These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

92 related articles for article (PubMed ID: 30524028)

  • 21. Improved Prosthetic Control Based on Myoelectric Pattern Recognition via Wavelet-Based De-Noising.
    Maier J; Naber A; Ortiz-Catalan M
    IEEE Trans Neural Syst Rehabil Eng; 2018 Feb; 26(2):506-514. PubMed ID: 29432116
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Resolving the effect of wrist position on myoelectric pattern recognition control.
    Adewuyi AA; Hargrove LJ; Kuiken TA
    J Neuroeng Rehabil; 2017 May; 14(1):39. PubMed ID: 28472991
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Nonlinear mappings between discrete and simultaneous motions to decrease training burden of simultaneous pattern recognition myoelectric control.
    Ingraham KA; Smith LH; Simon AM; Hargrove LJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():1675-8. PubMed ID: 26736598
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation of Myoelectric Control Learning Using Multi-Session Game-Based Training.
    Tabor A; Bateman S; Scheme E
    IEEE Trans Neural Syst Rehabil Eng; 2018 Sep; 26(9):1680-1689. PubMed ID: 30010580
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Real-Time Surface EMG Pattern Recognition for Hand Gestures Based on an Artificial Neural Network.
    Zhang Z; Yang K; Qian J; Zhang L
    Sensors (Basel); 2019 Jul; 19(14):. PubMed ID: 31323888
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Improving the Robustness of Real-Time Myoelectric Pattern Recognition against Arm Position Changes in Transradial Amputees.
    Geng Y; Samuel OW; Wei Y; Li G
    Biomed Res Int; 2017; 2017():5090454. PubMed ID: 28523276
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Real-time and offline performance of pattern recognition myoelectric control using a generic electrode grid with targeted muscle reinnervation patients.
    Tkach DC; Young AJ; Smith LH; Rouse EJ; Hargrove LJ
    IEEE Trans Neural Syst Rehabil Eng; 2014 Jul; 22(4):727-34. PubMed ID: 24760931
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Reduced Daily Recalibration of Myoelectric Prosthesis Classifiers Based on Domain Adaptation.
    Liu J; Sheng X; Zhang D; He J; Zhu X
    IEEE J Biomed Health Inform; 2016 Jan; 20(1):166-76. PubMed ID: 25532196
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Evaluation of Computer-Based Target Achievement Tests for Myoelectric Control.
    Gusman J; Mastinu E; Ortiz-Catalan M
    IEEE J Transl Eng Health Med; 2017; 5():2100310. PubMed ID: 29255654
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Anticipatory postural adjustments during a Fitts' task: Comparing young versus older adults and the effects of different foci of attention.
    Aloraini SM; Glazebrook CM; Sibley KM; Singer J; Passmore S
    Hum Mov Sci; 2019 Apr; 64():366-377. PubMed ID: 30856380
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Electrode Density Affects the Robustness of Myoelectric Pattern Recognition System With and Without Electrode Shift.
    He J; Sheng X; Zhu X; Jiang N
    IEEE J Biomed Health Inform; 2019 Jan; 23(1):156-163. PubMed ID: 29994645
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Selective classification for improved robustness of myoelectric control under nonideal conditions.
    Scheme EJ; Englehart KB; Hudgins BS
    IEEE Trans Biomed Eng; 2011 Jun; 58(6):1698-705. PubMed ID: 21317073
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Real-time, simultaneous myoelectric control using force and position-based training paradigms.
    Ameri A; Scheme EJ; Kamavuako EN; Englehart KB; Parker PA
    IEEE Trans Biomed Eng; 2014 Feb; 61(2):279-87. PubMed ID: 24058007
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparing the Effects of Signal Noise on Pattern Recognition and Linear Regression-Based Myoelectric Controllers.
    Teh Y; Woodward RB; Hargrove LJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():2132-2135. PubMed ID: 30440825
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Towards limb position invariant myoelectric pattern recognition using time-dependent spectral features.
    Khushaba RN; Takruri M; Miro JV; Kodagoda S
    Neural Netw; 2014 Jul; 55():42-58. PubMed ID: 24721224
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Children with congenital spastic hemiplegia obey Fitts' Law in a visually guided tapping task.
    Smits-Engelsman BC; Rameckers EA; Duysens J
    Exp Brain Res; 2007 Mar; 177(4):431-9. PubMed ID: 17019607
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Real-time robustness evaluation of regression based myoelectric control against arm position change and donning/doffing.
    Hwang HJ; Hahne JM; Müller KR
    PLoS One; 2017; 12(11):e0186318. PubMed ID: 29095846
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Evaluation of Linear Regression Simultaneous Myoelectric Control Using Intramuscular EMG.
    Smith LH; Kuiken TA; Hargrove LJ
    IEEE Trans Biomed Eng; 2016 Apr; 63(4):737-46. PubMed ID: 26302506
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Multiday EMG-Based Classification of Hand Motions with Deep Learning Techniques.
    Zia Ur Rehman M; Waris A; Gilani SO; Jochumsen M; Niazi IK; Jamil M; Farina D; Kamavuako EN
    Sensors (Basel); 2018 Aug; 18(8):. PubMed ID: 30071617
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Online mapping of EMG signals into kinematics by autoencoding.
    Vujaklija I; Shalchyan V; Kamavuako EN; Jiang N; Marateb HR; Farina D
    J Neuroeng Rehabil; 2018 Mar; 15(1):21. PubMed ID: 29534764
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]