These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

202 related articles for article (PubMed ID: 30606215)

  • 21. The neck-shaft angle is the key factor for the positioning of calcar screw when treating proximal humeral fractures with a locking plate.
    Wang Q; Sheng N; Rui B; Chen Y
    Bone Joint J; 2020 Dec; 102-B(12):1629-1635. PubMed ID: 33249912
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Investigation of Kryptonite™ bone cement in hybrid screw configurations of locking plate humeral midshaft fixation: A study of surrogate bone model.
    Le TT; Vo HV; Webb LX
    J Orthop; 2016 Sep; 13(3):157-61. PubMed ID: 27408488
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Biomechanical behavior of three types of fixation in the two-part proximal humerus fracture without medial cortical support.
    di Tullio PO; Giordano V; Souto E; Assed H; Chequer JP; Belangero W; Mariolani JRL; Koch HA
    PLoS One; 2019; 14(7):e0220523. PubMed ID: 31361778
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The position and number of screws influence screw perforation of the humeral head in modern locking plates: a cadaver study.
    Erhardt JB; Stoffel K; Kampshoff J; Badur N; Yates P; Kuster MS
    J Orthop Trauma; 2012 Oct; 26(10):e188-92. PubMed ID: 22357093
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Is there any advantage in placing an additional calcar screw in locked nailing of proximal humeral fractures?
    Katthagen JC; Schwarze M; Bauer L; Meyer-Kobbe J; Voigt C; Hurschler C; Lill H
    Orthop Traumatol Surg Res; 2015 Jun; 101(4):431-5. PubMed ID: 25922285
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The calcar screw in angular stable plate fixation of proximal humeral fractures--a case study.
    Osterhoff G; Ossendorf C; Wanner GA; Simmen HP; Werner CM
    J Orthop Surg Res; 2011 Sep; 6():50. PubMed ID: 21943090
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Biomechanics of humerus fracture fixation by locking, cortical, and hybrid plating systems in a cadaver model.
    Sutherland GB; Creekmore T; Mukherjee DP; Ogden AL; Anissian L; Marymont JV
    Orthopedics; 2010 Aug; 33(8):. PubMed ID: 20704117
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The mechanical benefit of medial support screws in locking plating of proximal humerus fractures.
    Zhang W; Zeng L; Liu Y; Pan Y; Zhang W; Zhang C; Zeng B; Chen Y
    PLoS One; 2014; 9(8):e103297. PubMed ID: 25084520
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Biomechanical comparison of a proximal humeral locking plate using two methods of head fixation.
    Schumer RA; Muckley KL; Markert RJ; Prayson MJ; Heflin J; Konstantakos EK; Goswami T
    J Shoulder Elbow Surg; 2010 Jun; 19(4):495-501. PubMed ID: 20189837
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Screw configuration in proximal humerus plating has a significant impact on fixation failure risk predicted by finite element models.
    Fletcher JWA; Windolf M; Richards RG; Gueorguiev B; Varga P
    J Shoulder Elbow Surg; 2019 Sep; 28(9):1816-1823. PubMed ID: 31036421
    [TBL] [Abstract][Full Text] [Related]  

  • 31. How can medial support for proximal humeral fractures be achieved when positioning of regular calcar screws is challenging? Slotting and off-axis fixation strategies.
    Xu J; Zhan S; Ling M; Jiang D; Hu H; Sheng J; Ding J
    J Shoulder Elbow Surg; 2022 Apr; 31(4):782-791. PubMed ID: 34619347
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Influence of plate material and screw design on stiffness and ultimate load of locked plating in osteoporotic proximal humeral fractures.
    Katthagen JC; Schwarze M; Warnhoff M; Voigt C; Hurschler C; Lill H
    Injury; 2016 Mar; 47(3):617-24. PubMed ID: 26804939
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Biomechanical analysis of plate osteosynthesis systems for proximal humerus fractures.
    Lever JP; Aksenov SA; Zdero R; Ahn H; McKee MD; Schemitsch EH
    J Orthop Trauma; 2008 Jan; 22(1):23-9. PubMed ID: 18176161
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison of three different fixation constructs for radial neck fractures: a biomechanical study.
    Chen H; Wu D; Pan T; Pan J; Zhang R; Shi X
    J Orthop Surg Res; 2017 Nov; 12(1):175. PubMed ID: 29137658
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The proximal humeral locking plate positioning to the pectoralis major tendon in achieving the proper calcar screw location: a cadaveric study.
    Kulkamthorn N; Rungrattanawilai N; Tarunotai T; Chuvetsereporn N; Chansela P; Phruetthiphat OA
    J Orthop Surg Res; 2022 Jan; 17(1):6. PubMed ID: 34983577
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Which additional augmented fixation procedure decreases surgical failure after proximal humeral fracture with medial comminution: fibular allograft or inferomedial screws?
    Kim DS; Lee DH; Chun YM; Shin SJ
    J Shoulder Elbow Surg; 2018 Oct; 27(10):1852-1858. PubMed ID: 29735375
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques.
    Edwards SL; Wilson NA; Zhang LQ; Flores S; Merk BR
    J Bone Joint Surg Am; 2006 Oct; 88(10):2258-64. PubMed ID: 17015605
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The role of medial comminution and calcar restoration in varus collapse of proximal humeral fractures treated with locking plates.
    Ponce BA; Thompson KJ; Raghava P; Eberhardt AW; Tate JP; Volgas DA; Stannard JP
    J Bone Joint Surg Am; 2013 Aug; 95(16):e113(1-7). PubMed ID: 23965707
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Biomechanical evaluation of hybrid double plate osteosynthesis using a locking plate and an inverted third tubular plate for the treatment of proximal humeral fractures.
    Theopold J; Schleifenbaum S; Müller M; Werner M; Hammer N; Josten C; Hepp P
    PLoS One; 2018; 13(10):e0206349. PubMed ID: 30372476
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A mechanical comparison of the locking compression plate (LCP) and the low contact-dynamic compression plate (DCP) in an osteoporotic bone model.
    Snow M; Thompson G; Turner PG
    J Orthop Trauma; 2008 Feb; 22(2):121-5. PubMed ID: 18349780
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.