21. A biomechanical comparison of proximal femoral nails and locking proximal anatomic femoral plates in femoral fracture fixation: A study on synthetic bones. Ozkan K; Türkmen İ; Sahin A; Yildiz Y; Erturk S; Soylemez MS Indian J Orthop; 2015; 49(3):347-51. PubMed ID: 26015637 [TBL] [Abstract][Full Text] [Related]
22. The early failure of the gamma nail and the dynamic hip screw in femurs with a wide medullary canal. A biomechanical study of intertrochanteric fractures. Ceynowa M; Zerdzicki K; Klosowski P; Pankowski R; Rocławski M; Mazurek T Clin Biomech (Bristol); 2020 Jan; 71():201-207. PubMed ID: 31775090 [TBL] [Abstract][Full Text] [Related]
23. Intramedullary cortical bone strut improves the cyclic stability of osteoporotic proximal humeral fractures. Hsiao CK; Tsai YJ; Yen CY; Lee CH; Yang TY; Tu YK BMC Musculoskelet Disord; 2017 Feb; 18(1):64. PubMed ID: 28153021 [TBL] [Abstract][Full Text] [Related]
24. [Biomechanical comparative study on proximal femoral locking plate and Gamma3 for treatment of stable intertrochanteric fracture]. Jiang W; Liu Y; Yang L; Xu W; Liu S; Zhang D; Chen X; Wang H Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Sep; 28(9):1096-9. PubMed ID: 25509773 [TBL] [Abstract][Full Text] [Related]
25. A biomechanical comparison of various methods of stabilization of subtrochanteric fractures of the femur. Tencer AF; Johnson KD; Johnston DW; Gill K J Orthop Res; 1984; 2(3):297-305. PubMed ID: 6491820 [TBL] [Abstract][Full Text] [Related]
26. Mechanical comparison of endosteal substitution and lateral plate fixation in supracondylar fractures of the femur. Prayson MJ; Datta DK; Marshall MP J Orthop Trauma; 2001 Feb; 15(2):96-100. PubMed ID: 11232661 [TBL] [Abstract][Full Text] [Related]
27. Distal femoral fractures in the elderly: biomechanical analysis of a polyaxial angle-stable locking plate versus a retrograde intramedullary nail in a human cadaveric bone model. Bliemel C; Buecking B; Mueller T; Wack C; Koutras C; Beck T; Ruchholtz S; Zettl R Arch Orthop Trauma Surg; 2015 Jan; 135(1):49-58. PubMed ID: 25388863 [TBL] [Abstract][Full Text] [Related]
28. Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding Hip Screw and Percutaneous Compression Plate. Krischak GD; Augat P; Beck A; Arand M; Baier B; Blakytny R; Gebhard F; Claes L Clin Biomech (Bristol); 2007 Dec; 22(10):1112-8. PubMed ID: 17900766 [TBL] [Abstract][Full Text] [Related]
30. Cement augmentation of the proximal femoral nail antirotation for the treatment of osteoporotic pertrochanteric fractures--a biomechanical cadaver study. Fensky F; Nüchtern JV; Kolb JP; Huber S; Rupprecht M; Jauch SY; Sellenschloh K; Püschel K; Morlock MM; Rueger JM; Lehmann W Injury; 2013 Jun; 44(6):802-7. PubMed ID: 23545113 [TBL] [Abstract][Full Text] [Related]
31. Biomechanical analysis of four types of internal fixation in subtrochanteric fracture models. Wang J; Ma XL; Ma JX; Xing D; Yang Y; Zhu SW; Ma BY; Chen Y; Feng R; Jia HB; Yu JT Orthop Surg; 2014 May; 6(2):128-36. PubMed ID: 24890295 [TBL] [Abstract][Full Text] [Related]
32. Rotationally Stable Screw-Anchor With Locked Trochanteric Stabilizing Plate Versus Proximal Femoral Nail Antirotation in the Treatment of AO/OTA 31A2.2 Fracture: A Biomechanical Evaluation. Knobe M; Nagel P; Maier KJ; Gradl G; Buecking B; Sönmez TT; Modabber A; Prescher A; Pape HC J Orthop Trauma; 2016 Jan; 30(1):e12-8. PubMed ID: 26849388 [TBL] [Abstract][Full Text] [Related]
33. Current Concepts in Management of Distal Femur Fractures. Babhulkar S; Trikha V; Babhulkar S; Gavaskar AS Injury; 2024 Jun; 55 Suppl 2():111357. PubMed ID: 39098785 [TBL] [Abstract][Full Text] [Related]
34. Comparative biomechanical analysis of supracondylar femur fracture fixation: locked intramedullary nail versus 95-degree angled plate. David SM; Harrow ME; Peindl RD; Frick SL; Kellam JF J Orthop Trauma; 1997 Jul; 11(5):344-50. PubMed ID: 9294798 [TBL] [Abstract][Full Text] [Related]
35. Embedding the lateral end of the lag screw within the lateral wall in the repair of reverse obliquity intertrochanteric femur fracture. Hiragami K; Ishii J J Int Med Res; 2018 Mar; 46(3):1103-1108. PubMed ID: 29082791 [TBL] [Abstract][Full Text] [Related]
36. Fixation of Metacarpal Shaft Fractures: Biomechanical Comparison of Intramedullary Nail Crossed K-Wires and Plate-Screw Constructs. Curtis BD; Fajolu O; Ruff ME; Litsky AS Orthop Surg; 2015 Aug; 7(3):256-60. PubMed ID: 26311101 [TBL] [Abstract][Full Text] [Related]
37. Biomechanical evaluation of retrograde docking nailing to a total hip arthroplasty stem in a periprosthetic femur fracture model. Lenz M; Hofmann-Fliri L; Kasper LA; Varga P; Zderic I; Gehweiler D; Klos K; Hofmann GO; Stoffel K; Gueorguiev B Injury; 2021 Jan; 52(1):53-59. PubMed ID: 33129493 [TBL] [Abstract][Full Text] [Related]
38. Controlled study on Gamma nail and proximal femoral locking plate for unstable intertrochanteric femoral fractures with broken lateral wall. Han L; Liu JJ; Hu YG; Quan RF; Fang WL; Jin B; Lin WL Sci Rep; 2018 Jul; 8(1):11114. PubMed ID: 30042398 [TBL] [Abstract][Full Text] [Related]
39. The effect of implant overlap on the mechanical properties of the femur. Harris T; Ruth JT; Szivek J; Haywood B J Trauma; 2003 May; 54(5):930-5. PubMed ID: 12777906 [TBL] [Abstract][Full Text] [Related]
40. Biomechanics of Osteoporotic Fracture Care: Advances in Locking Plate and Intramedullary Nail Technology. Aneja A; Teasdall RJ; Graves ML J Orthop Trauma; 2021 Oct; 35(Suppl 5):S1-S5. PubMed ID: 34533494 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]