  • 1. Therapeutic Effect Enhancement by Dual-bias High-voltage Circuit of Transmit Amplifier for Immersion Ultrasound Transducer Applications.
    Choi H; Choe SW
    Sensors (Basel); 2018 Nov; 18(12):. PubMed ID: 30513693
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bias-Voltage Stabilizer for HVHF Amplifiers in VHF Pulse-Echo Measurement Systems.
    Choi H; Park C; Kim J; Jung H
    Sensors (Basel); 2017 Oct; 17(10):. PubMed ID: 29065526
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Inter-Stage Output Voltage Amplitude Improvement Circuit Integrated with Class-B Transmit Voltage Amplifier for Mobile Ultrasound Machines.
    You K; Choi H
    Sensors (Basel); 2020 Nov; 20(21):. PubMed ID: 33147757
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Power MOSFET Linearizer of a High-Voltage Power Amplifier for High-Frequency Pulse-Echo Instrumentation.
    Choi H; Woo PC; Yeom JY; Yoon C
    Sensors (Basel); 2017 Apr; 17(4):. PubMed ID: 28375165
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Post-Voltage-Boost Circuit-Supported Single-Ended Class-B Amplifier for Piezoelectric Transducer Applications.
    Kim J; You K; Choi H
    Sensors (Basel); 2020 Sep; 20(18):. PubMed ID: 32967294
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Power Amplifier Linearizer for High Frequency Medical Ultrasound Applications.
    Choi H; Jung H; Shung KK
    J Med Biol Eng; 2015 Apr; 35(2):226-235. PubMed ID: 26622209
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Harmonic-Reduced Bias Circuit for Ultrasound Transducers.
    Choi H
    Sensors (Basel); 2023 Apr; 23(9):. PubMed ID: 37177641
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Frequency Tuning of Collapse-Mode Capacitive Micromachined Ultrasonic Transducer.
    Pekař M; Dittmer WU; Mihajlović N; van Soest G; de Jong N
    Ultrasonics; 2017 Feb; 74():144-152. PubMed ID: 27780034
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stacked Transistor Bias Circuit of Class-B Amplifier for Portable Ultrasound Systems.
    Choi H
    Sensors (Basel); 2019 Nov; 19(23):. PubMed ID: 31795358
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Crossed SMPS MOSFET-based protection circuit for high frequency ultrasound transceivers and transducers.
    Choi H; Shung KK
    Biomed Eng Online; 2014 Jun; 13():76. PubMed ID: 24924595
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A New Approach to Power Efficiency Improvement of Ultrasonic Transmitters via a Dynamic Bias Technique.
    Kim K; Choi H
    Sensors (Basel); 2021 Apr; 21(8):. PubMed ID: 33921082
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Class-J Power Amplifier Implementation for Ultrasound Device Applications.
    You K; Kim SH; Choi H
    Sensors (Basel); 2020 Apr; 20(8):. PubMed ID: 32316339
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Novel dual-resistor-diode limiter circuit structures for high-voltage reliable ultrasound receiver systems.
    Choi H
    Technol Health Care; 2022; 30(S1):513-520. PubMed ID: 35124625
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An Inverse Class-E Power Amplifier for Ultrasound Transducer.
    Choi H
    Sensors (Basel); 2023 Mar; 23(7):. PubMed ID: 37050526
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Experimental characterization of collapse-mode CMUT operation.
    Oralkan O; Bayram B; Yaralioglu GG; Ergun AS; Kupnik M; Yeh DT; Wygant IO; Khuri-Yakub BT
    IEEE Trans Ultrason Ferroelectr Freq Control; 2006 Aug; 53(8):1513-23. PubMed ID: 16921904
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Class-C Linearized Amplifier for Portable Ultrasound Instruments.
    Choi H
    Sensors (Basel); 2019 Feb; 19(4):. PubMed ID: 30795525
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High-efficiency high-voltage class F amplifier for high-frequency wireless ultrasound systems.
    Kim K; Choi H
    PLoS One; 2021; 16(3):e0249034. PubMed ID: 33780492
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging.
    Wygant IO; Jamal NS; Lee HJ; Nikoozadeh A; Oralkan O; Karaman M; Khuri-Yakub BT
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Oct; 56(10):2145-56. PubMed ID: 19942502
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Investigation of transmit and receive performance at the fundamental and third harmonic resonance frequency of a medical ultrasound transducer.
    Frijlink ME; Løvstakken L; Torp H
    Ultrasonics; 2009 Dec; 49(8):601-4. PubMed ID: 19403153
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ultra-Low-Voltage Capacitive Micromachined Ultrasonic Transducers with Increased Output Pressure Due to Piston-Structured Plates.
    Merbeler F; Wismath S; Haubold M; Bretthauer C; Kupnik M
    Micromachines (Basel); 2022 Apr; 13(5):. PubMed ID: 35630143
    [TBL] [Abstract][Full Text] [Related]  