These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 3053018)

  • 1. High-frequency hearing of dental personnel.
    Rahko AA; Karma PH; Rahko KT; Kataja MJ
    Community Dent Oral Epidemiol; 1988 Oct; 16(5):268-70. PubMed ID: 3053018
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [The long-term effects of noise on dentists].
    Reitemeier B; Fritsche F
    Zahn Mund Kieferheilkd Zentralbl; 1990; 78(8):735-8. PubMed ID: 2150465
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Findings of standard and high-frequency audiometry in workers exposed to occupational noise for long durations].
    Türkkahraman S; Gök U; Karlidağ T; Keleş E; Oztürk A
    Kulak Burun Bogaz Ihtis Derg; 2003 Apr; 10(4):137-42. PubMed ID: 12941983
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dentists' hearing and exposure to high speed turbine dental drill noise.
    Lehto T
    Proc Finn Dent Soc; 1990; 86(3-4):115-25. PubMed ID: 2094844
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Efficient hearing screening in noise-exposed listeners using the digit triplet test.
    Jansen S; Luts H; Dejonckere P; van Wieringen A; Wouters J
    Ear Hear; 2013; 34(6):773-8. PubMed ID: 23782715
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Is there noise-induced hearing loss in the low and middle tone frequencies?].
    Chüden H
    Laryngol Rhinol Otol (Stuttg); 1983 Oct; 62(10):481-4. PubMed ID: 6645750
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Occupational safety threats among dental personnel and related risk factors.
    Gurbuz MK; Çatli T; Cingi C; Yaz A; Bal C
    J Craniofac Surg; 2013 Nov; 24(6):e599-602. PubMed ID: 24220478
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High frequency thresholds: variations with age and industrial noise exposure.
    Morton LP; Reynolds L
    S Afr J Commun Disord; 1991; 38():13-7. PubMed ID: 1670486
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Audiologic characteristics in a sample of recently-separated military Veterans: The Noise Outcomes in Servicemembers Epidemiology Study (NOISE Study).
    Gordon JS; Griest SE; Thielman EJ; Carlson KF; Helt WJ; Lewis MS; Blankenship C; Austin D; Theodoroff SM; Henry JA
    Hear Res; 2017 Jun; 349():21-30. PubMed ID: 27913314
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-frequency audiometry: a means for early diagnosis of noise-induced hearing loss.
    Mehrparvar AH; Mirmohammadi SJ; Ghoreyshi A; Mollasadeghi A; Loukzadeh Z
    Noise Health; 2011; 13(55):402-6. PubMed ID: 22122956
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High-speed drill noise and hearing: audiometric survey of 70 dentists.
    Forman-Franco B; Abramson AL; Stein T
    J Am Dent Assoc; 1978 Sep; 97(3):479-82. PubMed ID: 359623
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Noise Disturbance and Potential Hearing Loss Due to Exposure of Dental Equipment in Flemish Dentists.
    Dierickx M; Verschraegen S; Wierinck E; Willems G; van Wieringen A
    Int J Environ Res Public Health; 2021 May; 18(11):. PubMed ID: 34074041
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Laboratory evaluation of an optimised internet-based speech-in-noise test for occupational high-frequency hearing loss screening: Occupational Earcheck.
    Sheikh Rashid M; Leensen MCJ; de Laat JAPM; Dreschler WA
    Int J Audiol; 2017 Nov; 56(11):844-853. PubMed ID: 28587489
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [A study on abrupt high tone loss in perceptive hearing-impaired patients using a new audiological method--characteristics observed in the confusion chart and the width of uncertainty in DLSI].
    Hosoi H; Nishimae T; Murata K; Ohta F; Imaizumi S
    Nihon Jibiinkoka Gakkai Kaiho; 1986 Jun; 89(6):706-14. PubMed ID: 3761064
    [No Abstract]   [Full Text] [Related]  

  • 15. [Expert assessment of noise-induced hearing loss with special reference to differentiation between noise-induced damage and other degenerative diseases of the ear].
    Plath P
    HNO; 1992 Mar; 40(3):73-8. PubMed ID: 1577628
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Temporary shift of air conduction auditory threshold in extended ranges of high frequencies in persons exposed to noise].
    Majzel K; Gierek T
    Otolaryngol Pol; 1981; 35(2):149-55. PubMed ID: 7290707
    [No Abstract]   [Full Text] [Related]  

  • 17. [High-frequency hearing, an early indicator of the development of environmentally-induced inner ear damage].
    Dieroff HG
    Z Gesamte Hyg; 1986 Feb; 32(2):123-8. PubMed ID: 3962382
    [No Abstract]   [Full Text] [Related]  

  • 18. [Peculiarities of differential diagnosis of occupational neurosensory loss of hearing in the flight personnel of civilian aviation].
    Kozin OV
    Vestn Otorinolaringol; 2009; (6):26-9. PubMed ID: 20081791
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reliability of industrial audiometry as a screening method for incipient noise-induced hearing loss.
    Mets JT
    S Afr Med J; 1987 Jan; 71(1):35-9. PubMed ID: 3798291
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Extended high-frequency audiometry in subjects exposed to occupational noise.
    Korres GS; Balatsouras DG; Tzagaroulakis A; Kandiloros D; Ferekidis E
    B-ENT; 2008; 4(3):147-55. PubMed ID: 18949961
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.