These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
130 related articles for article (PubMed ID: 3053843)
1. Total inspiratory work with modern demand valve devices compared to continuous flow CPAP. Samodelov LF; Falke KJ Intensive Care Med; 1988; 14(6):632-9. PubMed ID: 3053843 [TBL] [Abstract][Full Text] [Related]
2. Imposed work of breathing and methods of triggering a demand-flow, continuous positive airway pressure system. Banner MJ; Blanch PB; Kirby RR Crit Care Med; 1993 Feb; 21(2):183-90. PubMed ID: 8428467 [TBL] [Abstract][Full Text] [Related]
3. Inspiratory work imposed by continuous positive airway pressure (CPAP) machines: the effect of CPAP level and endotracheal tube size. Moran JL; Homan S; O'Fathartaigh M; Jackson M; Leppard P Intensive Care Med; 1992; 18(3):148-54. PubMed ID: 1644962 [TBL] [Abstract][Full Text] [Related]
4. Effect of low-level PEEP on inspiratory work of breathing in intubated patients, both with healthy lungs and with COPD. Sydow M; Golisch W; Buscher H; Zinserling J; Crozier TA; Burchardi H Intensive Care Med; 1995 Nov; 21(11):887-95. PubMed ID: 8636520 [TBL] [Abstract][Full Text] [Related]
5. Pressure support compensation for inspiratory work due to endotracheal tubes and demand continuous positive airway pressure. Fiastro JF; Habib MP; Quan SF Chest; 1988 Mar; 93(3):499-505. PubMed ID: 3277803 [TBL] [Abstract][Full Text] [Related]
6. Efficacy of pressure support in compensating for apparatus work. Bersten AD; Rutten AJ; Vedig AE Anaesth Intensive Care; 1993 Feb; 21(1):67-71. PubMed ID: 8447610 [TBL] [Abstract][Full Text] [Related]
7. [Quantitative comparison of ventilator-induced work during simulated CPAP in eight demand-flow valve ventilators]. Nishimura M; Imanaka H; Taenaka N; Yoshiya I; Takezawa J Masui; 1989 Aug; 38(8):1017-29. PubMed ID: 2681861 [TBL] [Abstract][Full Text] [Related]
8. Ventilator-CPAP with the Siemens Servo 900C compared with continuous flow-CPAP in intubated patients: effect on work of breathing. Aerts JG; van den Berg B; Bogaard JM Anaesth Intensive Care; 1997 Oct; 25(5):487-92. PubMed ID: 9352760 [TBL] [Abstract][Full Text] [Related]
9. Inspiratory muscle work of breathing during flow-by, demand-flow, and continuous-flow systems in patients with chronic obstructive pulmonary disease. Sassoon CS; Lodia R; Rheeman CH; Kuei JH; Light RW; Mahutte CK Am Rev Respir Dis; 1992 May; 145(5):1219-22. PubMed ID: 1586070 [TBL] [Abstract][Full Text] [Related]
10. Tracheal pressure triggering a demand-flow continuous positive airway pressure system decreases patient work of breathing. Messinger G; Banner MJ Crit Care Med; 1996 Nov; 24(11):1829-34. PubMed ID: 8917033 [TBL] [Abstract][Full Text] [Related]
11. Using tracheal pressure to trigger the ventilator and control airway pressure during continuous positive airway pressure decreases work of breathing. Messinger G; Banner MJ; Blanch PB; Layon AJ Chest; 1995 Aug; 108(2):509-14. PubMed ID: 7634891 [TBL] [Abstract][Full Text] [Related]
13. Characteristics of the ventilator pressure- and flow-trigger variables. Sassoon CS; Gruer SE Intensive Care Med; 1995 Feb; 21(2):159-68. PubMed ID: 7775698 [TBL] [Abstract][Full Text] [Related]
14. Physiologic effects of transtracheal open ventilation in postextubation patients with high upper airway resistance. Uchiyama A; Mori T; Imanaka H; Nishimura M Crit Care Med; 2001 Sep; 29(9):1694-700. PubMed ID: 11546967 [TBL] [Abstract][Full Text] [Related]
15. Work of breathing, inspiratory flow response, and expiratory resistance during continuous positive airway pressure with the ventilators EVITA-2, EVITA-4 and SV 300. Calzia E; Lindner KH; Stahl W; Martin A; Radermacher P; Georgieff M Intensive Care Med; 1998 Sep; 24(9):931-8. PubMed ID: 9803329 [TBL] [Abstract][Full Text] [Related]
16. Respiratory muscle performance, pulmonary mechanics, and gas exchange between the BiPAP S/T-D system and the Servo Ventilator 900C with bilevel positive airway pressure ventilation following gradual pressure support weaning. Patel RG; Petrini MF Chest; 1998 Nov; 114(5):1390-6. PubMed ID: 9824020 [TBL] [Abstract][Full Text] [Related]
17. Superimposed inspiratory work of the Siemens Servo 300 ventilator during continuous positive airway pressure. Tan IK; Bhatt SB; Tam YH; Buckley TA; Oh TE Intensive Care Med; 1995 Dec; 21(12):1023-6. PubMed ID: 8750128 [TBL] [Abstract][Full Text] [Related]
18. Inspiratory work of breathing on flow-by and demand-flow continuous positive airway pressure. Sassoon CS; Giron AE; Ely EA; Light RW Crit Care Med; 1989 Nov; 17(11):1108-14. PubMed ID: 2676347 [TBL] [Abstract][Full Text] [Related]