BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

240 related articles for article (PubMed ID: 30609205)

  • 1. Multi-observer contouring of male pelvic anatomy: Highly variable agreement across conventional and emerging structures of interest.
    Roach D; Holloway LC; Jameson MG; Dowling JA; Kennedy A; Greer PB; Krawiec M; Rai R; Denham J; De Leon J; Lim K; Berry ME; White RT; Bydder SA; Tan HT; Croker JD; McGrath A; Matthews J; Smeenk RJ; Ebert MA
    J Med Imaging Radiat Oncol; 2019 Apr; 63(2):264-271. PubMed ID: 30609205
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Magnetic resonance imaging for prostate bed radiotherapy planning: An inter- and intra-observer variability study.
    Barkati M; Simard D; Taussky D; Delouya G
    J Med Imaging Radiat Oncol; 2016 Apr; 60(2):255-9. PubMed ID: 26568515
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Technology assessment of automated atlas based segmentation in prostate bed contouring.
    Hwee J; Louie AV; Gaede S; Bauman G; D'Souza D; Sexton T; Lock M; Ahmad B; Rodrigues G
    Radiat Oncol; 2011 Sep; 6():110. PubMed ID: 21906279
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Correlations between contouring similarity metrics and simulated treatment outcome for prostate radiotherapy.
    Roach D; Jameson MG; Dowling JA; Ebert MA; Greer PB; Kennedy AM; Watt S; Holloway LC
    Phys Med Biol; 2018 Jan; 63(3):035001. PubMed ID: 29300184
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration.
    Parker CC; Damyanovich A; Haycocks T; Haider M; Bayley A; Catton CN
    Radiother Oncol; 2003 Feb; 66(2):217-24. PubMed ID: 12648794
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences.
    Dowling JA; Sun J; Pichler P; Rivest-Hénault D; Ghose S; Richardson H; Wratten C; Martin J; Arm J; Best L; Chandra SS; Fripp J; Menk FW; Greer PB
    Int J Radiat Oncol Biol Phys; 2015 Dec; 93(5):1144-53. PubMed ID: 26581150
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intra- and inter-observer variability in contouring prostate and seminal vesicles: implications for conformal treatment planning.
    Fiorino C; Reni M; Bolognesi A; Cattaneo GM; Calandrino R
    Radiother Oncol; 1998 Jun; 47(3):285-92. PubMed ID: 9681892
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Changes in target volumes definition by using MRI for prostate bed radiotherapy planning--preliminary results].
    Sefrová J; Paluska ; Odrázka K; Belobradek Z; Hoffmann P; Prosvic P; Brod'ák M; Louda M; Macingová Z; Vosmik M
    Klin Onkol; 2010; 23(4):256-63. PubMed ID: 20806824
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Inter-observer variability in contouring the penile bulb on CT images for prostate cancer treatment planning.
    Perna L; Cozzarini C; Maggiulli E; Fellin G; Rancati T; Valdagni R; Vavassori V; Villa S; Fiorino C
    Radiat Oncol; 2011 Sep; 6():123. PubMed ID: 21943002
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A pair of deep learning auto-contouring models for prostate cancer patients injected with a radio-transparent versus radiopaque hydrogel spacer.
    Wang Y; Boyd G; Zieminski S; Kamran SC; Zietman AL; Miyamoto DT; Kirk MC; Efstathiou JA
    Med Phys; 2023 Jun; 50(6):3324-3337. PubMed ID: 36940384
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of therapeutic radiographer contouring for magnetic resonance image guided online adaptive prostate radiotherapy.
    Adair Smith G; Dunlop A; Alexander SE; Barnes H; Casey F; Chick J; Gunapala R; Herbert T; Lawes R; Mason SA; Mitchell A; Mohajer J; Murray J; Nill S; Patel P; Pathmanathan A; Sritharan K; Sundahl N; Tree AC; Westley R; Williams B; McNair HA
    Radiother Oncol; 2023 Mar; 180():109457. PubMed ID: 36608770
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rectum contouring variability in patients treated for prostate cancer: impact on rectum dose-volume histograms and normal tissue complication probability.
    Fiorino C; Vavassori V; Sanguineti G; Bianchi C; Cattaneo GM; Piazzolla A; Cozzarini C
    Radiother Oncol; 2002 Jun; 63(3):249-55. PubMed ID: 12142088
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Autosegmentation of prostate anatomy for radiation treatment planning using deep decision forests of radiomic features.
    Macomber MW; Phillips M; Tarapov I; Jena R; Nori A; Carter D; Folgoc LL; Criminisi A; Nyflot MJ
    Phys Med Biol; 2018 Nov; 63(23):235002. PubMed ID: 30465543
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dedicated MRI simulation for cervical cancer radiation treatment planning: Assessing the impact on clinical target volume delineation.
    Veera J; Lim K; Dowling JA; O'Connor C; Holloway LC; Vinod SK
    J Med Imaging Radiat Oncol; 2019 Apr; 63(2):236-243. PubMed ID: 30506944
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluating the relationship between contouring variability and modelled treatment outcome for prostate bed radiotherapy.
    Le Bao V; Haworth A; Dowling J; Walker A; Arumugam S; Jameson M; Chlap P; Wiltshire K; Keats S; Cloak K; Sidhom M; Kneebone A; Holloway L
    Phys Med Biol; 2024 Apr; 69(8):. PubMed ID: 38471173
    [No Abstract]   [Full Text] [Related]  

  • 16. Clinical validation of an automatic atlas-based segmentation tool for male pelvis CT images.
    Casati M; Piffer S; Calusi S; Marrazzo L; Simontacchi G; Di Cataldo V; Greto D; Desideri I; Vernaleone M; Francolini G; Livi L; Pallotta S
    J Appl Clin Med Phys; 2022 Mar; 23(3):e13507. PubMed ID: 35064746
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Feasibility of CBCT-based target and normal structure delineation in prostate cancer radiotherapy: multi-observer and image multi-modality study.
    Lütgendorf-Caucig C; Fotina I; Stock M; Pötter R; Goldner G; Georg D
    Radiother Oncol; 2011 Feb; 98(2):154-61. PubMed ID: 21176984
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of prostate delineation on multimodality imaging for MR-guided radiotherapy.
    Pathmanathan AU; McNair HA; Schmidt MA; Brand DH; Delacroix L; Eccles CL; Gordon A; Herbert T; van As NJ; Huddart RA; Tree AC
    Br J Radiol; 2019 Mar; 92(1095):20180948. PubMed ID: 30676772
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Creation of RTOG compliant patient CT-atlases for automated atlas based contouring of local regional breast and high-risk prostate cancers.
    Velker VM; Rodrigues GB; Dinniwell R; Hwee J; Louie AV
    Radiat Oncol; 2013 Jul; 8():188. PubMed ID: 23885662
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Automatic AI-based contouring of prostate MRI for online adaptive radiotherapy.
    Nachbar M; Lo Russo M; Gani C; Boeke S; Wegener D; Paulsen F; Zips D; Roque T; Paragios N; Thorwarth D
    Z Med Phys; 2024 May; 34(2):197-207. PubMed ID: 37263911
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.