BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

340 related articles for article (PubMed ID: 30589941)

  • 1. Part I: Out-of-field dose mapping for 6X and 6X-flattening-filter-free beams on the TrueBeam for extended distances.
    Wijesooriya K
    Med Phys; 2019 Feb; 46(2):868-876. PubMed ID: 30589941
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Part II: Verification of the TrueBeam head shielding model in Varian VirtuaLinac via out-of-field doses.
    Wijesooriya K; Liyanage NK; Kaluarachchi M; Sawkey D
    Med Phys; 2019 Feb; 46(2):877-884. PubMed ID: 30368838
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Surface dose investigation of the flattening filter-free photon beams.
    Wang Y; Khan MK; Ting JY; Easterling SB
    Int J Radiat Oncol Biol Phys; 2012 Jun; 83(2):e281-5. PubMed ID: 22414287
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Measurement of peak correction factor of Farmer chamber for calibration of flattening filter free (FFF) clinical photon beams].
    Kontra G; Major T; Polgár C
    Magy Onkol; 2015 Jun; 59(2):119-23. PubMed ID: 26035159
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Flattening filter free beams in SBRT and IMRT: dosimetric assessment of peripheral doses.
    Kragl G; Baier F; Lutz S; Albrich D; Dalaryd M; Kroupa B; Wiezorek T; Knöös T; Georg D
    Z Med Phys; 2011 May; 21(2):91-101. PubMed ID: 20888199
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ion recombination corrections of ionization chambers in flattening filter-free photon radiation.
    Wang Y; Easterling SB; Ting JY
    J Appl Clin Med Phys; 2012 Sep; 13(5):3758. PubMed ID: 22955642
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A geometrical model for the Monte Carlo simulation of the TrueBeam linac.
    Rodriguez M; Sempau J; Fogliata A; Cozzi L; Sauerwein W; Brualla L
    Phys Med Biol; 2015 Jun; 60(11):N219-29. PubMed ID: 25984796
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.
    Almberg SS; Frengen J; Lindmo T
    Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Improvements in dose accuracy delivered with static-MLC IMRT on an integrated linear accelerator control system.
    Li J; Wiersma RD; Stepaniak CJ; Farrey KJ; Al-Hallaq HA
    Med Phys; 2012 May; 39(5):2456-62. PubMed ID: 22559616
    [TBL] [Abstract][Full Text] [Related]  

  • 10. MO-A-BRB-02: Facts and Fiction of Flattening Filter Free (FF-FFF) X-Rays Beams.
    Ting J
    Med Phys; 2012 Jun; 39(6Part20):3861-3862. PubMed ID: 28517518
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Beam characteristics of energy-matched flattening filter free beams.
    Paynter D; Weston SJ; Cosgrove VP; Evans JA; Thwaites DI
    Med Phys; 2014 May; 41(5):052103. PubMed ID: 24784392
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comprehensive Study of the Out of Field Non Target Dose Associated with 6 and 10 MV Flattened and Flattening Filter Free X Ray Beam in a True Beam Linear Accelerator.
    Athiyaman H; Anbu G; Mayilvaganan A; Chougule A; Sharma N; Kumar HS
    Asian Pac J Cancer Prev; 2024 May; 25(5):1529-1538. PubMed ID: 38809624
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A modification of flattening filter free linac for IMRT.
    Tsiamas P; Seco J; Han Z; Bhagwat M; Maddox J; Kappas C; Theodorou K; Makrigiorgos M; Marcus K; Zygmanski P
    Med Phys; 2011 May; 38(5):2342-52. PubMed ID: 21776768
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Field correction factors for a PTW-31016 Pinpoint ionization chamber for both flattened and unflattened beams. Study of the main sources of uncertainties.
    Puxeu-Vaqué J; Duch MA; Nailon WH; Cruz Lizuain M; Ginjaume M
    Med Phys; 2017 May; 44(5):1930-1938. PubMed ID: 28261817
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinically relevant investigation of flattening filter-free skin dose.
    Guy CL; Karki K; Sharma M; Kim S
    J Appl Clin Med Phys; 2016 Nov; 17(6):140-148. PubMed ID: 27929489
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dosimetric properties of equivalent-quality flattening filter-free (FFF) and flattened photon beams of Versa HD linear accelerator.
    Meshram MN; Pramanik S; Ranjith CP; Gopal SK; Dobhal R
    J Appl Clin Med Phys; 2016 May; 17(3):358-370. PubMed ID: 27167293
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Commissioning and dosimetric characteristics of TrueBeam system: composite data of three TrueBeam machines.
    Chang Z; Wu Q; Adamson J; Ren L; Bowsher J; Yan H; Thomas A; Yin FF
    Med Phys; 2012 Nov; 39(11):6981-7018. PubMed ID: 23127092
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An analytical formalism to calculate phantom scatter factors for flattening filter free (FFF) mode photon beams.
    Chung H; Prado KL; Yi BY
    Phys Med Biol; 2014 Feb; 59(4):951-60. PubMed ID: 24503449
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monte Carlo modeling of HD120 multileaf collimator on Varian TrueBeam linear accelerator for verification of 6X and 6X FFF VMAT SABR treatment plans.
    Bergman AM; Gete E; Duzenli C; Teke T
    J Appl Clin Med Phys; 2014 May; 15(3):4686. PubMed ID: 24892341
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of angular dependence for small-field dosimetry using seven different detectors.
    Kawata K; Ono T; Hirashima H; Tsuruta Y; Fujimoto T; Nakamura M; Nakata M
    Med Phys; 2023 Mar; 50(3):1274-1289. PubMed ID: 36583601
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.