These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
374 related articles for article (PubMed ID: 30583690)
1. Diagnostic Accuracy of Axillary Ultrasonography Compared with Intra-operative Pathological Findings in Patients with Breast Cancer. Rezvani A; Zahergivar A; Iranpour P; Akrami M; Kazemi S Asian Pac J Cancer Prev; 2018 Dec; 19(12):3615-3621. PubMed ID: 30583690 [TBL] [Abstract][Full Text] [Related]
2. The clinical utility of combining pre-operative axillary ultrasonography and fine needle aspiration cytology with radionuclide guided sentinel lymph node biopsy in breast cancer patients with palpable axillary lymph nodes. Usmani S; Ahmed N; Al Saleh N; abu Huda F; Amanguno HG; Amir T; al Kandari F Eur J Radiol; 2015 Dec; 84(12):2515-20. PubMed ID: 26474908 [TBL] [Abstract][Full Text] [Related]
3. Pre-operative and intra-operative detection of axillary lymph node metastases in 108 patients with invasive lobular breast cancer undergoing mastectomy. Novak J; Besic N; Dzodic R; Gazic B; Vogrin A BMC Cancer; 2018 Feb; 18(1):137. PubMed ID: 29402252 [TBL] [Abstract][Full Text] [Related]
4. The sensitivity of pre-operative axillary staging in breast cancer: comparison of invasive lobular and ductal carcinoma. Topps A; Clay V; Absar M; Howe M; Lim Y; Johnson R; Bundred N Eur J Surg Oncol; 2014 Jul; 40(7):813-7. PubMed ID: 24797703 [TBL] [Abstract][Full Text] [Related]
5. The Relevance of Ultrasound Imaging of Suspicious Axillary Lymph Nodes and Fine-needle Aspiration Biopsy in the Post-ACOSOG Z11 Era in Early Breast Cancer. Vijayaraghavan GR; Vedantham S; Kataoka M; DeBenedectis C; Quinlan RM Acad Radiol; 2017 Mar; 24(3):308-315. PubMed ID: 27916595 [TBL] [Abstract][Full Text] [Related]
6. Axillary tumour burden in women with a fine-needle aspiration/core biopsy-proven positive node on ultrasonography compared to women with a positive sentinel node. Lloyd P; Theophilidou E; Newcombe RG; Pugh L; Goyal A Br J Surg; 2017 Dec; 104(13):1811-1815. PubMed ID: 28991362 [TBL] [Abstract][Full Text] [Related]
7. The impact of preoperative axillary ultrasonography in T1 breast tumours. del Riego J; Diaz-Ruiz MJ; Teixidó M; Ribé J; Vilagran M; Canales L; Sentís M; Eur Radiol; 2016 Apr; 26(4):1073-81. PubMed ID: 26162580 [TBL] [Abstract][Full Text] [Related]
8. Negative axillary ultrasonography with biopsy may predict non-involvement of the non-sentinel lymph nodes in operable breast cancer patients. Al Ayyan M; Bu Ali O; Al Sharri S; Kassis A; Hussain S; Al-Bashir M Asia Pac J Clin Oncol; 2014 Jun; 10(2):e86-9. PubMed ID: 23167952 [TBL] [Abstract][Full Text] [Related]
9. Initial axillary staging of breast cancer using ultrasound-guided fine needle aspiration: a liquid-based cytology study. Schiettecatte A; Bourgain C; Breucq C; Buls N; De Wilde V; de Mey J Cytopathology; 2011 Feb; 22(1):30-5. PubMed ID: 20337693 [TBL] [Abstract][Full Text] [Related]
10. Pre-operative axillary ultrasound with fine-needle aspiration cytology performance and predictive factors of false negatives in axillary lymph node involvement in early breast cancer. Hotton J; Salleron J; Henrot P; Buhler J; Leufflen L; Rauch P; Marchal F Breast Cancer Res Treat; 2020 Oct; 183(3):639-647. PubMed ID: 32737710 [TBL] [Abstract][Full Text] [Related]
