690 related articles for article (PubMed ID: 30620418)
1. High-frequency (20-MHz) high-intensity focused ultrasound (HIFU) system for dermal intervention: Preclinical evaluation in skin equivalents.
Bove T; Zawada T; Serup J; Jessen A; Poli M
Skin Res Technol; 2019 Mar; 25(2):217-228. PubMed ID: 30620418
[TBL] [Abstract][Full Text] [Related]
2. High-frequency (20 MHz) high-intensity focused ultrasound system for dermal intervention: A 12-week local tolerance study in minipigs.
Soegaard S; Aarup V; Serup J; Bove T; Zawada T; Jessen A; Poli M
Skin Res Technol; 2020 Mar; 26(2):241-254. PubMed ID: 31541524
[TBL] [Abstract][Full Text] [Related]
3. Morphometric analysis of high-intensity focused ultrasound-induced lipolysis on cadaveric abdominal and thigh skin.
Lee S; Kim HJ; Park HJ; Kim HM; Lee SH; Cho SB
Lasers Med Sci; 2017 Jul; 32(5):1143-1151. PubMed ID: 28451817
[TBL] [Abstract][Full Text] [Related]
4. Determining temperature distribution in tissue in the focal plane of the high (>100 W/cm(2)) intensity focused ultrasound beam using phase shift of ultrasound echoes.
Karwat P; Kujawska T; Lewin PA; Secomski W; Gambin B; Litniewski J
Ultrasonics; 2016 Feb; 65():211-9. PubMed ID: 26498063
[TBL] [Abstract][Full Text] [Related]
5. Coagulation and ablation patterns of high-intensity focused ultrasound on a tissue-mimicking phantom and cadaveric skin.
Kim HJ; Kim HG; Zheng Z; Park HJ; Yoon JH; Oh W; Lee CW; Cho SB
Lasers Med Sci; 2015 Dec; 30(9):2251-8. PubMed ID: 26341380
[TBL] [Abstract][Full Text] [Related]
6. Improved intercostal HIFU ablation using a phased array transducer based on Fermat's spiral and Voronoi tessellation: A numerical evaluation.
Ramaekers P; Ries M; Moonen CT; de Greef M
Med Phys; 2017 Mar; 44(3):1071-1088. PubMed ID: 28058731
[TBL] [Abstract][Full Text] [Related]
7. Annular phased array transducer for preclinical testing of anti-cancer drug efficacy on small animals.
Kujawska T; Secomski W; Byra M; Postema M; Nowicki A
Ultrasonics; 2017 Apr; 76():92-98. PubMed ID: 28086110
[TBL] [Abstract][Full Text] [Related]
8. Dependence of Boiling Histotripsy Treatment Efficiency on HIFU Frequency and Focal Pressure Levels.
Khokhlova TD; Haider YA; Maxwell AD; Kreider W; Bailey MR; Khokhlova VA
Ultrasound Med Biol; 2017 Sep; 43(9):1975-1985. PubMed ID: 28641910
[TBL] [Abstract][Full Text] [Related]
9. High intensity focused ultrasound (HIFU) focal spot localization using harmonic motion imaging (HMI).
Han Y; Hou GY; Wang S; Konofagou E
Phys Med Biol; 2015 Aug; 60(15):5911-24. PubMed ID: 26184846
[TBL] [Abstract][Full Text] [Related]
10. Frequency considerations for deep ablation with high-intensity focused ultrasound: A simulation study.
Ellens N; Hynynen K
Med Phys; 2015 Aug; 42(8):4896-10. PubMed ID: 26233216
[TBL] [Abstract][Full Text] [Related]
11. Interleaved Mapping of Temperature and Longitudinal Relaxation Rate to Monitor Drug Delivery During Magnetic Resonance-Guided High-Intensity Focused Ultrasound-Induced Hyperthermia.
Kneepkens E; Heijman E; Keupp J; Weiss S; Nicolay K; Grüll H
Invest Radiol; 2017 Oct; 52(10):620-630. PubMed ID: 28598900
[TBL] [Abstract][Full Text] [Related]
12. Design and evaluation of a transesophageal HIFU probe for ultrasound-guided cardiac ablation: simulation of a HIFU mini-maze procedure and preliminary ex vivo trials.
Constanciel E; N'Djin WA; Bessière F; Chavrier F; Grinberg D; Vignot A; Chevalier P; Chapelon JY; Lafon C
IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Sep; 60(9):1868-83. PubMed ID: 24658718
[TBL] [Abstract][Full Text] [Related]
13. Non-Invasive Targeted Peripheral Nerve Ablation Using 3D MR Neurography and MRI-Guided High-Intensity Focused Ultrasound (MR-HIFU): Pilot Study in a Swine Model.
Huisman M; Staruch RM; Ladouceur-Wodzak M; van den Bosch MA; Burns DK; Chhabra A; Chopra R
PLoS One; 2015; 10(12):e0144742. PubMed ID: 26659073
[TBL] [Abstract][Full Text] [Related]
14. Real-time monitoring of high-intensity focused ultrasound thermal therapy using the manifold learning method.
Rangraz P; Behnam H; Sobhebidari P; Tavakkoli J
Ultrasound Med Biol; 2014 Dec; 40(12):2841-50. PubMed ID: 25438863
[TBL] [Abstract][Full Text] [Related]
15. High-intensity focused ultrasound treatment for skin: ex vivo evaluation.
Park JH; Lim SD; Oh SH; Lee JH; Yeo UC
Skin Res Technol; 2017 Aug; 23(3):384-391. PubMed ID: 27868241
[TBL] [Abstract][Full Text] [Related]
16. Real-time monitoring of high-intensity focused ultrasound treatment using axial strain and axial-shear strain elastograms.
Xia R; Thittai AK
Ultrasound Med Biol; 2014 Mar; 40(3):485-95. PubMed ID: 24361216
[TBL] [Abstract][Full Text] [Related]
17. A feasibility study of temperature rise measurement in a tissue phantom as an alternative way for characterization of the therapeutic high intensity focused ultrasonic field.
Chen D; Fan T; Zhang D; Wu J
Ultrasonics; 2009 Dec; 49(8):733-42. PubMed ID: 19576607
[TBL] [Abstract][Full Text] [Related]
18. HIFU-induced cavitation and heating in ex vivo porcine subcutaneous fat.
Kyriakou Z; Corral-Baques MI; Amat A; Coussios CC
Ultrasound Med Biol; 2011 Apr; 37(4):568-79. PubMed ID: 21371810
[TBL] [Abstract][Full Text] [Related]
19. Real-time passive acoustic monitoring of HIFU-induced tissue damage.
Nandlall SD; Jackson E; Coussios CC
Ultrasound Med Biol; 2011 Jun; 37(6):922-34. PubMed ID: 21601136
[TBL] [Abstract][Full Text] [Related]
20. Adaptive HIFU noise cancellation for simultaneous therapy and imaging using an integrated HIFU/imaging transducer.
Jeong JS; Cannata JM; Shung KK
Phys Med Biol; 2010 Apr; 55(7):1889-902. PubMed ID: 20224162
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]