  • 21. Low lateral thoracic site for cardiac implantable electronic device implantation: A viable alternative in patients with limited access options after infected device extraction.
    Liang JJ; Schaller RD; Modi DS; Enriquez A; Supple GE; Cooper JM
    Heart Rhythm; 2017 Oct; 14(10):1506-1514. PubMed ID: 28603001
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Infective endocarditis and risk of death after cardiac implantable electronic device implantation: a nationwide cohort study.
    Özcan C; Raunsø J; Lamberts M; Køber L; Lindhardt TB; Bruun NE; Laursen ML; Torp-Pedersen C; Gislason GH; Hansen ML
    Europace; 2017 Jun; 19(6):1007-1014. PubMed ID: 28073883
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Venous Obstruction in Asymptomatic Patients Undergoing First Implantation or Revision of a Cardiac Pacemaker or Implantable Cardioverter-Defibrillator: A Retrospective Single Center Analysis.
    Pieper CC; Weis V; Fimmers R; Rajab I; Linhart M; Schild HH; Nähle CP
    Rofo; 2015 Nov; 187(11):1029-35. PubMed ID: 26200569
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Multilevel Venous Obstruction in Patients with Cardiac Implantable Electronic Devices.
    Czajkowski M; Polewczyk A; Jacheć W; Kosior J; Nowosielecka D; Tułecki Ł; Stefańczyk P; Kutarski A
    Medicina (Kaunas); 2024 Feb; 60(2):. PubMed ID: 38399623
    [No Abstract]   [Full Text] [Related]  

  • 25. Laser lead extraction to facilitate cardiac implantable electronic device upgrade and revision in the presence of central venous obstruction.
    Sohal M; Williams S; Akhtar M; Shah A; Chen Z; Wright M; O'Neill M; Patel N; Hamid S; Cooklin M; Bucknall C; Bostock J; Gill J; Rinaldi CA
    Europace; 2014 Jan; 16(1):81-7. PubMed ID: 23794614
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Risk Factors and Long-Term Survival of Octogenarians and Nonagenarians Undergoing Transvenous Lead Extraction Procedures.
    Jacheć W; Polewczyk A; Segreti L; Bongiorni MG; Kutarski A
    Gerontology; 2021; 67(1):36-48. PubMed ID: 33242867
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Device-related infection among patients with pacemakers and implantable defibrillators: incidence, risk factors, and consequences.
    Nery PB; Fernandes R; Nair GM; Sumner GL; Ribas CS; Menon SM; Wang X; Krahn AD; Morillo CA; Connolly SJ; Healey JS
    J Cardiovasc Electrophysiol; 2010 Jul; 21(7):786-90. PubMed ID: 20102431
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Nontraditional surgical approaches for implantation of pacemaker and cardioverter defibrillator systems in patients with limited venous access.
    Jaroszewski DE; Altemose GT; Scott LR; Srivasthan K; Devaleria PA; Lackey J; Arabia FA
    Ann Thorac Surg; 2009 Jul; 88(1):112-6. PubMed ID: 19559206
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Survival in Women Versus Men Following Implantation of Pacemakers, Defibrillators, and Cardiac Resynchronization Therapy Devices in a Large, Nationwide Cohort.
    Varma N; Mittal S; Prillinger JB; Snell J; Dalal N; Piccini JP
    J Am Heart Assoc; 2017 May; 6(5):. PubMed ID: 28490521
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Implantable transvenous cardioverter-defibrillators.
    Bardy GH; Hofer B; Johnson G; Kudenchuk PJ; Poole JE; Dolack GL; Gleva M; Mitchell R; Kelso D
    Circulation; 1993 Apr; 87(4):1152-68. PubMed ID: 8462144
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Real-life outcome of implantable cardioverter-defibrillator and cardiac resynchronization defibrillator replacement/upgrade in a contemporary population: observations from the multicentre DECODE registry.
    Biffi M; Ammendola E; Menardi E; Parisi Q; Narducci ML; De Filippo P; Manzo M; Stabile G; Potenza DR; Zanon F; Quartieri F; Rillo M; Saporito D; Zacà V; Berisso MZ; Bertini M; Tumietto F; Malacrida M; Diemberger I
    Europace; 2019 Oct; 21(10):1527-1536. PubMed ID: 31209482
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Chronic Swelling Over Cardiac Implantable Electronic Device Sites: A Multicenter Case Series.
    Pothineni NVK; Bonilla CA; Ebrahim MA; Epstein AE; Garcia-Fernandez FJ; Guzman CE; Joshi H; Nasir JM; Singh A; Supple GE; Schaller RD
    Circ Arrhythm Electrophysiol; 2020 Dec; 13(12):e009253. PubMed ID: 33320698
    [No Abstract]   [Full Text] [Related]  

  • 33. Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysis.
    Polyzos KA; Konstantelias AA; Falagas ME
    Europace; 2015 May; 17(5):767-77. PubMed ID: 25926473
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Venous stenosis and occlusion in the presence of endocardial leads in patients referred for transvenous lead extraction.
    Boczar K; Zabek A; Haberka K; Debski M; Rydlewska A; Musial R; Lelakowski J; Malecka B
    Acta Cardiol; 2017 Feb; 72(1):61-67. PubMed ID: 28597736
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Incidence and predictors of subclavian vein obstruction following biventricular device implantation.
    Bulur S; Vural A; Yazıcı M; Ertaş G; Özhan H; Ural D
    J Interv Card Electrophysiol; 2010 Dec; 29(3):199-202. PubMed ID: 20890650
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Implantation of cardiac resynchronization therapy devices using three leads by cephalic vein dissection approach.
    Hadjis A; Proietti R; Essebag V
    Europace; 2017 Sep; 19(9):1514-1520. PubMed ID: 28340223
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Efficacy and safety of nitroglycerin for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation.
    Duan X; Ling F; Shen Y; Yang J; Xu HY; Tong XS
    Europace; 2013 Apr; 15(4):566-9. PubMed ID: 22848074
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Dual-chamber implantable cardioverter-defibrillator selection is associated with increased complication rates and mortality among patients enrolled in the NCDR implantable cardioverter-defibrillator registry.
    Dewland TA; Pellegrini CN; Wang Y; Marcus GM; Keung E; Varosy PD
    J Am Coll Cardiol; 2011 Aug; 58(10):1007-13. PubMed ID: 21867834
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Complications in recipients of cardioverter-defibrillator or cardiac resynchronization therapy: Insights from Silesian Center Defibrillator registry.
    Tajstra M; Gadula-Gacek E; Kurek A; Adamowicz-Czoch E; Olszowski D; Ostręga M; Ciślak A; Pyka Ł; Hawranek M; Lekston A; Poloński L; Gąsior M
    Cardiol J; 2017; 24(5):515-522. PubMed ID: 27734455
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Central venous occlusion is not an obstacle to device upgrade with the assistance of laser extraction.
    Gula LJ; Ames A; Woodburn A; Matkins J; McCormick M; Bell J; Sink D; McConville J; Epstein LM
    Pacing Clin Electrophysiol; 2005 Jul; 28(7):661-6. PubMed ID: 16008801
    [TBL] [Abstract][Full Text] [Related]  