133 related articles for article (PubMed ID: 30569898)
1. Increased radiation dose and projected radiation-related lifetime cancer risk in patients with obesity due to projection radiography.
Alqahtani SJM; Welbourn R; Meakin JR; Palfrey RM; Rimes SJ; Thomson K; Knapp KM
J Radiol Prot; 2019 Jan; 39(1):38-53. PubMed ID: 30569898
[TBL] [Abstract][Full Text] [Related]
2. PATIENT DOSE IN DIGITAL RADIOGRAPHY UTILISING BMI CLASSIFICATION.
Metaxas VI; Messaris GA; Lekatou AN; Petsas TG; Panayiotakis GS
Radiat Prot Dosimetry; 2019 Aug; 184(2):155-167. PubMed ID: 30452729
[TBL] [Abstract][Full Text] [Related]
3. Obesity is a major determinant of radiation dose in patients undergoing pulmonary vein isolation for atrial fibrillation.
Ector J; Dragusin O; Adriaenssens B; Huybrechts W; Willems R; Ector H; Heidbüchel H
J Am Coll Cardiol; 2007 Jul; 50(3):234-42. PubMed ID: 17631216
[TBL] [Abstract][Full Text] [Related]
4. Cumulative radiation exposure and associated cancer risk estimates for scoliosis patients: Impact of repetitive full spine radiography.
Law M; Ma WK; Lau D; Chan E; Yip L; Lam W
Eur J Radiol; 2016 Mar; 85(3):625-8. PubMed ID: 26860676
[TBL] [Abstract][Full Text] [Related]
5. An Estimation of Lifetime Fatal Carcinogenesis Risk Attributable to Radiation Exposure in the First Year Following Polytrauma: A Major Trauma Center's Experience Over 10 Years.
Howard A; West R; Iball G; Panteli M; Pandit H; Giannoudis PV
J Bone Joint Surg Am; 2019 Aug; 101(15):1375-1380. PubMed ID: 31393428
[TBL] [Abstract][Full Text] [Related]
6. Lifetime attributable risk of cancer incidence and mortality in routine digital radiology procedures.
Zangeneh M; Deevband MR; Mohsenzadeh B
Clin Imaging; 2020 Nov; 67():226-236. PubMed ID: 32871427
[TBL] [Abstract][Full Text] [Related]
7. The impact of body mass index on patient radiation dose in general radiography.
Dolenc L; Petrinjak B; Mekiš N; Škrk D
J Radiol Prot; 2022 Nov; 42(4):. PubMed ID: 36319605
[TBL] [Abstract][Full Text] [Related]
8. PATIENT DOSES IN COMMON DIAGNOSTIC X-RAY EXAMINATIONS.
Metaxas VI; Messaris GA; Lekatou AN; Petsas TG; Panayiotakis GS
Radiat Prot Dosimetry; 2019 Jul; 184(1):12-27. PubMed ID: 30289498
[TBL] [Abstract][Full Text] [Related]
9. Optimisation of patient dose for the horizontal beam technique in lateral lumbar spine radiographic examinations.
Davis AT; Hopkins SA
Br J Radiol; 2013 Jul; 86(1027):20130053. PubMed ID: 23652542
[TBL] [Abstract][Full Text] [Related]
10. Local reference dose evaluation in conventional radiography examinations in Iran.
Shirin Shandiz M; Bahreyni Toosi MT; Farsi S; Yaghobi K
J Appl Clin Med Phys; 2014 Mar; 15(2):4550. PubMed ID: 24710442
[TBL] [Abstract][Full Text] [Related]
11. Effective dose reduction in spine radiographic imaging by choosing the less radiation-sensitive side of the body.
Ben-Shlomo A; Bartal G; Mosseri M; Avraham B; Leitner Y; Shabat S
Spine J; 2016 Apr; 16(4):558-63. PubMed ID: 26704861
[TBL] [Abstract][Full Text] [Related]
12. Reducing the lifetime risk of cancer from spinal radiographs among people with adolescent idiopathic scoliosis.
Levy AR; Goldberg MS; Mayo NE; Hanley JA; Poitras B
Spine (Phila Pa 1976); 1996 Jul; 21(13):1540-7; discussion 1548. PubMed ID: 8817782
[TBL] [Abstract][Full Text] [Related]
13. Monitoring neurointerventional radiation doses using dose-tracking software: implications for the establishment of local diagnostic reference levels.
Acton H; James K; Kavanagh RG; O'Tuathaigh C; Moloney D; Wyse G; Fanning N; Maher M; O'Connor OJ
Eur Radiol; 2018 Sep; 28(9):3669-3675. PubMed ID: 29651772
[TBL] [Abstract][Full Text] [Related]
14. Patient Radiation Dosage During Lower Extremity Endovascular Intervention.
Goldsweig AM; Kennedy KF; Abbott JD; Jones WS; Velagapudi P; Rutar FJ; Curtis JC; Tsai TT; Aronow HD
JACC Cardiovasc Interv; 2019 Mar; 12(5):473-480. PubMed ID: 30846087
[TBL] [Abstract][Full Text] [Related]
15. Development of radiation exposure in patients undergoing pulmonary vein isolation in Germany between 2007 and 2014: great potential to minimize radiation dosage.
Kleemann T; Brachmann J; Lewalter T; Andresen D; Willems S; Spitzer SG; Hoffmann E; Eckardt L; Hochadel M; Senges J; Kuck KH; Seidl K; Zahn R
Clin Res Cardiol; 2016 Oct; 105(10):858-64. PubMed ID: 27142281
[TBL] [Abstract][Full Text] [Related]
16. How does a non-optimal tube potential influence radiation dose to the patient in lumbar spine radiography?
Alukic E; Mekis N
Radiography (Lond); 2021 Nov; 27(4):1105-1109. PubMed ID: 34011453
[TBL] [Abstract][Full Text] [Related]
17. Dose-area product measurements in paediatric radiography.
McDonald S; Martin CJ; Darragh CL; Graham DT
Br J Radiol; 1996 Apr; 69(820):318-25. PubMed ID: 8665131
[TBL] [Abstract][Full Text] [Related]
18. A large-scale multicentre study of patient skin doses in interventional cardiology: dose-area product action levels and dose reference levels.
Bogaert E; Bacher K; Lemmens K; Carlier M; Desmet W; De Wagter X; Djian D; Hanet C; Heyndrickx G; Legrand V; Taeymans Y; Thierens H
Br J Radiol; 2009 Apr; 82(976):303-12. PubMed ID: 19124567
[TBL] [Abstract][Full Text] [Related]
19. Projected Future Cancer Risks in Children Treated With Fluoroscopy-Guided Cardiac Catheterization Procedures.
Journy N; Dreuil S; Rage E; De Zordo-Banliat F; Bonnet D; Hascoët S; Malekzadeh-Milani S; Petit J; Laurier D; Bernier MO; Baysson H
Circ Cardiovasc Interv; 2018 Nov; 11(11):e006765. PubMed ID: 30571202
[TBL] [Abstract][Full Text] [Related]
20. Radiation exposure from diagnostic radiographs in extremely low birth weight infants.
Wilson-Costello D; Rao PS; Morrison S; Hack M
Pediatrics; 1996 Mar; 97(3):369-74. PubMed ID: 8604273
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]