These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 30594257)

  • 1. User-centered practicability analysis of two identification strategies in electrode arrays for FES induced hand motion in early stroke rehabilitation.
    Salchow-Hömmen C; Jankowski N; Valtin M; Schönijahn L; Böttcher S; Dähne F; Schauer T
    J Neuroeng Rehabil; 2018 Dec; 15(1):123. PubMed ID: 30594257
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A New Semi-Automatic Approach to Find Suitable Virtual Electrodes in Arrays Using an Interpolation Strategy.
    Salchow C; Valtin M; Seel T; Schauer T
    Eur J Transl Myol; 2016 Jun; 26(2):6029. PubMed ID: 27478567
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Temporal and Spatial Variability of Surface Motor Activation Zones in Hemiplegic Patients During Functional Electrical Stimulation Therapy Sessions.
    Malešević J; Štrbac M; Isaković M; Kojić V; Konstantinović L; Vidaković A; Dedijer Dujović S; Kostić M; Keller T
    Artif Organs; 2017 Nov; 41(11):E166-E177. PubMed ID: 29148131
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automatic determination of parameters for multipad functional electrical stimulation: application to hand opening and closing.
    Hoffmann U; Deinhofer M; Keller T
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():1859-63. PubMed ID: 23366275
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multi-contact functional electrical stimulation for hand opening: electrophysiologically driven identification of the optimal stimulation site.
    De Marchis C; Santos Monteiro T; Simon-Martinez C; Conforto S; Gharabaghi A
    J Neuroeng Rehabil; 2016 Mar; 13():22. PubMed ID: 26955873
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A multi-pad electrode based functional electrical stimulation system for restoration of grasp.
    Malešević NM; Popović Maneski LZ; Ilić V; Jorgovanović N; Bijelić G; Keller T; Popović DB
    J Neuroeng Rehabil; 2012 Sep; 9():66. PubMed ID: 23009589
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A decision support system for electrode shaping in multi-pad FES foot drop correction.
    Malešević J; Dedijer Dujović S; Savić AM; Konstantinović L; Vidaković A; Bijelić G; Malešević N; Keller T
    J Neuroeng Rehabil; 2017 Jul; 14(1):66. PubMed ID: 28673311
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Virtual Reality Rehabilitation With Functional Electrical Stimulation Improves Upper Extremity Function in Patients With Chronic Stroke: A Pilot Randomized Controlled Study.
    Lee SH; Lee JY; Kim MY; Jeon YJ; Kim S; Shin JH
    Arch Phys Med Rehabil; 2018 Aug; 99(8):1447-1453.e1. PubMed ID: 29505744
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Upper-limb stroke rehabilitation using electrode-array based functional electrical stimulation with sensing and control innovations.
    Kutlu M; Freeman CT; Hallewell E; Hughes AM; Laila DS
    Med Eng Phys; 2016 Apr; 38(4):366-79. PubMed ID: 26947097
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Feasibility study of a take-home array-based functional electrical stimulation system with automated setup for current functional electrical stimulation users with foot-drop.
    Prenton S; Kenney LP; Stapleton C; Cooper G; Reeves ML; Heller BW; Sobuh M; Barker AT; Healey J; Good TR; Thies SB; Howard D; Williamson T
    Arch Phys Med Rehabil; 2014 Oct; 95(10):1870-7. PubMed ID: 24845222
    [TBL] [Abstract][Full Text] [Related]  

  • 11. End-user and clinician perspectives on the viability of wearable functional electrical stimulation garments after stroke and spinal cord injury.
    Moineau B; Myers M; Ali SS; Popovic MR; Hitzig SL
    Disabil Rehabil Assist Technol; 2021 Apr; 16(3):241-250. PubMed ID: 31592679
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis of the movements generated by a multi-field functional electrical stimulation device for upper extremity rehabilitation.
    Martín-Odriozola A; Rodríguez-de-Pablo C; Caceres-Salegi A; García-Calleja A; Marín-Ojea JI; Hernández E; Imatz-Ojanguren E; Keller T; Zabaleta-Rekondo H
    Artif Organs; 2022 Oct; 46(10):2027-2033. PubMed ID: 35731175
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The application of precisely controlled functional electrical stimulation to the shoulder, elbow and wrist for upper limb stroke rehabilitation: a feasibility study.
    Meadmore KL; Exell TA; Hallewell E; Hughes AM; Freeman CT; Kutlu M; Benson V; Rogers E; Burridge JH
    J Neuroeng Rehabil; 2014 Jun; 11():105. PubMed ID: 24981060
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a functional hand orthosis combined with electrical stimulation adjunct to arm-hand rehabilitation in subacute stroke patients with a severely to moderately affected hand function.
    Franck JA; Smeets RJEM; Seelen HAM
    Disabil Rehabil; 2019 May; 41(10):1160-1168. PubMed ID: 29316821
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of the surface electrostimulation controlled by muscle contraction on the bioelectric muscle activity and restoration of the hand function in cerebral stroke patients.
    Krukowska J; Swiątek E; Sienkiewicz M; Czernicki J
    NeuroRehabilitation; 2014; 35(3):427-34. PubMed ID: 25227541
    [TBL] [Abstract][Full Text] [Related]  

  • 16. User experiences, preferences and choices relating to functional electrical stimulation and ankle foot orthoses for foot-drop after stroke.
    Bulley C; Shiels J; Wilkie K; Salisbury L
    Physiotherapy; 2011 Sep; 97(3):226-33. PubMed ID: 21820541
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimal Multifield Functional Electrical Stimulation Parameters for the "Turn on the Light" Task and Related Upper Limb Kinematics Repeatability in Poststroke Subjects.
    Sousa ASP; Mesquita IA; Costa da Silva CI; Silva A; Macedo R; Imatz-Ojanguren E; Hernandez E; Keller T; Moreira J; Pereira da Fonseca PF; Santos R
    Arch Phys Med Rehabil; 2021 Jun; 102(6):1180-1190. PubMed ID: 33253692
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Implanted functional electrical stimulation hand system in adolescents with spinal injuries: an evaluation.
    Mulcahey MJ; Betz RR; Smith BT; Weiss AA; Davis SE
    Arch Phys Med Rehabil; 1997 Jun; 78(6):597-607. PubMed ID: 9196467
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Neurorehabilitation with new functional electrical stimulation for hemiparetic upper extremity in stroke patients.
    Hara Y
    J Nippon Med Sch; 2008 Feb; 75(1):4-14. PubMed ID: 18360073
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A review of the design and clinical evaluation of the ShefStim array-based functional electrical stimulation system.
    Kenney LP; Heller BW; Barker AT; Reeves ML; Healey J; Good TR; Cooper G; Sha N; Prenton S; Liu A; Howard D
    Med Eng Phys; 2016 Nov; 38(11):1159-1165. PubMed ID: 27639656
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.