264 related articles for article (PubMed ID: 30583520)
1. Construction of a Biosensor Based on a Combination of Cytochrome
Guo C; Wang J; Chen X; Li Y; Wu L; Zhang J; Tao CA
Sensors (Basel); 2018 Dec; 19(1):. PubMed ID: 30583520
[TBL] [Abstract][Full Text] [Related]
2. Investigate electrochemical immunosensor of cortisol based on gold nanoparticles/magnetic functionalized reduced graphene oxide.
Sun B; Gou Y; Ma Y; Zheng X; Bai R; Ahmed Abdelmoaty AA; Hu F
Biosens Bioelectron; 2017 Feb; 88():55-62. PubMed ID: 27499382
[TBL] [Abstract][Full Text] [Related]
3. Hydrogen peroxide biosensor based on hemoglobin immobilized at graphene, flower-like zinc oxide, and gold nanoparticles nanocomposite modified glassy carbon electrode.
Xie L; Xu Y; Cao X
Colloids Surf B Biointerfaces; 2013 Jul; 107():245-50. PubMed ID: 23502047
[TBL] [Abstract][Full Text] [Related]
4. Very sensitive electrochemical determination of diuron on glassy carbon electrode modified with reduced graphene oxide-gold nanoparticle-Nafion composite film.
Zarei K; Khodadadi A
Ecotoxicol Environ Saf; 2017 Oct; 144():171-177. PubMed ID: 28622555
[TBL] [Abstract][Full Text] [Related]
5. Amperometric determination of L-cysteine using a glassy carbon electrode modified with palladium nanoparticles grown on reduced graphene oxide in a Nafion matrix.
Yusoff N; Rameshkumar P; Mohamed Noor A; Huang NM
Mikrochim Acta; 2018 Apr; 185(4):246. PubMed ID: 29616348
[TBL] [Abstract][Full Text] [Related]
6. Electrochemical detection of Salmonella using an invA genosensor on polypyrrole-reduced graphene oxide modified glassy carbon electrode and AuNPs-horseradish peroxidase-streptavidin as nanotag.
Ye Y; Yan W; Liu Y; He S; Cao X; Xu X; Zheng H; Gunasekaran S
Anal Chim Acta; 2019 Oct; 1074():80-88. PubMed ID: 31159942
[TBL] [Abstract][Full Text] [Related]
7. Enhanced electrocatalytic activity of graphene-gold nanoparticles hybrids for peroxynitrite electrochemical detection on hemin-based electrode.
Wang B; Ji X; Ren J; Ni R; Wang L
Bioelectrochemistry; 2017 Dec; 118():75-82. PubMed ID: 28746901
[TBL] [Abstract][Full Text] [Related]
8. A novel enzyme-free amperometric sensor for hydrogen peroxide based on Nafion/exfoliated graphene oxide-Co3O4 nanocomposite.
Ensafi AA; Jafari-Asl M; Rezaei B
Talanta; 2013 Jan; 103():322-9. PubMed ID: 23200394
[TBL] [Abstract][Full Text] [Related]
9. Ternary nanohybrid of reduced graphene oxide-nafion@silver nanoparticles for boosting the sensor performance in non-enzymatic amperometric detection of hydrogen peroxide.
Yusoff N; Rameshkumar P; Mehmood MS; Pandikumar A; Lee HW; Huang NM
Biosens Bioelectron; 2017 Jan; 87():1020-1028. PubMed ID: 27697744
[TBL] [Abstract][Full Text] [Related]
10. Reduced graphene oxide/nile blue/gold nanoparticles complex-modified glassy carbon electrode used as a sensitive and label-free aptasensor for ratiometric electrochemical sensing of dopamine.
Jin H; Zhao C; Gui R; Gao X; Wang Z
Anal Chim Acta; 2018 Sep; 1025():154-162. PubMed ID: 29801604
[TBL] [Abstract][Full Text] [Related]
11. Preparation and characterization of AuNPs/CNTs-ErGO electrochemical sensors for highly sensitive detection of hydrazine.
Zhao Z; Sun Y; Li P; Zhang W; Lian K; Hu J; Chen Y
Talanta; 2016 Sep; 158():283-291. PubMed ID: 27343607
[TBL] [Abstract][Full Text] [Related]
12. A sensitive DNA biosensor fabricated from gold nanoparticles and graphene oxide on a glassy carbon electrode.
Hajihosseini S; Nasirizadeh N; Hejazi MS; Yaghmaei P
Mater Sci Eng C Mater Biol Appl; 2016 Apr; 61():506-15. PubMed ID: 26838878
[TBL] [Abstract][Full Text] [Related]
13. A novel electrochemical sensor for the analysis of β-agonists: the poly(acid chrome blue K)/graphene oxide-nafion/glassy carbon electrode.
Lin X; Ni Y; Kokot S
J Hazard Mater; 2013 Sep; 260():508-17. PubMed ID: 23811373
[TBL] [Abstract][Full Text] [Related]
14. Ultrasensitive DNA sensor based on gold nanoparticles/reduced graphene oxide/glassy carbon electrode.
Benvidi A; Firouzabadi AD; Moshtaghiun SM; Mazloum-Ardakani M; Tezerjani MD
Anal Biochem; 2015 Sep; 484():24-30. PubMed ID: 25988596
[TBL] [Abstract][Full Text] [Related]
15. Square-wave stripping voltammetric determination of caffeic acid on electrochemically reduced graphene oxide-Nafion composite film.
Filik H; Çetintaş G; Avan AA; Aydar S; Koç SN; Boz İ
Talanta; 2013 Nov; 116():245-50. PubMed ID: 24148400
[TBL] [Abstract][Full Text] [Related]
16. A novel electrochemical biosensor based on the hemin-graphene nano-sheets and gold nano-particles hybrid film for the analysis of hydrogen peroxide.
Song H; Ni Y; Kokot S
Anal Chim Acta; 2013 Jul; 788():24-31. PubMed ID: 23845477
[TBL] [Abstract][Full Text] [Related]
17. Synthesis of one-dimensional gold nanostructures and the electrochemical application of the nanohybrid containing functionalized graphene oxide for cholesterol biosensing.
Nandini S; Nalini S; Reddy MB; Suresh GS; Melo JS; Niranjana P; Sanetuntikul J; Shanmugam S
Bioelectrochemistry; 2016 Aug; 110():79-90. PubMed ID: 27100467
[TBL] [Abstract][Full Text] [Related]
18. An acetylcholinesterase biosensor based on platinum nanoparticles-carboxylic graphene-nafion-modified electrode for detection of pesticides.
Yang L; Wang G; Liu Y
Anal Biochem; 2013 Jun; 437(2):144-9. PubMed ID: 23499967
[TBL] [Abstract][Full Text] [Related]
19. Highly Sensitive Electrochemical Biosensor for Evaluation of Oxidative Stress Based on the Nanointerface of Graphene Nanocomposites Blended with Gold, Fe3O4, and Platinum Nanoparticles.
Wang L; Zhang Y; Cheng C; Liu X; Jiang H; Wang X
ACS Appl Mater Interfaces; 2015 Aug; 7(33):18441-9. PubMed ID: 26238430
[TBL] [Abstract][Full Text] [Related]
20. Real-time electrochemical detection of hydrogen peroxide secretion in live cells by Pt nanoparticles decorated graphene-carbon nanotube hybrid paper electrode.
Sun Y; He K; Zhang Z; Zhou A; Duan H
Biosens Bioelectron; 2015 Jun; 68():358-364. PubMed ID: 25603401
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]