These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 30515625)

  • 1. Lesion index: a novel guide in the path of successful pulmonary vein isolation.
    Dello Russo A; Fassini GM; Casella M; Romanelli E; Pala S; Riva S; Catto V; Moltrasio M; Tundo F; Zucchetti M; Majocchi B; Dessanai MA; Pizzamiglio F; Vettor G; Ribatti V; Gasperetti A; Cellucci S; Negro G; Sicuso R; Carbucicchio C; Tondo C
    J Interv Card Electrophysiol; 2019 Jun; 55(1):27-34. PubMed ID: 30515625
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical outcome of lesion size index-guided high-power radiofrequency catheter ablation for pulmonary vein isolation in patients with atrial fibrillation: 2-year follow-up.
    Cai C; Wang J; Niu HX; Chu JM; Hua W; Zhang S; Yao Y
    J Cardiovasc Electrophysiol; 2023 Mar; 34(3):546-555. PubMed ID: 36640429
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impact of the pulmonary vein orifice area assessed using intracardiac echocardiography on the outcome of radiofrequency catheter ablation for atrial fibrillation.
    Nakashima T; Kawasaki M; Toyoshi H; Takasugi N; Kubota T; Kanamori H; Ushikoshi H; Aoyama T; Nishigaki K; Minatoguchi S
    J Interv Card Electrophysiol; 2018 Mar; 51(2):133-142. PubMed ID: 29445983
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mechanisms of pulmonary vein reconnection after radiofrequency ablation of atrial fibrillation: the deterministic role of contact force and interlesion distance.
    Park CI; Lehrmann H; Keyl C; Weber R; Schiebeling J; Allgeier J; Schurr P; Shah A; Neumann FJ; Arentz T; Jadidi AS
    J Cardiovasc Electrophysiol; 2014 Jul; 25(7):701-8. PubMed ID: 24575734
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimal lesion size index to prevent conduction gap during pulmonary vein isolation.
    Kanamori N; Kato T; Sakagami S; Saeki T; Kato C; Kawai K; Chikata A; Takashima SI; Murai H; Usui S; Furusho H; Kaneko S; Takamura M
    J Cardiovasc Electrophysiol; 2018 Dec; 29(12):1616-1623. PubMed ID: 30176083
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Single 3-min freeze per vein ablation strategy with the second-generation cryoballoon for atrial fibrillation in a large cohort of patients: long term outcome after a single procedure.
    Coutiño HE; Abugattas JP; Sieira J; Salghetti F; Ströker E; Paparella G; Haine E; Varnavas V; Umbrain V; Terasawa M; De Greef Y; Brugada P; Iacopino S; de Asmundis C; Chierchia GB
    J Interv Card Electrophysiol; 2018 Oct; 53(1):81-89. PubMed ID: 29948587
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Catheter-tissue contact force values do not impact mid-term clinical outcome following pulmonary vein isolation in patients with paroxysmal atrial fibrillation.
    Stabile G; Solimene F; Calò L; Anselmino M; Castro A; Pratola C; Golia P; Bottoni N; Grandinetti G; De Simone A; Schillaci V; Bertaglia E; De Ponti R
    J Interv Card Electrophysiol; 2015 Jan; 42(1):21-6. PubMed ID: 25378035
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Low contact force and force-time integral predict early recovery and dormant conduction revealed by adenosine after pulmonary vein isolation.
    le Polain de Waroux JB; Weerasooriya R; Anvardeen K; Barbraud C; Marchandise S; De Meester C; Goesaert C; Reis I; Scavee C
    Europace; 2015 Jun; 17(6):877-83. PubMed ID: 25618742
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation.
    Ghosh J; Martin A; Keech AC; Chan KH; Gomes S; Singarayar S; McGuire MA
    Heart Rhythm; 2013 Sep; 10(9):1311-7. PubMed ID: 23792110
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simultaneous pace-ablate during CARTO-guided pulmonary vein isolation with a contact-force sensing radiofrequency ablation catheter.
