These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 30514186)

  • 61. Preintervention arterial remodeling affects vessel stretch and plaque extrusion during coronary stent deployment as demonstrated by three-dimensional intravascular ultrasound.
    von Birgelen C; Mintz GS; Eggebrecht H; Herrmann J; Jasper M; Brinkhoff J; Neumann T; Böse D; Baumgart D; Schmermund A; Wieneke H; Haude M; Erbel R
    Am J Cardiol; 2003 Jul; 92(2):130-5. PubMed ID: 12860212
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Virtual bench testing of new generation coronary stents.
    Mortier P; De Beule M; Segers P; Verdonck P; Verhegghe B
    EuroIntervention; 2011 Jul; 7(3):369-76. PubMed ID: 21729840
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Inelasticity of human carotid atherosclerotic plaque.
    Maher E; Creane A; Sultan S; Hynes N; Lally C; Kelly DJ
    Ann Biomed Eng; 2011 Sep; 39(9):2445-55. PubMed ID: 21618044
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Structural and Hemodynamic Analyses of Different Stent Structures in Curved and Stenotic Coronary Artery.
    Wei L; Leo HL; Chen Q; Li Z
    Front Bioeng Biotechnol; 2019; 7():366. PubMed ID: 31867313
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Impact of preinterventional plaque composition and eccentricity on late-acquired incomplete stent apposition after sirolimus-eluting stent implantation: an intravascular ultrasound radiofrequency analysis.
    Sato T; Kameyama T; Noto T; Nozawa T; Inoue H
    Coron Artery Dis; 2012 Nov; 23(7):432-7. PubMed ID: 22936019
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Stent expansion in curved vessel and their interactions: a finite element analysis.
    Wu W; Wang WQ; Yang DZ; Qi M
    J Biomech; 2007; 40(11):2580-5. PubMed ID: 17198706
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Finite element simulation and testing of cobalt-chromium stent: a parametric study on radial strength, recoil, foreshortening, and dogboning.
    Kumar A; Bhatnagar N
    Comput Methods Biomech Biomed Engin; 2021 Feb; 24(3):245-259. PubMed ID: 33021106
    [TBL] [Abstract][Full Text] [Related]  

  • 68. A patient-specific numerical modeling of the spontaneous coronary artery dissection in relation to atherosclerosis.
    Karimi A; Razaghi R; Koyama M
    Comput Methods Programs Biomed; 2019 Dec; 182():105060. PubMed ID: 31514089
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Design optimization of stent and its dilatation balloon using kriging surrogate model.
    Li H; Liu T; Wang M; Zhao D; Qiao A; Wang X; Gu J; Li Z; Zhu B
    Biomed Eng Online; 2017 Jan; 16(1):13. PubMed ID: 28086895
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method.
    Wang WQ; Liang DK; Yang DZ; Qi M
    J Biomech; 2006; 39(1):21-32. PubMed ID: 16271584
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Coronary morphologic findings after stent implantation.
    Grewe PH; Thomas D; Machraoui A; Barmeyer J; Müller KM
    Am J Cardiol; 2000 Mar; 85(5):554-8. PubMed ID: 11078266
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Design optimization of coronary stent based on finite element models.
    Li H; Qiu T; Zhu B; Wu J; Wang X
    ScientificWorldJournal; 2013; 2013():630243. PubMed ID: 24222743
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Comparison of the vulnerability risk for positive versus negative atheroma plaque morphology.
    Cilla M; Peña E; Martínez MA; Kelly DJ
    J Biomech; 2013 Apr; 46(7):1248-54. PubMed ID: 23523380
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Computational analysis of mechanical stress-strain interaction of a bioresorbable scaffold with blood vessel.
    Schiavone A; Abunassar C; Hossainy S; Zhao LG
    J Biomech; 2016 Sep; 49(13):2677-2683. PubMed ID: 27318369
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Investigation of fibrous cap stresses on vulnerable plaques leading to heart attacks.
    Hsiao HM; Wu YY; Tsai BC; Chen YC; Cheng YH
    Technol Health Care; 2015; 24 Suppl 1():S155-61. PubMed ID: 26684564
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Experimental evaluation of a short transitional edge protection balloon for intracoronary stent deployment.
    Carter AJ; Lee DP; Suzuki T; Bailey L; Lansky A; Jones R; Virmani R
    Catheter Cardiovasc Interv; 2000 Sep; 51(1):112-9. PubMed ID: 10973033
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Stratification of risk in thin cap fibroatheromas using peak plaque stress estimates from idealized finite element models.
    Dolla WJ; House JA; Marso SP
    Med Eng Phys; 2012 Nov; 34(9):1330-8. PubMed ID: 22342558
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Rotational atherectomy: if you do not do it before, you can do it after stenting.
    Hernandez J; Galeote G; Moreno R
    J Invasive Cardiol; 2014 Sep; 26(9):E122-3. PubMed ID: 25198495
    [TBL] [Abstract][Full Text] [Related]  

  • 79. A numerical model to study the interaction of vascular stents with human atherosclerotic lesions.
    Kiousis DE; Gasser TC; Holzapfel GA
    Ann Biomed Eng; 2007 Nov; 35(11):1857-69. PubMed ID: 17647105
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Finite element analysis of balloon-expandable coronary stent deployment: influence of angioplasty balloon configuration.
    Martin D; Boyle F
    Int J Numer Method Biomed Eng; 2013 Nov; 29(11):1161-75. PubMed ID: 23696255
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.