These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
249 related articles for article (PubMed ID: 30572931)
1. Military trainees can accurately measure optic nerve sheath diameter after a brief training session. Betcher J; Becker TK; Stoyanoff P; Cranford J; Theyyunni N Mil Med Res; 2018 Dec; 5(1):42. PubMed ID: 30572931 [TBL] [Abstract][Full Text] [Related]
2. Ocular ultrasound evaluation of optic nerve sheath diameter in military environments. De Bernardo M; Vitiello L; Cornetta P; Rosa N Mil Med Res; 2019 May; 6(1):16. PubMed ID: 31126318 [TBL] [Abstract][Full Text] [Related]
3. Can accurate ultrasonographic measurement of the optic nerve sheath diameter (a non-invasive measure of intracranial pressure) be taught to novice operators in a single training session? Potgieter DW; Kippin A; Ngu F; McKean C Anaesth Intensive Care; 2011 Jan; 39(1):95-100. PubMed ID: 21375098 [TBL] [Abstract][Full Text] [Related]
4. Bedside sonographic measurement of optic nerve sheath diameter as a predictor of increased intracranial pressure in children. Le A; Hoehn ME; Smith ME; Spentzas T; Schlappy D; Pershad J Ann Emerg Med; 2009 Jun; 53(6):785-91. PubMed ID: 19167786 [TBL] [Abstract][Full Text] [Related]
5. A Prospective Study of Optic Nerve Ultrasound for the Detection of Elevated Intracranial Pressure in Severe Traumatic Brain Injury. Agrawal D; Raghavendran K; Zhao L; Rajajee V Crit Care Med; 2020 Dec; 48(12):e1278-e1285. PubMed ID: 33048902 [TBL] [Abstract][Full Text] [Related]
6. Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients. Tayal VS; Neulander M; Norton HJ; Foster T; Saunders T; Blaivas M Ann Emerg Med; 2007 Apr; 49(4):508-14. PubMed ID: 16997419 [TBL] [Abstract][Full Text] [Related]
7. Can ocular ultrasound predict intracranial hypertension? A pilot diagnostic accuracy evaluation in a UK emergency department. Qayyum H; Ramlakhan S Eur J Emerg Med; 2013 Apr; 20(2):91-7. PubMed ID: 22327166 [TBL] [Abstract][Full Text] [Related]
8. Comparison of Two Techniques to Measure Optic Nerve Sheath Diameter in Patients at Risk for Increased Intracranial Pressure. Agrawal A; Cheng R; Tang J; Madhok DY Crit Care Med; 2019 Jun; 47(6):e495-e501. PubMed ID: 30882482 [TBL] [Abstract][Full Text] [Related]
9. Coronal Axis Measurement of the Optic Nerve Sheath Diameter Using a Linear Transducer. Amini R; Stolz LA; Patanwala AE; Adhikari S J Ultrasound Med; 2015 Sep; 34(9):1607-12. PubMed ID: 26254151 [TBL] [Abstract][Full Text] [Related]
10. Inter-rater Reliability of Sonographic Optic Nerve Sheath Diameter Measurements by Emergency Medicine Physicians. Oberfoell S; Murphy D; French A; Trent S; Richards D J Ultrasound Med; 2017 Aug; 36(8):1579-1584. PubMed ID: 28370143 [TBL] [Abstract][Full Text] [Related]
11. Bedside Optic Nerve Ultrasonography for Diagnosing Increased Intracranial Pressure: A Systematic Review and Meta-analysis. Koziarz A; Sne N; Kegel F; Nath S; Badhiwala JH; Nassiri F; Mansouri A; Yang K; Zhou Q; Rice T; Faidi S; Passos E; Healey A; Banfield L; Mensour M; Kirkpatrick AW; Nassar A; Fehlings MG; Hawryluk GWJ; Almenawer SA Ann Intern Med; 2019 Dec; 171(12):896-905. PubMed ID: 31739316 [TBL] [Abstract][Full Text] [Related]
12. Accuracy of optic nerve sheath diameter measurement by emergency physicians using bedside ultrasound. Hassen GW; Bruck I; Donahue J; Mason B; Sweeney B; Saab W; Weedon J; Patel N; Perry K; Matari H; Jaiswal R; Kalantari H J Emerg Med; 2015 Apr; 48(4):450-7. PubMed ID: 25497897 [TBL] [Abstract][Full Text] [Related]
13. Study of the effect of anaesthesia on the canine ultrasonographic optic nerve sheath diameter. Drolet C; Pinard C; Gaitero L; Monteith G; Bateman S J Small Anim Pract; 2021 Dec; 62(12):1070-1078. PubMed ID: 34264530 [TBL] [Abstract][Full Text] [Related]
14. Effects of acute controlled changes in end-tidal carbon dioxide on the diameter of the optic nerve sheath: a transorbital ultrasonographic study in healthy volunteers. Dinsmore M; Han JS; Fisher JA; Chan VW; Venkatraghavan L Anaesthesia; 2017 May; 72(5):618-623. PubMed ID: 28177116 [TBL] [Abstract][Full Text] [Related]
16. Ultrasonographic Optic Nerve Sheath Diameter Measurement to Detect Intracranial Hypertension in Children With Neurological Injury: A Systematic Review. Bhargava V; Tawfik D; Tan YJ; Dunbar T; Haileselassie B; Su E Pediatr Crit Care Med; 2020 Sep; 21(9):e858-e868. PubMed ID: 32796395 [TBL] [Abstract][Full Text] [Related]
17. Effects of prone positioning with neck extension on intracranial pressure according to optic nerve sheath diameter measured using ultrasound in children. Yoon SB; Ji SH; Jang YE; Lee JH; Kim EH; Kim JT; Kim HS Childs Nerv Syst; 2020 May; 36(5):1001-1007. PubMed ID: 31797072 [TBL] [Abstract][Full Text] [Related]
18. Sonography for determining the optic nerve sheath diameter with increasing intracranial pressure in a porcine model. Hamilton DR; Sargsyan AE; Melton SL; Garcia KM; Oddo B; Kwon DS; Feiveson AH; Dulchavsky SA J Ultrasound Med; 2011 May; 30(5):651-9. PubMed ID: 21527613 [TBL] [Abstract][Full Text] [Related]
19. Dilated Optic Nerve Sheath in Mucopolysaccharidosis I: Common and Not Necessarily High Intracranial Pressure. Huang S; Lund T; Orchard P; Gupta A; Nascene D AJNR Am J Neuroradiol; 2023 Jan; 44(1):91-94. PubMed ID: 36581456 [TBL] [Abstract][Full Text] [Related]
20. The Measurement of Elderly Volunteers' Optic Nerve Sheath Diameters by Ocular Ultrasonography. Avci M; Kozaci N; Komut E; Komut S; Caliskan G; Tulubas G Medicina (Kaunas); 2019 Jul; 55(8):. PubMed ID: 31357667 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]