  • 1. Cardiac erosion after catheter closure of atrial septal defect: Septal malalignment may be a novel risk factor for erosion.
    Kijima Y; Akagi T; Nakagawa K; Promphan W; Toh N; Nakamura K; Sano S; Ito H
    J Cardiol Cases; 2014 Apr; 9(4):134-137. PubMed ID: 30546783
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Relative Risk Factors for Cardiac Erosion Following Transcatheter Closure of Atrial Septal Defects: A Case-Control Study.
    McElhinney DB; Quartermain MD; Kenny D; Alboliras E; Amin Z
    Circulation; 2016 May; 133(18):1738-46. PubMed ID: 27002094
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Risk Factors and Predictors of Cardiac Erosion Discovered from 12 Japanese Patients Who Developed Erosion After Atrial Septal Defect Closure Using Amplatzer Septal Occluder.
    Kitano M; Yazaki S; Sugiyama H; Ohtsuki SI; Tomita H
    Pediatr Cardiol; 2020 Feb; 41(2):297-308. PubMed ID: 31732763
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Echocardiographic predictors of cardiac erosion after Amplatzer septal occluder placement.
    Amin Z
    Catheter Cardiovasc Interv; 2014 Jan; 83(1):84-92. PubMed ID: 24038861
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Aortic erosion occurring in over 5 years after Amplatzer septal Occluder implantation for secundum atrial septal defect: a case report.
    Onakatomi Y; Asou T; Takeda Y; Ueda H; Goda M; Masuda M
    J Cardiothorac Surg; 2019 Sep; 14(1):159. PubMed ID: 31492164
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A life-saving case of cardiopulmonary arrest with cardiac tamponade caused by erosion 6 years after percutaneous atrial septal defect closure: a case report.
    Kobayashi T; Watanabe T; Fu H; Yohei O; Goto T
    J Cardiothorac Surg; 2021 May; 16(1):137. PubMed ID: 34020682
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Atrio-aortic erosion caused by Amplatzer Atrial Septal Occluder - a case report.
    Kamla CE; Buech J; Doldi PM; Hagl C; Juchem G; Dashkevich A
    J Cardiothorac Surg; 2021 Mar; 16(1):36. PubMed ID: 33743762
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An asymptomatic child of pre-perforation erosion after transcatheter closure of atrial septal defect.
    Zhang WL; Liang F
    J Cardiothorac Surg; 2021 Sep; 16(1):263. PubMed ID: 34537071
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The 'aortic rim' recount: embolization of interatrial septal occluder into the main pulmonary artery bifurcation after atrial septal defect closure.
    Misra M; Sadiq A; Namboodiri N; Karunakaran J
    Interact Cardiovasc Thorac Surg; 2007 Jun; 6(3):384-6. PubMed ID: 17669873
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new "tool" for transcatheter atrial defect closure: the St. Jude SL2™ sheath.
    Lee S; Sutton N; Lopez L; Farooqi K; Mahgerefteh J; Blancas I; Pass RH
    Catheter Cardiovasc Interv; 2012 Aug; 80(2):177-81. PubMed ID: 22431253
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Coronary Sinus Defect Following Transcatheter Closure of ASD Using Amplatzer Septal Occluder: Potential Erosion by the Device.
    Mohammad Nijres B; Al-Kubaisi M; Bokowski J; Abdulla RI; Awad S
    Pediatr Cardiol; 2017 Jun; 38(5):1084-1086. PubMed ID: 28396933
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk.
    Amin Z; Hijazi ZM; Bass JL; Cheatham JP; Hellenbrand WE; Kleinman CS
    Catheter Cardiovasc Interv; 2004 Dec; 63(4):496-502. PubMed ID: 15558755
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Late tissue erosion after transcatheter closure of an atrial septal defect.
    Mendirichaga R; Smairat RA; Sancassani R
    Catheter Cardiovasc Interv; 2017 Feb; 89(3):502-504. PubMed ID: 26527464
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Live/Real time three-dimensional transesophageal echocardiography in percutaneous closure of atrial septal defects.
    Bhaya M; Mutluer FO; Mahan E; Mahan L; Hsiung MC; Yin WH; Wei J; Tsai SK; Zhao GY; Yin WH; Pradhan M; Beniwal R; Joshi D; Nabavizadeh F; Singh A; Nanda NC
    Echocardiography; 2013 Mar; 30(3):345-53. PubMed ID: 23336391
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Embolization of an Atrial Septal Defect Occluder Device Into the Left Ventricle.
    Hierlmeier BJ; Ostrovsky G; Zarth M
    Cureus; 2020 Nov; 12(11):e11417. PubMed ID: 33312813
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Three-dimensional echocardiographic demonstration of aortic wall erosion after percutaneous atrial septal defect closure.
    Mohamed AM; Türkmen I; Abdrabou MMM; Kemaloğlu Oz T
    J Clin Ultrasound; 2019 Jul; 47(6):384-386. PubMed ID: 30729539
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Percutaneous atrial septal occluder devices and cardiac erosion: a review of the literature.
    Crawford GB; Brindis RG; Krucoff MW; Mansalis BP; Carroll JD
    Catheter Cardiovasc Interv; 2012 Aug; 80(2):157-67. PubMed ID: 22552868
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pericardial tamponade due to erosion of a Figulla Flex II device after closure of an atrial septal defect.
    Abe T; Tsukano S; Tosaka Y
    Catheter Cardiovasc Interv; 2019 Dec; 94(7):1003-1005. PubMed ID: 31194277
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical results of large secundum atrial septal defect closure in adult using percutaneous transcatheter Cocoon atrial septal occluder.
    Lairakdomrong K; Srimahachota S; Lertsapcharoen P; Chaipromprasit J; Boonyaratavej S; Kaewsukkho P
    J Med Assoc Thai; 2013 Sep; 96(9):1127-34. PubMed ID: 24163987
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Delayed Left Atrial Perforation Associated with Erosion After Device Closure of an Atrial Septal Defect.
    Kim JS; Yeom SY; Kim SH; Choi JW; Kim KH
    Korean J Thorac Cardiovasc Surg; 2017 Apr; 50(2):110-113. PubMed ID: 28382270