These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 30624077)

  • 21. First experience with transfemoral transcatheter aortic valve implantation without prior balloon pre-dilatation using a latest generation repositionable and retrievable transcatheter heart valve†.
    Schaefer A; Harmel E; Seiffert M; Reichart D; Deuschl F; Schofer N; Schneeberger Y; Blankenberg S; Reichenspurner H; Schaefer U; Conradi L
    Interact Cardiovasc Thorac Surg; 2017 May; 24(5):659-662. PubMed ID: 28329312
    [TBL] [Abstract][Full Text] [Related]  

  • 22. TAVI with current CE-marked devices: strategies for optimal sizing and valve delivery.
    van Gils L; Tchetche D; Latib A; Sgroi C; Manoharan G; Möllmann H; Van Mieghem NM
    EuroIntervention; 2016 Sep; 12(Y):Y22-7. PubMed ID: 27640026
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Self-Expanding Transcatheter Aortic Valve Replacement Versus Surgical Valve Replacement in Patients at High Risk for Surgery: A Study of Echocardiographic Change and Risk Prediction.
    Little SH; Oh JK; Gillam L; Sengupta PP; Orsinelli DA; Cavalcante JL; Chang JD; Adams DH; Zorn GL; Pollak AW; Abdelmoneim SS; Reardon MJ; Qiao H; Popma JJ
    Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27313280
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Transcatheter Aortic Valve Implantation in High-Risk/Inoperable Patients: Repositionable versus Non-Repositionable Self-Expanding Valve.
    Veulemans V; Sötemann DB; Kleinebrecht L; Keymel S; Jung C; Zeus T; Kelm M; Westenfeld R
    J Heart Valve Dis; 2017 Jul; 26(4):405-412. PubMed ID: 29302939
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Computed tomography-based oversizing and incidence of paravalvular aortic regurgitation and permanent pacemaker implantation with a new-generation self-expanding transcatheter heart valve.
    Kim U; Blanke P; Windecker S; Kasel AM; Schäfer U; Walters D; Linke A; Le Breton H; Schymik G; Spence MS; Søndergaard L; Abdel-Wahab M; Worthley S; Tchétché D; Reichenspurner H; Ohana M; Sellers SL; Leipsic JA
    EuroIntervention; 2018 Aug; 14(5):e511-e518. PubMed ID: 29741486
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Transcatheter aortic valve implantation in patients with small aortic annuli using a 20 mm balloon-expanding valve.
    Puri R; Byrne J; Muller R; Baumbach H; Eltchaninoff H; Redwood S; Cheema A; Dubois C; Ihlberg L; Wijeysundera HC; Cerillo A; Götberg M; Klaaborg KE; Pelletier M; Blanco-Mata R; Edwards R; Gandolfo C; Muir D; Meucci F; Sinning JM; Stella P; Veulemans V; Virtanen M; Regueiro A; Thoenes M; Pibarot P; Pelletier-Beaumont E; Rodés-Cabau J
    Heart; 2017 Jan; 103(2):148-153. PubMed ID: 27534978
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Hemodynamic classification of paravalvular leakage after transcatheter aortic valve implantation compared with angiographic or echocardiographic classification for prediction of 1-year mortality.
    Schoechlin S; Brennemann T; Allali A; Ruile P; Jander N; Allgeier M; Gick M; Richardt G; Neumann FJ; Abdel-Wahab M
    Catheter Cardiovasc Interv; 2018 May; 91(6):E56-E63. PubMed ID: 29105984
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Transcatheter aortic valve implantation with a Sapien 3 Commander 20 mm valves in patients with degenerated 19 mm bioprosthetic aortic valve.
    Loyalka P; Nascimbene A; Schechter M; Petrovic M; Sundara Raman A; Gregoric ID; Kar B
    Catheter Cardiovasc Interv; 2017 Jun; 89(7):1280-1285. PubMed ID: 27696659
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Transcatheter Aortic Valve Replacement: Comprehensive Review and Present Status.
    Arora S; Misenheimer JA; Ramaraj R
    Tex Heart Inst J; 2017 Feb; 44(1):29-38. PubMed ID: 28265210
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Early aortic transcatheter heart valve thrombosis: diagnostic value of contrast-enhanced multidetector computed tomography.
    Leetmaa T; Hansson NC; Leipsic J; Jensen K; Poulsen SH; Andersen HR; Jensen JM; Webb J; Blanke P; Tang M; Nørgaard BL
    Circ Cardiovasc Interv; 2015 Apr; 8(4):. PubMed ID: 25873726
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Outcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure.
