  • 1. Total inspiratory work with modern demand valve devices compared to continuous flow CPAP.
    Samodelov LF; Falke KJ
    Intensive Care Med; 1988; 14(6):632-9. PubMed ID: 3053843
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Imposed work of breathing and methods of triggering a demand-flow, continuous positive airway pressure system.
    Banner MJ; Blanch PB; Kirby RR
    Crit Care Med; 1993 Feb; 21(2):183-90. PubMed ID: 8428467
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Inspiratory work imposed by continuous positive airway pressure (CPAP) machines: the effect of CPAP level and endotracheal tube size.
    Moran JL; Homan S; O'Fathartaigh M; Jackson M; Leppard P
    Intensive Care Med; 1992; 18(3):148-54. PubMed ID: 1644962
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of low-level PEEP on inspiratory work of breathing in intubated patients, both with healthy lungs and with COPD.
    Sydow M; Golisch W; Buscher H; Zinserling J; Crozier TA; Burchardi H
    Intensive Care Med; 1995 Nov; 21(11):887-95. PubMed ID: 8636520
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pressure support compensation for inspiratory work due to endotracheal tubes and demand continuous positive airway pressure.
    Fiastro JF; Habib MP; Quan SF
    Chest; 1988 Mar; 93(3):499-505. PubMed ID: 3277803
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Efficacy of pressure support in compensating for apparatus work.
    Bersten AD; Rutten AJ; Vedig AE
    Anaesth Intensive Care; 1993 Feb; 21(1):67-71. PubMed ID: 8447610
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Quantitative comparison of ventilator-induced work during simulated CPAP in eight demand-flow valve ventilators].
    Nishimura M; Imanaka H; Taenaka N; Yoshiya I; Takezawa J
    Masui; 1989 Aug; 38(8):1017-29. PubMed ID: 2681861
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ventilator-CPAP with the Siemens Servo 900C compared with continuous flow-CPAP in intubated patients: effect on work of breathing.
    Aerts JG; van den Berg B; Bogaard JM
    Anaesth Intensive Care; 1997 Oct; 25(5):487-92. PubMed ID: 9352760
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Inspiratory muscle work of breathing during flow-by, demand-flow, and continuous-flow systems in patients with chronic obstructive pulmonary disease.
    Sassoon CS; Lodia R; Rheeman CH; Kuei JH; Light RW; Mahutte CK
    Am Rev Respir Dis; 1992 May; 145(5):1219-22. PubMed ID: 1586070
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tracheal pressure triggering a demand-flow continuous positive airway pressure system decreases patient work of breathing.
    Messinger G; Banner MJ
    Crit Care Med; 1996 Nov; 24(11):1829-34. PubMed ID: 8917033
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Using tracheal pressure to trigger the ventilator and control airway pressure during continuous positive airway pressure decreases work of breathing.
    Messinger G; Banner MJ; Blanch PB; Layon AJ
    Chest; 1995 Aug; 108(2):509-14. PubMed ID: 7634891
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Continuous positive airway pressure reduces work of breathing and dyspnea during weaning from mechanical ventilation in severe chronic obstructive pulmonary disease.
    Petrof BJ; Legaré M; Goldberg P; Milic-Emili J; Gottfried SB
    Am Rev Respir Dis; 1990 Feb; 141(2):281-9. PubMed ID: 2405757
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characteristics of the ventilator pressure- and flow-trigger variables.
    Sassoon CS; Gruer SE
    Intensive Care Med; 1995 Feb; 21(2):159-68. PubMed ID: 7775698
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Physiologic effects of transtracheal open ventilation in postextubation patients with high upper airway resistance.
    Uchiyama A; Mori T; Imanaka H; Nishimura M
    Crit Care Med; 2001 Sep; 29(9):1694-700. PubMed ID: 11546967
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Work of breathing, inspiratory flow response, and expiratory resistance during continuous positive airway pressure with the ventilators EVITA-2, EVITA-4 and SV 300.
    Calzia E; Lindner KH; Stahl W; Martin A; Radermacher P; Georgieff M
    Intensive Care Med; 1998 Sep; 24(9):931-8. PubMed ID: 9803329
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Respiratory muscle performance, pulmonary mechanics, and gas exchange between the BiPAP S/T-D system and the Servo Ventilator 900C with bilevel positive airway pressure ventilation following gradual pressure support weaning.
    Patel RG; Petrini MF
    Chest; 1998 Nov; 114(5):1390-6. PubMed ID: 9824020
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Superimposed inspiratory work of the Siemens Servo 300 ventilator during continuous positive airway pressure.
    Tan IK; Bhatt SB; Tam YH; Buckley TA; Oh TE
    Intensive Care Med; 1995 Dec; 21(12):1023-6. PubMed ID: 8750128
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Inspiratory work of breathing on flow-by and demand-flow continuous positive airway pressure.
    Sassoon CS; Giron AE; Ely EA; Light RW
    Crit Care Med; 1989 Nov; 17(11):1108-14. PubMed ID: 2676347
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of imposed resistance on tidal volume with 5 neonatal nasal continuous positive airway pressure systems.
    Cook SE; Fedor KL; Chatburn RL
    Respir Care; 2010 May; 55(5):544-8. PubMed ID: 20420723
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effect of ventilator performance on airway pressure release ventilation: a model lung study.
    Yoshida T; Uchiyama A; Mashimo T; Fujino Y
    Anesth Analg; 2011 Sep; 113(3):529-33. PubMed ID: 21519042
    [TBL] [Abstract][Full Text] [Related]  