6. Single 3-min freeze per vein ablation strategy with the second-generation cryoballoon for atrial fibrillation in a large cohort of patients: long term outcome after a single procedure. Coutiño HE; Abugattas JP; Sieira J; Salghetti F; Ströker E; Paparella G; Haine E; Varnavas V; Umbrain V; Terasawa M; De Greef Y; Brugada P; Iacopino S; de Asmundis C; Chierchia GB J Interv Card Electrophysiol; 2018 Oct; 53(1):81-89. PubMed ID: 29948587 [TBL] [Abstract][Full Text] [Related]
7. Catheter-tissue contact force values do not impact mid-term clinical outcome following pulmonary vein isolation in patients with paroxysmal atrial fibrillation. Stabile G; Solimene F; Calò L; Anselmino M; Castro A; Pratola C; Golia P; Bottoni N; Grandinetti G; De Simone A; Schillaci V; Bertaglia E; De Ponti R J Interv Card Electrophysiol; 2015 Jan; 42(1):21-6. PubMed ID: 25378035 [TBL] [Abstract][Full Text] [Related]
8. Low contact force and force-time integral predict early recovery and dormant conduction revealed by adenosine after pulmonary vein isolation. le Polain de Waroux JB; Weerasooriya R; Anvardeen K; Barbraud C; Marchandise S; De Meester C; Goesaert C; Reis I; Scavee C Europace; 2015 Jun; 17(6):877-83. PubMed ID: 25618742 [TBL] [Abstract][Full Text] [Related]
9. Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation. Ghosh J; Martin A; Keech AC; Chan KH; Gomes S; Singarayar S; McGuire MA Heart Rhythm; 2013 Sep; 10(9):1311-7. PubMed ID: 23792110 [TBL] [Abstract][Full Text] [Related]
10. Simultaneous pace-ablate during CARTO-guided pulmonary vein isolation with a contact-force sensing radiofrequency ablation catheter. Barbhaiya CR; Aizer A; Knotts R; Bernstein S; Park D; Holmes D; Chinitz LA J Interv Card Electrophysiol; 2019 Mar; 54(2):119-124. PubMed ID: 30264289 [TBL] [Abstract][Full Text] [Related]
11. General anesthesia improves contact force and reduces gap formation in pulmonary vein isolation: a comparison with conscious sedation. Chikata A; Kato T; Yaegashi T; Sakagami S; Kato C; Saeki T; Kawai K; Takashima SI; Murai H; Usui S; Furusho H; Kaneko S; Takamura M Heart Vessels; 2017 Aug; 32(8):997-1005. PubMed ID: 28260190 [TBL] [Abstract][Full Text] [Related]
12. Optimal Lesion Size Index for Pulmonary Vein Isolation in High-Power Radiofrequency Catheter Ablation of Atrial Fibrillation. Cai C; Wang J; Niu HX; Chu JM; Hua W; Zhang S; Yao Y Front Cardiovasc Med; 2022; 9():869254. PubMed ID: 35463774 [TBL] [Abstract][Full Text] [Related]
13. Atrial fibrillation ablation using very short duration 50 W ablations and contact force sensing catheters. Winkle RA; Moskovitz R; Hardwin Mead R; Engel G; Kong MH; Fleming W; Salcedo J; Patrawala RA; Tranter JH; Shai I J Interv Card Electrophysiol; 2018 Jun; 52(1):1-8. PubMed ID: 29460232 [TBL] [Abstract][Full Text] [Related]
14. Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study. Neuzil P; Reddy VY; Kautzner J; Petru J; Wichterle D; Shah D; Lambert H; Yulzari A; Wissner E; Kuck KH Circ Arrhythm Electrophysiol; 2013 Apr; 6(2):327-33. PubMed ID: 23515263 [TBL] [Abstract][Full Text] [Related]
15. Catheter-tissue contact force determines atrial electrogram characteristics before and lesion efficacy after antral pulmonary vein isolation in humans. Kumar S; Chan M; Lee J; Wong MC; Yudi M; Morton JB; Spence SJ; Halloran K; Kistler PM; Kalman JM J Cardiovasc Electrophysiol; 2014 Feb; 25(2):122-9. PubMed ID: 24102727 [TBL] [Abstract][Full Text] [Related]
16. Quantitative magnetic resonance imaging analysis of the relationship between contact force and left atrial scar formation after catheter ablation of atrial fibrillation. Sohns C; Karim R; Harrison J; Arujuna A; Linton N; Sennett R; Lambert H; Leo G; Williams S; Razavi R; Wright M; Schaeffter T; O'Neill M; Rhode K J Cardiovasc Electrophysiol; 2014 Feb; 25(2):138-45. PubMed ID: 24118197 [TBL] [Abstract][Full Text] [Related]
17. Determinants of Acute and Late Pulmonary Vein Reconnection in Contact Force-Guided Pulmonary Vein Isolation: Identifying the Weakest Link in the Ablation Chain. El Haddad M; Taghji P; Phlips T; Wolf M; Demolder A; Choudhury R; Knecht S; Vandekerckhove Y; Tavernier R; Nakagawa H; Duytschaever M Circ Arrhythm Electrophysiol; 2017 Apr; 10(4):. PubMed ID: 28381417 [TBL] [Abstract][Full Text] [Related]
18. Analysis of late reconnections after pulmonary vein isolation: Impact of interlesion contiguity and ablation index. Pedrote A; Acosta J; Frutos-López M; Jáuregui-Garrido B; Alarcón F; Arana-Rueda E Pacing Clin Electrophysiol; 2019 Jun; 42(6):678-685. PubMed ID: 30912154 [TBL] [Abstract][Full Text] [Related]
19. Vasovagal responses during cryoballoon pulmonary vein isolation in paroxysmal atrial fibrillation predict favorable mid-term outcomes. Te ALD; Lo LW; Lin YJ; Chang SL; Hu YF; Chung FP; Tuan TC; Chao TF; Liao JN; Chang YT; Lin CY; Yamada S; Chang TY; Salim S; Hoang MQ; Huang TC; Chen SA Int J Cardiol; 2018 May; 258():115-120. PubMed ID: 29467097 [TBL] [Abstract][Full Text] [Related]
20. Arrhythmia-free survival and pulmonary vein reconnection patterns after second-generation cryoballoon and contact-force radiofrequency pulmonary vein isolation. Buist TJ; Adiyaman A; Smit JJJ; Ramdat Misier AR; Elvan A Clin Res Cardiol; 2018 Jun; 107(6):498-506. PubMed ID: 29411114 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]