199 related articles for article (PubMed ID: 30560360)
21. Office-based Ultrasound-guided Renal Core Biopsy Is Safe and Efficacious in the Management of Small Renal Masses. Dave CN; Seifman B; Chennamsetty A; Frontera R; Faraj K; Nelson R; Lucido C; Schervish EW Urology; 2017 Apr; 102():26-30. PubMed ID: 28024966 [TBL] [Abstract][Full Text] [Related]
22. Comparative study on efficacy and safety of ultrasound guided transoral and transcutaneous core needle biopsy in patients with oral masses. Wei T; Lu M; Li J; Hu Z; Li T; Cheng X; Wang L; Pu W BMC Med Imaging; 2022 Apr; 22(1):65. PubMed ID: 35392835 [TBL] [Abstract][Full Text] [Related]
23. Complication rate and diagnostic yield of percutaneous native kidney biopsies: A 10-year experience at a Tertiary Care Hospital in Pakistan. Yaqub S; Ahmed N; Fatima U; Maqbool A; Ashif W; Hussain SA Saudi J Kidney Dis Transpl; 2017; 28(4):891-897. PubMed ID: 28748893 [TBL] [Abstract][Full Text] [Related]
24. Imaging-Related Risk Factors for Bleeding Complications of US-Guided Native Renal Biopsy: A Propensity Score Matching Analysis. Li Q; Lin X; Zhang X; Samir AE; Arellano RS J Vasc Interv Radiol; 2019 Jan; 30(1):87-94. PubMed ID: 30527649 [TBL] [Abstract][Full Text] [Related]
26. Comparative analysis of ultrasound-guided percutaneous biopsy of native kidneys in children and adults using the free-flank supine antero-lateral decubitus positioning. Ravizzini PIC; Lino H; Fleury EFC; Rangel DA; de Toledo LGM Abdom Radiol (NY); 2024 May; 49(5):1638-1645. PubMed ID: 38658444 [TBL] [Abstract][Full Text] [Related]
27. Diagnostic yield and safety of ultrasound-guided bowel mass biopsies in children. Minhas K; Roebuck DJ; Barnacle A; De Coppi P; Sebire N; Patel PA Pediatr Radiol; 2019 Dec; 49(13):1809-1815. PubMed ID: 31302738 [TBL] [Abstract][Full Text] [Related]
28. ARFI-based tissue elasticity quantification and kidney graft dysfunction: first clinical experiences. Stock KF; Klein BS; Cong MT; Regenbogen C; Kemmner S; Büttner M; Wagenpfeil S; Matevossian E; Renders L; Heemann U; Küchle C Clin Hemorheol Microcirc; 2011; 49(1-4):527-35. PubMed ID: 22214724 [TBL] [Abstract][Full Text] [Related]
29. Role of protocol biopsy in early graft dysfunction in renal transplant recipient. Islam SF; Hadiuzzaman KM; Islam MN; Khanam A; Faroque MO; Ahmed AH Mymensingh Med J; 2014 Apr; 23(2):286-9. PubMed ID: 24858156 [TBL] [Abstract][Full Text] [Related]
30. Safety and Accuracy of Percutaneous Image-Guided Core Biopsy of the Spleen. Olson MC; Atwell TD; Harmsen WS; Konrad A; King RL; Lin Y; Wall DJ AJR Am J Roentgenol; 2016 Mar; 206(3):655-9. PubMed ID: 26901024 [TBL] [Abstract][Full Text] [Related]
31. Utility and Safety of Repeated Ultrasound-Guided Core Needle Biopsy of Focal Liver Masses. Kim JS; Won HJ; Lee SJ; Kim SY; Shin YM; Kim PN J Ultrasound Med; 2018 Feb; 37(2):447-452. PubMed ID: 28850692 [TBL] [Abstract][Full Text] [Related]
33. Comparison of the Diagnostic Efficacy of Ultrasound-Guided Core Needle Biopsy With 18- Versus 20-Gauge Needles for Thyroid Nodules. Ahn HS; Seo M; Ha SM; Kim HS J Ultrasound Med; 2018 Nov; 37(11):2565-2574. PubMed ID: 29575135 [TBL] [Abstract][Full Text] [Related]
34. Percutaneous Ultrasound-Guided Kidney Transplant Biopsy Outcomes: From the Nephrologist to the Radiologist Standpoint. Mattiazzi AD; Cortesi CA; Patil RJ; Carias Martinez KG; Sedki M; Cabeza Rivera FH; Ruiz P; Salsamendi JT; Guerra G Kidney360; 2022 Oct; 3(10):1746-1753. PubMed ID: 36514719 [TBL] [Abstract][Full Text] [Related]
35. A new technique of ultrasound guided percutaneous renal biopsy by perforated probe and perpendicular needle trajectory. Brardi S; Cevenini G; Bonadio AG Arch Ital Urol Androl; 2018 Mar; 90(1):29-33. PubMed ID: 29633796 [TBL] [Abstract][Full Text] [Related]
36. Safety of Outpatient Kidney Biopsies. Šimunov B; Gunjača M; Čingel B; Škegro D; Knotek M Nephron; 2018; 138(4):275-279. PubMed ID: 29301131 [TBL] [Abstract][Full Text] [Related]
38. Safety and efficacy of fluoroscopic versus ultrasound guidance for core liver biopsies in potential living related liver transplant donors: preliminary results. Saad WE; Ryan CK; Davies MG; Fultz P; Rubens DJ; Patel NC; Sahler LG; Lee DE; Kitanosono T; Sasson T; Waldman DL J Vasc Interv Radiol; 2006 Aug; 17(8):1307-12. PubMed ID: 16923977 [TBL] [Abstract][Full Text] [Related]
39. Accuracy and effectiveness of ultrasound-guided core-needle biopsy in the diagnosis of focal lesions in the salivary glands. Del Cura JL; Coronado G; Zabala R; Korta I; López I Eur Radiol; 2018 Jul; 28(7):2934-2941. PubMed ID: 29387922 [TBL] [Abstract][Full Text] [Related]
40. Transfemoral liver biopsy using a Quick-Core biopsy needle system in living donor liver transplantation recipients. Li FQ; Ko GY; Sung KB; Gwon DI; Ko HK; Kim JW; Yu E Liver Transpl; 2014 Oct; 20(10):1178-84. PubMed ID: 24916429 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]