BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 30624077)

  • 1. Self-expanding CENTERA valve for the treatment of severe, symptomatic aortic stenosis.
    Brennan PF; Spence MS
    Future Cardiol; 2019 Mar; 15(2):79-84. PubMed ID: 30624077
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Self-Expanding Transcatheter Aortic Valve System for Symptomatic High-Risk Patients With Severe Aortic Stenosis.
    Reichenspurner H; Schaefer A; Schäfer U; Tchétché D; Linke A; Spence MS; Søndergaard L; LeBreton H; Schymik G; Abdel-Wahab M; Leipsic J; Walters DL; Worthley S; Kasel M; Windecker S
    J Am Coll Cardiol; 2017 Dec; 70(25):3127-3136. PubMed ID: 29268926
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 1-Year Outcomes of the CENTERA-EU Trial Assessing a Novel Self-Expanding Transcatheter Heart Valve.
    Tchétché D; Windecker S; Kasel AM; Schaefer U; Worthley S; Linke A; Abdel-Wahab M; Le Breton H; Søndergaard L; Spence MS; Petronio S; Baumgartner H; Hovorka T; Blanke P; Reichenspurner H
    JACC Cardiovasc Interv; 2019 Apr; 12(7):673-680. PubMed ID: 30947942
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Computed Tomography-Based Oversizing Degrees and Incidence of Paravalvular Regurgitation of a New Generation Transcatheter Heart Valve.
    Blanke P; Pibarot P; Hahn R; Weissman N; Kodali S; Thourani V; Parvataneni R; Dvir D; Naoum C; Nørgaard BL; Douglas P; Jaber W; Khalique OK; Jilaihawi H; Mack M; Smith C; Leon M; Webb J; Leipsic J
    JACC Cardiovasc Interv; 2017 Apr; 10(8):810-820. PubMed ID: 28427598
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Relationship of Annular Sizing Using Multidetector Computed Tomographic Imaging and Clinical Outcomes After Self-Expanding CoreValve Transcatheter Aortic Valve Replacement.
    Popma JJ; Gleason TG; Yakubov SJ; Harrison JK; Forrest JK; Maini B; Ruiz CE; Pinto DS; Costa M; Resar J; Conte J; Crestanello J; Chang Y; Oh JK; Reardon MJ; Adams DH
    Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27369803
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transfemoral aortic valve implantation is more successful with the Edwards Sapien 3 compared with the Edwards XT for the treatment of symptomatic severe aortic stenosis.
    Gonska B; Seeger J; Junker A; Rodewald C; Trepte U; Scharnbeck D; Rottbauer W; Wöhrle J
    Arch Cardiovasc Dis; 2018; 111(8-9):470-479. PubMed ID: 29128473
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transcatheter aortic valve replacement with a new self-expanding transcatheter heart valve and motorized delivery system.
    Binder RK; Schäfer U; Kuck KH; Wood DA; Moss R; Leipsic J; Toggweiler S; Freeman M; Ostry AJ; Frerker C; Willson AB; Webb JG
    JACC Cardiovasc Interv; 2013 Mar; 6(3):301-7. PubMed ID: 23517843
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Early Outcomes With the Evolut PRO Repositionable Self-Expanding Transcatheter Aortic Valve With Pericardial Wrap.
    Forrest JK; Mangi AA; Popma JJ; Khabbaz K; Reardon MJ; Kleiman NS; Yakubov SJ; Watson D; Kodali S; George I; Tadros P; Zorn GL; Brown J; Kipperman R; Saul S; Qiao H; Oh JK; Williams MR
    JACC Cardiovasc Interv; 2018 Jan; 11(2):160-168. PubMed ID: 29348010
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transfemoral aortic valve implantation with new-generation devices: the repositionable Lotus vs. the balloon-expandable Edwards Sapien 3 valve.
    Nai Fovino L; Badawy MRA; Fraccaro C; D'Onofrio A; Purita PAM; Frigo AC; Tellaroli P; Mauro A; Tusa M; Napodano M; Gerosa G; Iliceto S; Bedogni F; AbdelRheim AER; Tarantini G
    J Cardiovasc Med (Hagerstown); 2018 Nov; 19(11):655-663. PubMed ID: 30299408
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Implantation and 30-Day Follow-Up on All 4 Valve Sizes Within the Portico Transcatheter Aortic Bioprosthetic Family.
    Möllmann H; Linke A; Holzhey DM; Walther T; Manoharan G; Schäfer U; Heinz-Kuck K; Van Boven AJ; Redwood SR; Kovac J; Butter C; Søndergaard L; Lauten A; Schymik G; Worthley SG
    JACC Cardiovasc Interv; 2017 Aug; 10(15):1538-1547. PubMed ID: 28797431
    [TBL] [Abstract][Full Text] [Related]  

