: 37857503 [TBL] [Abstract][Full Text] [Related]
36. Technical NEMA NU2-2018 Performance Assessment of Time-of-Flight-Integrated Digital PET-CT System. Singh MK; Agarwal KK; Vishwakarma M; Patel H World J Nucl Med; 2024 Mar; 23(1):10-16. PubMed ID: 38595839 [No Abstract] [Full Text] [Related]
37. Technical Note: Performance evaluation of a small-animal PET/CT system based on NEMA NU 4-2008 standards. Liu Q; Li C; Liu J; Krish K; Fu X; Zhao J; Chen JC Med Phys; 2021 Sep; 48(9):5272-5282. PubMed ID: 34252215 [TBL] [Abstract][Full Text] [Related]
38. Imaging characteristics of a 3-dimensional GSO whole-body PET camera. Surti S; Karp JS J Nucl Med; 2004 Jun; 45(6):1040-9. PubMed ID: 15181139 [TBL] [Abstract][Full Text] [Related]
39. Performance of a whole-body PET scanner using curve-plate NaI(Tl) detectors. Adam LE; Karp JS; Daube-Witherspoon ME; Smith RJ J Nucl Med; 2001 Dec; 42(12):1821-30. PubMed ID: 11752080 [TBL] [Abstract][Full Text] [Related]
40. Performance evaluation of the PennPET explorer with expanded axial coverage. Dai B; Daube-Witherspoon ME; McDonald S; Werner ME; Parma MJ; Geagan MJ; Viswanath V; Karp JS Phys Med Biol; 2023 Apr; 68(9):. PubMed ID: 36958051 [No Abstract] [Full Text] [Related] [Previous] [Next] [New Search]