These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 30581849)

  • 1. Recommended Drilling Parameters of Tungsten Carbide Round Drills for the Most Optimal Bone Removals in Oral Surgery.
    Szalma J; Klein O; Lovász BV; Lempel E; Jeges S; Olasz L
    Biomed Res Int; 2018; 2018():3108581. PubMed ID: 30581849
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intraosseous Heat Production and Preparation Efficiency of Surgical Tungsten Carbide Round Drills: The Effect of Coronectomy on Drill Wear.
    Szalma J; Kiss C; Gurdán Z; Tóth Á; Olasz L; Jakse N
    J Oral Maxillofac Surg; 2016 Mar; 74(3):442-52. PubMed ID: 26704431
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Slow drilling speeds for single-drill implant bed preparation. Experimental in vitro study.
    Delgado-Ruiz RA; Velasco Ortega E; Romanos GE; Gerhke S; Newen I; Calvo-Guirado JL
    Clin Oral Investig; 2018 Jan; 22(1):349-359. PubMed ID: 28434045
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Descriptive study of the longevity of dental implant surgery drills.
    Allsobrook OF; Leichter J; Holborrow D; Swain M
    Clin Implant Dent Relat Res; 2011 Sep; 13(3):244-54. PubMed ID: 22106473
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Tooth sectioning for coronectomy: how to perform?
    Szalma J; Vajta L; Olasz L; Lempel E
    Clin Oral Investig; 2019 Feb; 23(2):519-527. PubMed ID: 29691663
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Heat production by 3 implant drill systems after repeated drilling and sterilization.
    Chacon GE; Bower DL; Larsen PE; McGlumphy EA; Beck FM
    J Oral Maxillofac Surg; 2006 Feb; 64(2):265-9. PubMed ID: 16413899
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Heat generation during implant site preparation: an in vitro study.
    Cordioli G; Majzoub Z
    Int J Oral Maxillofac Implants; 1997; 12(2):186-93. PubMed ID: 9109268
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An experimental comparative study of drilling efficiency and temperature elevation with unmodified and modified medical drills in pig tibia bone.
    Enokida M; Kanaya H; Uehara K; Ueki M; Nagashima H
    Heliyon; 2019 Aug; 5(8):e02189. PubMed ID: 31417971
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Heat Generation During Guided and Freehand Implant Site Preparation at Drilling Speeds of 1500 and 2000 RPM at Different Irrigation Temperatures: An In Vitro Study.
    Barrak I; Boa K; Joób-Fancsaly Á; Varga E; Sculean A; Piffkó J
    Oral Health Prev Dent; 2019; 17(4):309-316. PubMed ID: 31093616
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of pre-drilling on intraosseous temperature during self-drilling mini-implant placement in a porcine mandible model.
    Gurdán Z; Vajta L; Tóth Á; Lempel E; Joób-Fancsaly Á; Szalma J
    J Oral Sci; 2017 Mar; 59(1):47-53. PubMed ID: 28049965
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Infrared thermographic evaluation of temperature modifications induced during implant site preparation with cylindrical versus conical drills.
    Scarano A; Piattelli A; Assenza B; Carinci F; Di Donato L; Romani GL; Merla A
    Clin Implant Dent Relat Res; 2011 Dec; 13(4):319-23. PubMed ID: 19681941
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites.
    Brisman DL
    Int J Oral Maxillofac Implants; 1996; 11(1):35-7. PubMed ID: 8820120
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Thermal effects of various drill materials during implant site preparation-Ceramic vs. stainless steel drills: A comparative in vitro study in a standardised bovine bone model.
    Tur D; Giannis K; Unger E; Mittlböck M; Rausch-Fan X; Strbac GD
    Clin Oral Implants Res; 2021 Feb; 32(2):154-166. PubMed ID: 33220104
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Experimental Analysis of Temperature Differences During Implant Site Preparation: Continuous Drilling Technique Versus Intermittent Drilling Technique.
    Di Fiore A; Sivolella S; Stocco E; Favero V; Stellini E
    J Oral Implantol; 2018 Feb; 44(1):46-50. PubMed ID: 29135381
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability.
    Ercoli C; Funkenbusch PD; Lee HJ; Moss ME; Graser GN
    Int J Oral Maxillofac Implants; 2004; 19(3):335-49. PubMed ID: 15214217
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel, new generation drill coating for osteotomy site preparation.
    Wadkar PP; Khalap S; Shetty D; Gupta A; Shetty A; Dharmadhikari S
    Indian J Dent Res; 2019; 30(5):767-771. PubMed ID: 31854371
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Multistepped Drill Design for Single-Stage Implant Site Preparation: Experimental Study in Type 2 Bone.
    Abboud M; Delgado-Ruiz RA; Kucine A; Rugova S; Balanta J; Calvo-Guirado JL
    Clin Implant Dent Relat Res; 2015 Oct; 17 Suppl 2():e472-85. PubMed ID: 25263993
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Temperature changes during cortical bone drilling with a newly designed step drill and an internally cooled drill.
    Augustin G; Davila S; Udilljak T; Staroveski T; Brezak D; Babic S
    Int Orthop; 2012 Jul; 36(7):1449-56. PubMed ID: 22290154
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The influence of the chosen in vitro bone simulation model on intraosseous temperatures and drilling times.
    Szalma J; Lovász BV; Vajta L; Soós B; Lempel E; Möhlhenrich SC
    Sci Rep; 2019 Aug; 9(1):11817. PubMed ID: 31413292
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of the implant drill design and sequence on temperature changes during site preparation.
    Sannino G; Capparé P; Gherlone EF; Barlattani A
    Int J Oral Maxillofac Implants; 2015; 30(2):351-8. PubMed ID: 25153005
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.