  • 11. First North American experience with the transfemoral ACURATE-neo
    Bagur R; Teefy PJ; Kiaii B; Diamantouros P; Chu MWA
    Catheter Cardiovasc Interv; 2017 Jul; 90(1):130-138. PubMed ID: 27677241
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Early Clinical Outcomes After Transcatheter Aortic Valve Replacement Using a Novel Self-Expanding Bioprosthesis in Patients With Severe Aortic Stenosis Who Are Suboptimal for Surgery: Results of the Evolut R U.S. Study.
    Popma JJ; Reardon MJ; Khabbaz K; Harrison JK; Hughes GC; Kodali S; George I; Deeb GM; Chetcuti S; Kipperman R; Brown J; Qiao H; Slater J; Williams MR
    JACC Cardiovasc Interv; 2017 Feb; 10(3):268-275. PubMed ID: 28183466
    [TBL] [Abstract][Full Text] [Related]  

  • 13. 30-Day and 1-Year Outcomes With HYDRA Self-Expanding Transcatheter Aortic Valve: The Hydra CE Study.
    Aidietis A; Srimahachota S; Dabrowski M; Bilkis V; Buddhari W; Cheung GSH; Nair RK; Mussayev AA; Mattummal S; Chandra P; Mahajan AU; Chmielak Z; Govindan SC; Jose J; Hiremath MS; Chandra S; Shetty R; Mohanan S; John JF; Mehrotra S; Søndergaard L
    JACC Cardiovasc Interv; 2022 Jan; 15(1):93-104. PubMed ID: 34991828
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of outcomes using balloon-expandable versus self-expanding transcatheter prostheses according to the extent of aortic valve calcification.
    Kim WK; Blumenstein J; Liebetrau C; Rolf A; Gaede L; Van Linden A; Arsalan M; Doss M; Tijssen JGP; Hamm CW; Walther T; Möllmann H
    Clin Res Cardiol; 2017 Dec; 106(12):995-1004. PubMed ID: 28795259
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improving outcomes: case-matched comparison of novel second-generation versus first-generation self-expandable transcatheter heart valves.
    Schaefer A; Treede H; Schoen G; Deuschl F; Schofer N; Schneeberger Y; Blankenberg S; Reichenspurner H; Schaefer U; Conradi L
    Eur J Cardiothorac Surg; 2016 Aug; 50(2):368-73. PubMed ID: 26888463
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transcatheter aortic valve implantation (TAVI) in 2018: recent advances and future development.
    Hecker F; Arsalan M; Kim WK; Walther T
    Minerva Cardioangiol; 2018 Jun; 66(3):314-328. PubMed ID: 29072064
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Procedural and 30-day clinical outcomes following transcatheter aortic valve replacement with lotus valve: Results of the RELEVANT study.
    Montone RA; Testa L; Fraccaro C; Montorfano M; Castriota F; Nerla R; Angelillis M; Tusa M; Giannini F; Garatti A; Tarantini G; Petronio AS; Brambilla N; Bedogni F
    Catheter Cardiovasc Interv; 2017 Dec; 90(7):1206-1211. PubMed ID: 28145039
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The JUPITER registry: 1-year results of transapical aortic valve implantation using a second-generation transcatheter heart valve in patients with aortic stenosis.
    Silaschi M; Treede H; Rastan AJ; Baumbach H; Beyersdorf F; Kappert U; Eichinger W; Rüter F; de Kroon TL; Lange R; Ensminger S; Wendler O
    Eur J Cardiothorac Surg; 2016 Nov; 50(5):874-881. PubMed ID: 27242354
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 1-Year Results in Patients Undergoing Transcatheter Aortic Valve Replacement With Failed Surgical Bioprostheses.
    Deeb GM; Chetcuti SJ; Reardon MJ; Patel HJ; Grossman PM; Schreiber T; Forrest JK; Bajwa TK; O'Hair DP; Petrossian G; Robinson N; Katz S; Hartman A; Dauerman HL; Schmoker J; Khabbaz K; Watson DR; Yakubov SJ; Oh JK; Li S; Kleiman NS; Adams DH; Popma JJ
    JACC Cardiovasc Interv; 2017 May; 10(10):1034-1044. PubMed ID: 28521921
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of the fully repositionable and retrievable Boston Lotus and direct flow medical valves for the treatment of severe aortic stenosis: A single center experience.
    Giannini F; Latib A; Montorfano M; Ruparelia N; Romano V; Longoni M; Ferri L; Jabbour R; Mangieri A; Regazzoli D; Ancona M; Buzzatti N; Azzalini L; Tanaka A; Agricola E; Chieffo A; Alfieri O; Colombo A
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):966-974. PubMed ID: 28941127
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.