    Barbanti M; Webb JG; Tamburino C; Van Mieghem NM; Makkar RR; Piazza N; Latib A; Sinning JM; Won-Keun K; Bleiziffer S; Bedogni F; Kapadia S; Tchetche D; Rodés-Cabau J; Fiorina C; Nombela-Franco L; De Marco F; de Jaegere PP; Chakravarty T; Vaquerizo B; Colombo A; Svensson L; Lange R; Nickenig G; Möllmann H; Walther T; Della Rosa F; Elhmidi Y; Dvir D; Brambilla N; Immè S; Sgroi C; Gulino S; Todaro D; Pilato G; Petronio AS; Tamburino C
    Circ Cardiovasc Interv; 2016 Sep; 9(9):. PubMed ID: 27578840
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Low permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.
    Krackhardt F; Kherad B; Krisper M; Pieske B; Laule M; Tschöpe C
    Cardiol J; 2017; 24(3):250-258. PubMed ID: 28248410
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The balloon-expandable Edwards Sapien 3 valve is superior to the self-expanding Medtronic CoreValve in patients with severe aortic stenosis undergoing transfemoral aortic valve implantation.
    Gonska B; Seeger J; Baarts J; Rodewald C; Scharnbeck D; Rottbauer W; Wöhrle J
    J Cardiol; 2017 Jun; 69(6):877-882. PubMed ID: 27614379
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Transfemoral Aortic Valve Implantation with the New Edwards Sapien 3 Valve for Treatment of Severe Aortic Stenosis-Impact of Valve Size in a Single Center Experience.
    Wöhrle J; Gonska B; Rodewald C; Seeger J; Scharnbeck D; Rottbauer W
    PLoS One; 2016; 11(3):e0151247. PubMed ID: 27003573
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Transcatheter aortic valve implantation with the new balloon-expandable Sapien 3 versus Sapien XT valve system: a propensity score-matched single-center comparison.
    Nijhoff F; Abawi M; Agostoni P; Ramjankhan FZ; Doevendans PA; Stella PR
    Circ Cardiovasc Interv; 2015 Jun; 8(6):e002408. PubMed ID: 26033967
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Outcomes After Transcatheter Aortic Valve Replacement Using a Novel Balloon-Expandable Transcatheter Heart Valve: A Single-Center Experience.
    Husser O; Pellegrini C; Kessler T; Burgdorf C; Thaller H; Mayr NP; Ott I; Kasel AM; Schunkert H; Kastrati A; Hengstenberg C
    JACC Cardiovasc Interv; 2015 Dec; 8(14):1809-16. PubMed ID: 26718512
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Aortic Regurgitation after TAVR: From Bad to Worse.
    Hiltrop N; Adriaenssens T; Herijgers P; Dubois C
    J Heart Valve Dis; 2016 Mar; 25(2):182-184. PubMed ID: 27989062
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Conduction recovery and avoidance of permanent pacing after transcatheter aortic valve implantation.
    Marzahn C; Koban C; Seifert M; Isotani A; Neuß M; Hölschermann F; Butter C
    J Cardiol; 2018 Jan; 71(1):101-108. PubMed ID: 28818562
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Prospective comparison between three TAVR devices: ACURATE neo vs. CoreValve vs. SAPIEN XT. A single heart team experience in patients with severe aortic stenosis.
    Jatene T; Castro-Filho A; Meneguz-Moreno RA; Siqueira DA; Abizaid AAC; Ramos AIO; Arrais M; Le Bihan DCS; Barretto RBM; Moreira AC; Sousa AGMR; Eduardo Sousa J
    Catheter Cardiovasc Interv; 2017 Jul; 90(1):139-146. PubMed ID: 28029207
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A Strategy of Underexpansion and Ad Hoc Post-Dilation of Balloon-Expandable Transcatheter Aortic Valves in Patients at Risk of Annular Injury: Favorable Mid-Term Outcomes.
    Tan JS; Leipsic J; Perlman G; Stub D; Dvir D; Hansson NC; Norgaard BL; Blanke P; Cheung A; Ye J; Thompson CR; Moss RR; Lauck S; Wood D; Webb J
    JACC Cardiovasc Interv; 2015 Nov; 8(13):1727-32. PubMed ID: 26476612
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.