These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

215 related articles for article (PubMed ID: 30554895)

  • 1. Biomechanical investigation of tibial tubercle osteotomy fixed with various screw configurations.
    Chang CW; Chen YN; Li CT; Chung CR; Tseng CC; Chang CH; Peng YT
    Injury; 2019 Feb; 50(2):263-271. PubMed ID: 30554895
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Finite element study of the effects of fragment shape and screw configuration on the mechanical behavior of tibial tubercle osteotomy.
    Chang CW; Chen YN; Li CT; Chung CR; Chang CH; Peng YT
    J Orthop Surg (Hong Kong); 2019; 27(3):2309499019861145. PubMed ID: 31311422
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Gap between the fragment and the tibia affects the stability of tibial tubercle osteotomy: A finite element study.
    Chen YN; Chang CW; Chang CH; Chung CR; Li CT; Peng YT
    Med Eng Phys; 2019 Jun; 68():57-64. PubMed ID: 30975631
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of four different screw configurations for the fixation of Fulkerson osteotomy: a finite element analysis.
    Aykanat F; Kose O; Guneri B; Celik HK; Cakar A; Tasatan E; Ulmeanu ME
    J Orthop Traumatol; 2023 Jun; 24(1):30. PubMed ID: 37358664
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical investigation of the type and configuration of screws used in high tibial osteotomy with titanium locking plate and screw fixation.
    Chen YN; Chang CW; Li CT; Chen CH; Chung CR; Chang CH; Peng YT
    J Orthop Surg Res; 2019 Jan; 14(1):35. PubMed ID: 30691494
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical effect of the configuration of screw hole style on locking plate fixation in proximal humerus fracture with a simulated gap: A finite element analysis.
    Zhang YK; Wei HW; Lin KP; Chen WC; Tsai CL; Lin KJ
    Injury; 2016 Jun; 47(6):1191-5. PubMed ID: 26975793
    [TBL] [Abstract][Full Text] [Related]  

  • 7. How to fix a tibial tubercle osteotomy with distalisation: A finite element analysis.
    Guneri B; Kose O; Celik HK; Cakar A; Tasatan E; Rennie AEW
    Knee; 2022 Aug; 37():132-142. PubMed ID: 35779431
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reinforcement strategy for medial open-wedge high tibial osteotomy: a finite element evaluation of the additional opposite screw technique and bone grafts.
    Zhao XW; Fan ZR; Ma JX; Ma XL; Wang Y; Bai HH; Lu B; Sun L
    Comput Methods Programs Biomed; 2022 Jan; 213():106523. PubMed ID: 34808530
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of theoretical fixation stability of three devices employed in medial opening wedge high tibial osteotomy: a finite element analysis.
    Golovakhа ML; Orljanski W; Benedetto KP; Panchenko S; Büchler P; Henle P; Aghayev E
    BMC Musculoskelet Disord; 2014 Jul; 15():230. PubMed ID: 25012591
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical effects of screw orientation and plate profile on tibial condylar valgus osteotomy - Finite-element analysis.
    Cheng CT; Luo CA; Chen YC
    Comput Methods Biomech Biomed Engin; 2020 Sep; 23(12):906-913. PubMed ID: 32478579
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Proximal bone block with distal screw trajectory improves mechanical stability during distalization tibial tubercle osteotomy.
    Uppstrom TJ; Cash BM; Jahandar A; Fletcher C; Nguyen JT; Maher SA; Strickland SM; Gomoll AH
    Knee Surg Sports Traumatol Arthrosc; 2023 Oct; 31(10):4239-4245. PubMed ID: 37300701
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Placement-induced effects on high tibial osteotomized construct - biomechanical tests and finite-element analyses.
    Luo CA; Hwa SY; Lin SC; Chen CM; Tseng CS
    BMC Musculoskelet Disord; 2015 Sep; 16():235. PubMed ID: 26337985
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mechanical performance and implications on bone healing of different screw configurations for plate fixation of diaphyseal tibia fractures: a computational study.
    Travascio F; Buller LT; Milne E; Latta L
    Eur J Orthop Surg Traumatol; 2021 Jan; 31(1):121-130. PubMed ID: 32725431
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of fixation methods after anteromedialization osteotomy of the tibial tubercle for patellar instability.
    Warner BT; Kamath GV; Spang JT; Weinhold PS; Creighton RA
    Arthroscopy; 2013 Oct; 29(10):1628-34. PubMed ID: 23993053
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of oblique triangular configuration and inverted equilateral triangular configuration of three cannulated screws in treating unstable femoral neck fracture: A finite element analysis.
    Zhang RY; Li JT; Zhao JX; Zhao Z; Zhang LC; Yun C; Su XY; Tang PF
    Injury; 2022 Feb; 53(2):353-361. PubMed ID: 34801246
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Proximal Screw Configuration Alters Peak Plate Strain Without Changing Construct Stiffness in Comminuted Supracondylar Femur Fractures.
    McLachlin S; Kreder H; Ng M; Jenkinson R; Whyne C; Larouche J
    J Orthop Trauma; 2017 Dec; 31(12):e418-e424. PubMed ID: 28902085
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of Fixation Techniques in Oblique and Biplanar Chevron Medial Malleolar Osteotomies; a Finite Element Analysis.
    Levent A; Yapti M; Celik HK; Kose O; Kilicaslan OF; Rennie AEW
    J Foot Ankle Surg; 2022; 61(2):253-258. PubMed ID: 34456133
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Screw configuration in proximal humerus plating has a significant impact on fixation failure risk predicted by finite element models.
    Fletcher JWA; Windolf M; Richards RG; Gueorguiev B; Varga P
    J Shoulder Elbow Surg; 2019 Sep; 28(9):1816-1823. PubMed ID: 31036421
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ability of modern distal tibia plates to stabilize comminuted pilon fracture fragments: Is dual plate fixation necessary?
    Penny P; Swords M; Heisler J; Cien A; Sands A; Cole P
    Injury; 2016 Aug; 47(8):1761-9. PubMed ID: 27264277
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Role of an additional third screw in the fixation of transverse patellar fracture with two parallel cannulated screw and anterior wire.
    Chang CW; Chen CH; Li CT; Chen YN; Yang TH; Chang CJ; Chang CH
    BMC Musculoskelet Disord; 2020 Nov; 21(1):752. PubMed ID: 33189156
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.