347 related articles for article (PubMed ID: 30589162)
1. Measurement of knee joint range of motion with a digital goniometer: A reliability study.
Svensson M; Lind V; Löfgren Harringe M
Physiother Res Int; 2019 Apr; 24(2):e1765. PubMed ID: 30589162
[TBL] [Abstract][Full Text] [Related]
2. Reliability, Concurrent Validity, and Minimal Detectable Change for iPhone Goniometer App in Assessing Knee Range of Motion.
Mehta SP; Barker K; Bowman B; Galloway H; Oliashirazi N; Oliashirazi A
J Knee Surg; 2017 Jul; 30(6):577-584. PubMed ID: 27894147
[TBL] [Abstract][Full Text] [Related]
3. Smartphone goniometer has excellent reliability between novice and experienced physical therapists in assessing knee range of motion.
Mehta SP; Bremer H; Cyrus H; Milligan A; Oliashirazi A
J Bodyw Mov Ther; 2021 Jan; 25():67-74. PubMed ID: 33714514
[TBL] [Abstract][Full Text] [Related]
4. Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study.
Koblbauer IF; Lambrecht Y; van der Hulst ML; Neeter C; Engelbert RH; Poolman RW; Scholtes VA
BMC Musculoskelet Disord; 2011 Oct; 12():249. PubMed ID: 22040119
[TBL] [Abstract][Full Text] [Related]
5. Reproducibility of goniometric measurement of the knee in the in-hospital phase following total knee arthroplasty.
Lenssen AF; van Dam EM; Crijns YH; Verhey M; Geesink RJ; van den Brandt PA; de Bie RA
BMC Musculoskelet Disord; 2007 Aug; 8():83. PubMed ID: 17705860
[TBL] [Abstract][Full Text] [Related]
6. Virtual assessments of knee and wrist joint range motion have comparable reliability with face-to-face assessments.
Mehta SP; Kendall KM; Reasor CM
Musculoskeletal Care; 2021 Jun; 19(2):208-216. PubMed ID: 33107154
[TBL] [Abstract][Full Text] [Related]
7. Reliability of shoulder range of motion comparing a goniometer to a digital level.
Mullaney MJ; McHugh MP; Johnson CP; Tyler TF
Physiother Theory Pract; 2010 Jul; 26(5):327-33. PubMed ID: 20557263
[TBL] [Abstract][Full Text] [Related]
8. Reliability and concurrent validity of knee angle measurement: smart phone app versus universal goniometer used by experienced and novice clinicians.
Milanese S; Gordon S; Buettner P; Flavell C; Ruston S; Coe D; O'Sullivan W; McCormack S
Man Ther; 2014 Dec; 19(6):569-74. PubMed ID: 24942491
[TBL] [Abstract][Full Text] [Related]
9. The Reliability of a Smartphone Goniometer Application Compared With a Traditional Goniometer for Measuring Ankle Joint Range of Motion.
Alawna MA; Unver BH; Yuksel EO
J Am Podiatr Med Assoc; 2019 Jan; 109(1):22-29. PubMed ID: 30964318
[TBL] [Abstract][Full Text] [Related]
10. Reliability of Intraoperative Knee Range of Motion Measurements by Goniometer Compared with Robot-Assisted Arthroplasty.
Kwon HM; Yang IH; Lee WS; Yu ARL; Oh SY; Park KK
J Knee Surg; 2019 Mar; 32(3):233-238. PubMed ID: 29618145
[TBL] [Abstract][Full Text] [Related]
11. Reliability of the EasyAngle® for Assessing Hip Range of Motion in Healthy Children.
Duffy E; Wells M; Miller A; Tondra M; Doty A
Int J Sports Phys Ther; 2024; 19(1):1484-1493. PubMed ID: 38179581
[TBL] [Abstract][Full Text] [Related]
12. Reliability of the Knee Smartphone-Application Goniometer in the Acute Orthopedic Setting.
Pereira LC; Rwakabayiza S; Lécureux E; Jolles BM
J Knee Surg; 2017 Mar; 30(3):223-230. PubMed ID: 27218479
[TBL] [Abstract][Full Text] [Related]
13. Interrater reliability in finger joint goniometer measurement in Dupuytren's disease.
Engstrand C; Krevers B; Kvist J
Am J Occup Ther; 2012; 66(1):98-103. PubMed ID: 22389944
[TBL] [Abstract][Full Text] [Related]
14. Minimal detectable difference of the finger and wrist range of motion: comparison of goniometry and 3D motion analysis.
Reissner L; Fischer G; List R; Taylor WR; Giovanoli P; Calcagni M
J Orthop Surg Res; 2019 Jun; 14(1):173. PubMed ID: 31182129
[TBL] [Abstract][Full Text] [Related]
15. Intrarater reliability of goniometry and hand-held dynamometry for shoulder and elbow examinations in female team handball athletes and asymptomatic volunteers.
Fieseler G; Molitor T; Irlenbusch L; Delank KS; Laudner KG; Hermassi S; Schwesig R
Arch Orthop Trauma Surg; 2015 Dec; 135(12):1719-26. PubMed ID: 26386839
[TBL] [Abstract][Full Text] [Related]
16. A randomized clinical trial of treatment for lumbar segmental rigidity.
Mayer TG; Gatchel RJ; Keeley J; McGeary D; Dersh J; Anagnostis C
Spine (Phila Pa 1976); 2004 Oct; 29(20):2199-205; discussion 2206. PubMed ID: 15480128
[TBL] [Abstract][Full Text] [Related]
17. Knee Osteoarthritis Patients Can Provide Useful Estimates of Passive Knee Range of Motion: Development and Validation of the Copenhagen Knee ROM Scale.
Mørup-Petersen A; Holm PM; Holm CE; Klausen TW; Skou ST; Krogsgaard MR; Laursen MB; Odgaard A
J Arthroplasty; 2018 Sep; 33(9):2875-2883.e3. PubMed ID: 29887360
[TBL] [Abstract][Full Text] [Related]
18. Smartphone technology: a reliable and valid measure of knee movement in knee replacement.
Castle H; Kozak K; Sidhu A; Khan RJK; Haebich S; Bowden V; Fick DP; Goonatillake H
Int J Rehabil Res; 2018 Jun; 41(2):152-158. PubMed ID: 29465474
[TBL] [Abstract][Full Text] [Related]
19. Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects.
Brosseau L; Tousignant M; Budd J; Chartier N; Duciaume L; Plamondon S; O'Sullivan JP; O'Donoghue S; Balmer S
Physiother Res Int; 1997; 2(3):150-66. PubMed ID: 9421820
[TBL] [Abstract][Full Text] [Related]
20. The reliability and concurrent validity of scapular plane shoulder elevation measurements using a digital inclinometer and goniometer.
Kolber MJ; Fuller C; Marshall J; Wright A; Hanney WJ
Physiother Theory Pract; 2012 Feb; 28(2):161-8. PubMed ID: 21721999
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]