These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 30626991)

  • 41. Snapshot imaging polarimeter using modified Savart polariscopes.
    Cao Q; Zhang C; DeHoog E
    Appl Opt; 2012 Aug; 51(24):5791-6. PubMed ID: 22907005
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Single-pulse, Kerr-effect Mueller matrix LiDAR polarimeter.
    Keyser CK; Martin RK; Lopez-Aviles H; Nguyen K; Adams AM; Christodoulides D
    Opt Express; 2020 Apr; 28(9):13694-13713. PubMed ID: 32403839
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Intrinsic coincident linear polarimetry using stacked organic photovoltaics.
    Roy SG; Awartani OM; Sen P; O'Connor BT; Kudenov MW
    Opt Express; 2016 Jun; 24(13):14737-47. PubMed ID: 27410627
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Mueller matrix polarimetry with four photoelastic modulators: theory and calibration.
    Arteaga O; Freudenthal J; Wang B; Kahr B
    Appl Opt; 2012 Oct; 51(28):6805-17. PubMed ID: 23033096
    [TBL] [Abstract][Full Text] [Related]  

  • 45. 100 kHz Mueller polarimeter in reflection configuration.
    Le Gratiet A; Rivet S; Dubreuil M; Le Grand Y
    Opt Lett; 2015 Feb; 40(4):645-8. PubMed ID: 25680171
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Comprehensive characterization of a general composite waveplate by spectroscopic Mueller matrix polarimetry.
    Gu H; Chen X; Shi Y; Jiang H; Zhang C; Gong P; Liu S
    Opt Express; 2018 Sep; 26(19):25408-25425. PubMed ID: 30469643
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Structured decomposition design of partial Mueller matrix polarimeters.
    Alenin AS; Scott Tyo J
    J Opt Soc Am A Opt Image Sci Vis; 2015 Jul; 32(7):1302-12. PubMed ID: 26367159
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Birefringence effect studies of collagen formed by nonenzymatic glycation using dual-retarder Mueller polarimetry.
    Lien CH; Chen ZH; Phan QH
    J Biomed Opt; 2022 Aug; 27(8):087001. PubMed ID: 36452033
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Combined Stokes vector and Mueller matrix polarimetry for materials characterization.
    Hall SA; Hoyle MA; Post JS; Hore DK
    Anal Chem; 2013 Aug; 85(15):7613-9. PubMed ID: 23834365
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Comparative study of the imaging contrasts of Mueller matrix derived parameters between transmission and backscattering polarimetry.
    Liu T; Sun T; He H; Liu S; Dong Y; Wu J; Ma H
    Biomed Opt Express; 2018 Sep; 9(9):4413-4428. PubMed ID: 30615708
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Eigenvalue calibration method for 3 × 3 Mueller polarimeters.
    Qi J; Elson DS; Stoyanov D
    Opt Lett; 2019 May; 44(9):2362-2365. PubMed ID: 31042229
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Liquid crystal-based Mueller matrix spectral imaging polarimetry for parameterizing mineral structural organization.
    Gladish JC; Duncan DD
    Appl Opt; 2017 Jan; 56(3):626-635. PubMed ID: 28157922
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Mueller matrix imaging of prostate bulk tissues; Polarization parameters as a discriminating benchmark.
    Badieyan S; Ameri A; Razzaghi MR; Rafii-Tabar H; Sasanpour P
    Photodiagnosis Photodyn Ther; 2019 Jun; 26():90-96. PubMed ID: 30797118
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Compact complete imaging polarimeter using birefringent wedge prisms.
    Oka K; Kaneko T
    Opt Express; 2003 Jun; 11(13):1510-9. PubMed ID: 19466024
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Holistic and efficient calibration method for Mueller matrix imaging polarimeter with a high numerical aperture.
    Li Y; Li Y; Zhou G; Yan X; Ning T; Liu K; Liu L; Liu A; Ma Z
    Appl Opt; 2022 Nov; 61(33):9937-9945. PubMed ID: 36606825
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Spectral line polarimetry with a channeled polarimeter.
    van Harten G; Snik F; Rietjens JH; Martijn Smit J; Keller CU
    Appl Opt; 2014 Jul; 53(19):4187-94. PubMed ID: 25089978
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Alignment and temperature effects in liquid-crystal-based active polarimetry.
    Gladish JC; Duncan DD
    Appl Opt; 2014 Jun; 53(18):3982-92. PubMed ID: 24979431
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Mueller-matrix polarimeter using analysis of the nonlinear voltage-retardance relationship for liquid-crystal variable retarders.
    López-Téllez JM; Bruce NC
    Appl Opt; 2014 Aug; 53(24):5359-66. PubMed ID: 25321106
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Experimental limits for eigenvalue calibration in liquid-crystal Mueller-matrix polarimeters.
    Bruce NC; Rodríguez-Herrera OG; López-Téllez JM; Rodríguez-Nuñez O
    Opt Lett; 2018 Jun; 43(11):2712-2715. PubMed ID: 29856374
    [TBL] [Abstract][Full Text] [Related]  

  • 60. General and self-consistent method for the calibration of polarization modulators, polarimeters, and mueller-matrix ellipsometers.
    Compain E; Poirier S; Drevillon B
    Appl Opt; 1999 Jun; 38(16):3490-502. PubMed ID: 18319949
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.