These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
164 related articles for article (PubMed ID: 30554503)
41. A GAMOS plug-in for GEANT4 based Monte Carlo simulation of radiation-induced light transport in biological media. Glaser AK; Kanick SC; Zhang R; Arce P; Pogue BW Biomed Opt Express; 2013 May; 4(5):741-59. PubMed ID: 23667790 [TBL] [Abstract][Full Text] [Related]
42. Diffuse light propagation in biological media by a time-domain parabolic simplified spherical harmonics approximation with ray-divergence effects. Bouza Domínguez J; Bérubé-Lauzière Y Appl Opt; 2010 Mar; 49(8):1414-29. PubMed ID: 20220899 [TBL] [Abstract][Full Text] [Related]
43. Graphics processing units-accelerated adaptive nonlocal means filter for denoising three-dimensional Monte Carlo photon transport simulations. Yuan Y; Yu L; Doğan Z; Fang Q J Biomed Opt; 2018 Nov; 23(12):1-9. PubMed ID: 30499265 [TBL] [Abstract][Full Text] [Related]
44. Modeling of diffuse reflectance of light in heterogeneous biological tissue to analysis of the effects of multiple scattering on reflectance pulse oximetry. Mehrabi M; Setayeshi S; Ardehali SH; Arabalibeik H J Biomed Opt; 2017 Jan; 22(1):15004. PubMed ID: 28114451 [TBL] [Abstract][Full Text] [Related]
45. Two-step verification method for Monte Carlo codes in biomedical optics applications. Sassaroli A; Tommasi F; Cavalieri S; Fini L; Liemert A; Kienle A; Binzoni T; Martelli F J Biomed Opt; 2022 Apr; 27(8):. PubMed ID: 35445592 [TBL] [Abstract][Full Text] [Related]
46. Modeling the tight focusing of beams in absorbing media with Monte Carlo simulations. Brandes AR; Elmaklizi A; Akarçay HG; Kienle A J Biomed Opt; 2014; 19(11):115003. PubMed ID: 25393966 [TBL] [Abstract][Full Text] [Related]
47. Graphics processing unit-accelerated mesh-based Monte Carlo photon transport simulations. Fang Q; Yan S J Biomed Opt; 2019 Nov; 24(11):1-6. PubMed ID: 31746154 [TBL] [Abstract][Full Text] [Related]
48. Hybrid radiative-transfer-diffusion model for optical tomography. Tarvainen T; Vauhkonen M; Kolehmainen V; Kaipio JP Appl Opt; 2005 Feb; 44(6):876-86. PubMed ID: 15751677 [TBL] [Abstract][Full Text] [Related]
49. Parallelized Monte Carlo software to efficiently simulate the light propagation in arbitrarily shaped objects and aligned scattering media. Zoller CJ; Hohmann A; Foschum F; Geiger S; Geiger M; Ertl TP; Kienle A J Biomed Opt; 2018 Jun; 23(6):1-12. PubMed ID: 29935015 [TBL] [Abstract][Full Text] [Related]
50. Hardware acceleration of a Monte Carlo simulation for photodynamic therapy [corrected] treatment planning. Lo WC; Redmond K; Luu J; Chow P; Rose J; Lilge L J Biomed Opt; 2009; 14(1):014019. PubMed ID: 19256707 [TBL] [Abstract][Full Text] [Related]
51. Monte Carlo Simulations of Heat Deposition During Photothermal Skin Cancer Therapy Using Nanoparticles. Jeynes JCG; Wordingham F; Moran LJ; Curnow A; Harries TJ Biomolecules; 2019 Aug; 9(8):. PubMed ID: 31387293 [TBL] [Abstract][Full Text] [Related]
52. Monte Carlo methods for light propagation in biological tissues. Vinckenbosch L; Lacaux C; Tindel S; Thomassin M; Obara T Math Biosci; 2015 Nov; 269():48-60. PubMed ID: 26362232 [TBL] [Abstract][Full Text] [Related]
53. Coupled radiative transfer equation and diffusion approximation model for photon migration in turbid medium with low-scattering and non-scattering regions. Tarvainen T; Vauhkonen M; Kolehmainen V; Arridge SR; Kaipio JP Phys Med Biol; 2005 Oct; 50(20):4913-30. PubMed ID: 16204880 [TBL] [Abstract][Full Text] [Related]
54. Modelling the distribution of laser light in port-wine stains with the Monte Carlo method. Smithies DJ; Butler PH Phys Med Biol; 1995 May; 40(5):701-31. PubMed ID: 7652003 [TBL] [Abstract][Full Text] [Related]
55. Simulation of polarization-sensitive optical coherence tomography images by a Monte Carlo method. Meglinski I; Kirillin M; Kuzmin V; Myllylä R Opt Lett; 2008 Jul; 33(14):1581-3. PubMed ID: 18628804 [TBL] [Abstract][Full Text] [Related]
56. Derivation of a Monte Carlo method for modeling heterodyne detection in optical coherence tomography systems. Tycho A; Jørgensen TM; Yura HT; Andersen PE Appl Opt; 2002 Nov; 41(31):6676-91. PubMed ID: 12412659 [TBL] [Abstract][Full Text] [Related]
57. Simulation of skin reflectance images using 3D tissue modeling and multispectral Monte Carlo light propagation. Paquit VC; Mériaudeau F; Price JR; Tobin KW Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():447-50. PubMed ID: 19162689 [TBL] [Abstract][Full Text] [Related]
58. White Monte Carlo for time-resolved photon migration. Alerstam E; Andersson-Engels S; Svensson T J Biomed Opt; 2008; 13(4):041304. PubMed ID: 19021312 [TBL] [Abstract][Full Text] [Related]
59. A comparison between transport and diffusion calculations using a finite element-spherical harmonics radiation transport method. Aydin ED; de Oliveira CR; Goddard AJ Med Phys; 2002 Sep; 29(9):2013-23. PubMed ID: 12349922 [TBL] [Abstract][Full Text] [Related]
60. Light propagation in multilayered scattering media beyond the diffusive regime. Elaloufi R; Arridge S; Pierrat R; Carminati R Appl Opt; 2007 May; 46(13):2528-39. PubMed ID: 17429467 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]