11. Axillary ultrasound and Fine-Needle Aspiration Cytology in the preoperative staging of axillary node metastasis in breast cancer patients. Gipponi M; Fregatti P; Garlaschi A; Murelli F; Margarino C; Depaoli F; Baccini P; Gallo M; Friedman D Breast; 2016 Dec; 30():146-150. PubMed ID: 27728855 [TBL] [Abstract][Full Text] [Related]
12. Clinical utility of routine pre-operative axillary ultrasound and fine needle aspiration cytology in patient selection for sentinel lymph node biopsy. Rattay T; Muttalib M; Khalifa E; Duncan A; Parker SJ Breast; 2012 Apr; 21(2):210-4. PubMed ID: 21981897 [TBL] [Abstract][Full Text] [Related]
13. Axillary lymph nodes suspicious for breast cancer metastasis: sampling with US-guided 14-gauge core-needle biopsy--clinical experience in 100 patients. Abe H; Schmidt RA; Kulkarni K; Sennett CA; Mueller JS; Newstead GM Radiology; 2009 Jan; 250(1):41-9. PubMed ID: 18955508 [TBL] [Abstract][Full Text] [Related]
14. [Axillary lymph node aspiration guided by ultrasound is effective as a method of predicting lymph node involvement in patients with breast cancer?]. Pessoa EC; Rodrigues JR; Pessoa CP; Véspoli HM; Uemura G Rev Bras Ginecol Obstet; 2014 Mar; 36(3):118-23. PubMed ID: 24728315 [TBL] [Abstract][Full Text] [Related]
15. Axillary lymph node echo-guided fine-needle aspiration cytology enables breast cancer patients to avoid a sentinel lymph node biopsy. Preliminary experience and a review of the literature. Altomare V; Guerriero G; Carino R; Battista C; Primavera A; Altomare A; Vaccaro D; Esposito A; Ferri AM; Rabitti C Surg Today; 2007; 37(9):735-9. PubMed ID: 17713725 [TBL] [Abstract][Full Text] [Related]
16. The validity and clinical utility of axillary ultrasonography-guided fine needle aspiration biopsy in detection of nodal metastasis in early-stage breast cancer patients: a retrospective single-center experience. Taşçı F; Metin Y; Metin NO; Kadıoğlu ME; Gözükara MG; Kul S Turk J Med Sci; 2022 Aug; 52(4):1160-1168. PubMed ID: 36326392 [TBL] [Abstract][Full Text] [Related]
17. The impact of axillary ultrasound with biopsy in overtreatment of early breast cancer. Del Riego J; Diaz-Ruiz MJ; Teixidó M; Ribé J; Vilagran M; Canales L; Sentís M; Eur J Radiol; 2018 Jan; 98():158-164. PubMed ID: 29279156 [TBL] [Abstract][Full Text] [Related]
18. Pretreatment axillary ultrasonography and core biopsy in patients with suspected breast cancer: diagnostic accuracy and impact on management. Garcia-Ortega MJ; Benito MA; Vahamonde EF; Torres PR; Velasco AB; Paredes MM Eur J Radiol; 2011 Jul; 79(1):64-72. PubMed ID: 20047809 [TBL] [Abstract][Full Text] [Related]
19. Axillary staging using ultrasound-guided fine needle aspiration biopsy in locally advanced breast cancer. Oruwari JU; Chung MA; Koelliker S; Steinhoff MM; Cady B Am J Surg; 2002 Oct; 184(4):307-9. PubMed ID: 12383889 [TBL] [Abstract][Full Text] [Related]
20. Axillary ultrasound and fine-needle aspiration in the preoperative evaluation of the breast cancer patient: an algorithm based on tumor size and lymph node appearance. Mainiero MB; Cinelli CM; Koelliker SL; Graves TA; Chung MA AJR Am J Roentgenol; 2010 Nov; 195(5):1261-7. PubMed ID: 20966338 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]