These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 30582552)

  • 1. A Fully Integrated Current-Mode Continuous-Time Delta-Sigma Modulator for Biological Nanopore Read Out.
    Amayreh M; Baaken G; Behrends JC; Manoli Y
    IEEE Trans Biomed Circuits Syst; 2019 Feb; 13(1):225-236. PubMed ID: 30582552
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Direct Current-Sensing VCO-Based 2nd-Order Continuous-Time Sigma-Delta Modulator for Biosensor Readout Applications.
    Lee SY; Hsieh YT; Lee HY; Chang SS; Chen JY
    IEEE Trans Biomed Circuits Syst; 2024 Apr; 18(2):288-298. PubMed ID: 37812555
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reconfigurable Sensor Analog Front-End Using Low-Noise Chopper-Stabilized Delta-Sigma Capacitance-to-Digital Converter.
    Kim H; Lee B; Mun Y; Kim J; Han K; Roh Y; Song D; Huh S; Ko H
    Micromachines (Basel); 2018 Jul; 9(7):. PubMed ID: 30424280
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A 1V low power second-order delta-sigma modulator for biomedical signal application.
    Hsu CH; Tang KT
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():2008-11. PubMed ID: 24110111
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A 1.2-V 165-μW 0.29-mm2 multibit Sigma-Delta ADC for hearing aids using nonlinear DACs and with over 91 dB dynamic-range.
    Custodio JR; Goes J; Paulino N; Oliveira JP; Bruun E
    IEEE Trans Biomed Circuits Syst; 2013 Jun; 7(3):376-85. PubMed ID: 23853337
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A 2.64- μW 71-dB SNDR Discrete-Time Signal-Folding Amplifier for Reducing ADC's Resolution Requirement in Wearable ECG Acquisition Systems.
    Ratametha C; Tepwimonpetkun S; Wattanapanitch W
    IEEE Trans Biomed Circuits Syst; 2020 Feb; 14(1):48-64. PubMed ID: 31796416
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A low power multichannel analog front end for portable neural signal recordings.
    Obeid I; Nicolelis MA; Wolf PD
    J Neurosci Methods; 2004 Feb; 133(1-2):27-32. PubMed ID: 14757341
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Study of a High-Precision Read-Out Integrated Circuit for Bridge Sensors.
    Li X; Wang P; Ye H; He H; Zhang X
    Micromachines (Basel); 2023 Oct; 14(11):. PubMed ID: 38004870
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A 0.8-μW and 74-dB High-Pass Sigma-Delta Modulator With OPAMP Sharing and Noise-Coupling Techniques for Biomedical Signal Acquisition.
    Lee SY; Lee HY; Kung CH; Su PH; Chen JY
    IEEE Trans Biomed Circuits Syst; 2022 Oct; 16(5):742-751. PubMed ID: 36001522
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design and measurements of low power multichannel chip for recording and stimulation of neural activity.
    Zoladz M; Kmon P; Grybos P; Szczygiel R; Kleczek R; Otfinowski P; Rauza J
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():4470-4. PubMed ID: 23366920
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Power Adaptive, 1.22-pW/Hz, 10-MHz Read-Out Front-End for Bio-Impedance Measurement.
    Takhti M; Odame K
    IEEE Trans Biomed Circuits Syst; 2019 Aug; 13(4):725-734. PubMed ID: 31135369
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A third-order complementary metal-oxide-semiconductor sigma-delta modulator operating between 4.2 K and 300 K.
    Okcan B; Gielen G; Van Hoof C
    Rev Sci Instrum; 2012 Feb; 83(2):024708. PubMed ID: 22380114
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Low-Voltage OTA-C Filter With an Area- and Power-Efficient OTA for Biosignal Sensor Applications.
    Lee SY; Wang CP; Chu YS
    IEEE Trans Biomed Circuits Syst; 2019 Feb; 13(1):56-67. PubMed ID: 30475730
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A High-Dynamic-Range Switched-Capacitor Sigma-Delta ADC for Digital Micromechanical Vibration Gyroscopes.
    Lv R; Chen W; Liu X
    Micromachines (Basel); 2018 Jul; 9(8):. PubMed ID: 30424305
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Low Power Sigma-Delta Modulator with Hybrid Architecture.
    An S; Xia S; Ma Y; Ghani A; See CH; Abd-Alhameed RA; Niu C; Yang R
    Sensors (Basel); 2020 Sep; 20(18):. PubMed ID: 32948053
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A low-power configurable neural recording system for epileptic seizure detection.
    Qian C; Shi J; Parramon J; Sánchez-Sinencio E
    IEEE Trans Biomed Circuits Syst; 2013 Aug; 7(4):499-512. PubMed ID: 23893209
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Robust 96.6-dB-SNDR 50-kHz-Bandwidth Switched-Capacitor Delta-Sigma Modulator for IR Imagers in Space Instrumentation.
    Dei M; Sutula S; Cisneros J; Pun E; Jansen RJE; Terés L; Serra-Graells F
    Sensors (Basel); 2017 Jun; 17(6):. PubMed ID: 28574466
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Fully Integrated Bluetooth Low-Energy Transceiver with Integrated Single Pole Double Throw and Power Management Unit for IoT Sensors.
    Kim SJ; Kim DG; Oh SJ; Lee DS; Pu YG; Hwang KC; Yang Y; Lee KY
    Sensors (Basel); 2019 May; 19(10):. PubMed ID: 31137903
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A 1 MHz BW 34.2 fJ/step Continuous Time Delta Sigma Modulator With an Integrated Mixer for Cardiac Ultrasound.
    Kaald R; Eggen T; Ytterdal T
    IEEE Trans Biomed Circuits Syst; 2017 Feb; 11(1):234-243. PubMed ID: 27608480
    [TBL] [Abstract][Full Text] [Related]  

  • 20. CMOS low current measurement system for biomedical applications.
    Goldstein B; Kim D; Xu J; Vanderlick TK; Culurciello E
    IEEE Trans Biomed Circuits Syst; 2012 Apr; 6(2):111-9. PubMed ID: 23852976
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.