    Barbhaiya CR; Aizer A; Knotts R; Bernstein S; Park D; Holmes D; Chinitz LA
    J Interv Card Electrophysiol; 2019 Mar; 54(2):119-124. PubMed ID: 30264289
    [TBL] [Abstract][Full Text] [Related]  

  • 11. General anesthesia improves contact force and reduces gap formation in pulmonary vein isolation: a comparison with conscious sedation.
    Chikata A; Kato T; Yaegashi T; Sakagami S; Kato C; Saeki T; Kawai K; Takashima SI; Murai H; Usui S; Furusho H; Kaneko S; Takamura M
    Heart Vessels; 2017 Aug; 32(8):997-1005. PubMed ID: 28260190
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimal Lesion Size Index for Pulmonary Vein Isolation in High-Power Radiofrequency Catheter Ablation of Atrial Fibrillation.
    Cai C; Wang J; Niu HX; Chu JM; Hua W; Zhang S; Yao Y
    Front Cardiovasc Med; 2022; 9():869254. PubMed ID: 35463774
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Atrial fibrillation ablation using very short duration 50 W ablations and contact force sensing catheters.
    Winkle RA; Moskovitz R; Hardwin Mead R; Engel G; Kong MH; Fleming W; Salcedo J; Patrawala RA; Tranter JH; Shai I
    J Interv Card Electrophysiol; 2018 Jun; 52(1):1-8. PubMed ID: 29460232
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study.
    Neuzil P; Reddy VY; Kautzner J; Petru J; Wichterle D; Shah D; Lambert H; Yulzari A; Wissner E; Kuck KH
    Circ Arrhythm Electrophysiol; 2013 Apr; 6(2):327-33. PubMed ID: 23515263
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Catheter-tissue contact force determines atrial electrogram characteristics before and lesion efficacy after antral pulmonary vein isolation in humans.
    Kumar S; Chan M; Lee J; Wong MC; Yudi M; Morton JB; Spence SJ; Halloran K; Kistler PM; Kalman JM
    J Cardiovasc Electrophysiol; 2014 Feb; 25(2):122-9. PubMed ID: 24102727
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative magnetic resonance imaging analysis of the relationship between contact force and left atrial scar formation after catheter ablation of atrial fibrillation.
    Sohns C; Karim R; Harrison J; Arujuna A; Linton N; Sennett R; Lambert H; Leo G; Williams S; Razavi R; Wright M; Schaeffter T; O'Neill M; Rhode K
    J Cardiovasc Electrophysiol; 2014 Feb; 25(2):138-45. PubMed ID: 24118197
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determinants of Acute and Late Pulmonary Vein Reconnection in Contact Force-Guided Pulmonary Vein Isolation: Identifying the Weakest Link in the Ablation Chain.
    El Haddad M; Taghji P; Phlips T; Wolf M; Demolder A; Choudhury R; Knecht S; Vandekerckhove Y; Tavernier R; Nakagawa H; Duytschaever M
    Circ Arrhythm Electrophysiol; 2017 Apr; 10(4):. PubMed ID: 28381417
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Analysis of late reconnections after pulmonary vein isolation: Impact of interlesion contiguity and ablation index.
    Pedrote A; Acosta J; Frutos-López M; Jáuregui-Garrido B; Alarcón F; Arana-Rueda E
    Pacing Clin Electrophysiol; 2019 Jun; 42(6):678-685. PubMed ID: 30912154
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Vasovagal responses during cryoballoon pulmonary vein isolation in paroxysmal atrial fibrillation predict favorable mid-term outcomes.
    Te ALD; Lo LW; Lin YJ; Chang SL; Hu YF; Chung FP; Tuan TC; Chao TF; Liao JN; Chang YT; Lin CY; Yamada S; Chang TY; Salim S; Hoang MQ; Huang TC; Chen SA
    Int J Cardiol; 2018 May; 258():115-120. PubMed ID: 29467097
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Arrhythmia-free survival and pulmonary vein reconnection patterns after second-generation cryoballoon and contact-force radiofrequency pulmonary vein isolation.
    Buist TJ; Adiyaman A; Smit JJJ; Ramdat Misier AR; Elvan A
    Clin Res Cardiol; 2018 Jun; 107(6):498-506. PubMed ID: 29411114
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.