These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 30524028)

  • 1. On the robustness of real-time myoelectric control investigations: a multiday Fitts' law approach.
    Waris A; Mendez I; Englehart K; Jensen W; Kamavuako EN
    J Neural Eng; 2019 Apr; 16(2):026003. PubMed ID: 30524028
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Multiday Evaluation of Real-Time Intramuscular EMG Usability with ANN.
    Waris A; Zia Ur Rehman M; Niazi IK; Jochumsen M; Englehart K; Jensen W; Haavik H; Kamavuako EN
    Sensors (Basel); 2020 Jun; 20(12):. PubMed ID: 32549396
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Support vector regression for improved real-time, simultaneous myoelectric control.
    Ameri A; Kamavuako EN; Scheme EJ; Englehart KB; Parker PA
    IEEE Trans Neural Syst Rehabil Eng; 2014 Nov; 22(6):1198-209. PubMed ID: 24846649
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A real-time comparison between direct control, sequential pattern recognition control and simultaneous pattern recognition control using a Fitts' law style assessment procedure.
    Wurth SM; Hargrove LJ
    J Neuroeng Rehabil; 2014 May; 11():91. PubMed ID: 24886664
    [TBL] [Abstract][Full Text] [Related]  

  • 5. On the usability of intramuscular EMG for prosthetic control: a Fitts' Law approach.
    Kamavuako EN; Scheme EJ; Englehart KB
    J Electromyogr Kinesiol; 2014 Oct; 24(5):770-7. PubMed ID: 25048642
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Motion Normalized Proportional Control for Improved Pattern Recognition-Based Myoelectric Control.
    Scheme E; Lock B; Hargrove L; Hill W; Kuruganti U; Englehart K
    IEEE Trans Neural Syst Rehabil Eng; 2014 Jan; 22(1):149-57. PubMed ID: 23475378
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Confidence-based rejection for improved pattern recognition myoelectric control.
    Scheme EJ; Hudgins BS; Englehart KB
    IEEE Trans Biomed Eng; 2013 Jun; 60(6):1563-70. PubMed ID: 23322756
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Real-time comparison of conventional direct control and pattern recognition myoelectric control in a two-dimensional Fitts' law style test.
    Wurth SM; Hargrove LJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():3630-3. PubMed ID: 24110516
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Affordable Embroidered EMG Electrodes for Myoelectric Control of Prostheses: A Pilot Study.
    Kamavuako EN; Brown M; Bao X; Chihi I; Pitou S; Howard M
    Sensors (Basel); 2021 Aug; 21(15):. PubMed ID: 34372482
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multiday Evaluation of Techniques for EMG-Based Classification of Hand Motions.
    Waris A; Niazi IK; Jamil M; Englehart K; Jensen W; Kamavuako EN
    IEEE J Biomed Health Inform; 2019 Jul; 23(4):1526-1534. PubMed ID: 30106701
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Real-time, simultaneous myoelectric control using a convolutional neural network.
    Ameri A; Akhaee MA; Scheme E; Englehart K
    PLoS One; 2018; 13(9):e0203835. PubMed ID: 30212573
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of Confidence-Based Rejection on Usability and Error in Pattern Recognition-Based Myoelectric Control.
    Robertson JW; Englehart KB; Scheme EJ
    IEEE J Biomed Health Inform; 2019 Sep; 23(5):2002-2008. PubMed ID: 30387754
    [TBL] [Abstract][Full Text] [Related]  

  • 13. FMG Versus EMG: A Comparison of Usability for Real-Time Pattern Recognition Based Control.
    Belyea A; Englehart K; Scheme E
    IEEE Trans Biomed Eng; 2019 Nov; 66(11):3098-3104. PubMed ID: 30794502
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Real-time simultaneous and proportional myoelectric control using intramuscular EMG.
    Smith LH; Kuiken TA; Hargrove LJ
    J Neural Eng; 2014 Dec; 11(6):066013. PubMed ID: 25394366
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Role of Muscle Synergies in Real-Time Classification of Upper Limb Motions using Extreme Learning Machines.
    Antuvan CW; Bisio F; Marini F; Yen SC; Cambria E; Masia L
    J Neuroeng Rehabil; 2016 Aug; 13(1):76. PubMed ID: 27527511
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation of a selective ensemble-based classification scheme for myoelectric control using a three-dimensional Fitts' Law test.
    Scheme EJ; Englehart KB
    IEEE Trans Neural Syst Rehabil Eng; 2013 Jul; 21(4):616-23. PubMed ID: 23193252
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improving the Robustness of Myoelectric Pattern Recognition for Upper Limb Prostheses by Covariate Shift Adaptation.
    Vidovic MM; Hwang HJ; Amsuss S; Hahne JM; Farina D; Muller KR
    IEEE Trans Neural Syst Rehabil Eng; 2016 Sep; 24(9):961-970. PubMed ID: 26513794
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Interface Prostheses With Classifier-Feedback-Based User Training.
    Fang Y; Zhou D; Li K; Liu H
    IEEE Trans Biomed Eng; 2017 Nov; 64(11):2575-2583. PubMed ID: 28026744
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improved prosthetic hand control with concurrent use of myoelectric and inertial measurements.
    Krasoulis A; Kyranou I; Erden MS; Nazarpour K; Vijayakumar S
    J Neuroeng Rehabil; 2017 Jul; 14(1):71. PubMed ID: 28697795
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved Prosthetic Control Based on Myoelectric Pattern Recognition via Wavelet-Based De-Noising.
    Maier J; Naber A; Ortiz-Catalan M
    IEEE Trans Neural Syst Rehabil Eng; 2018 Feb; 26(2):506-514. PubMed ID: 29432116
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.