BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

798 related articles for article (PubMed ID: 30630257)

  • 21. [Three-dimensional finite element analysis of influence of occlusal surface height on stress distribution around posterior implant-supported single crown].
    Zhao X; Zhang L; Sun J; Yang ZY; Xie QF
    Beijing Da Xue Xue Bao Yi Xue Ban; 2016 Feb; 48(1):94-100. PubMed ID: 26885916
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Three-dimensional modeling and finite element analysis in treatment planning for orthodontic tooth movement.
    Ammar HH; Ngan P; Crout RJ; Mucino VH; Mukdadi OM
    Am J Orthod Dentofacial Orthop; 2011 Jan; 139(1):e59-71. PubMed ID: 21195258
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Analysis of the effect of mesial implant position on surrounding bone stress of mandibular edentulous jaw under dynamic loads].
    Li Y; Sun C; Jia H; Luo XJ
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2017 Nov; 52(11):672-677. PubMed ID: 29972946
    [No Abstract]   [Full Text] [Related]  

  • 24. Mechanical behavior of dental implants in different positions in the rehabilitation of the anterior maxilla.
    Corrêa CB; Margonar R; Noritomi PY; Vaz LG
    J Prosthet Dent; 2014 Apr; 111(4):301-9. PubMed ID: 24355510
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Influence of implant length and diameter on stress distribution: a finite element analysis.
    Himmlová L; Dostálová T; Kácovský A; Konvicková S
    J Prosthet Dent; 2004 Jan; 91(1):20-5. PubMed ID: 14739889
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Biomechanical Comparison of Different Implant Inclinations and Cantilever Lengths in All-on-4 Treatment Concept by Three-Dimensional Finite Element Analysis.
    Ozan O; Kurtulmus-Yilmaz S
    Int J Oral Maxillofac Implants; 2018; 33(1):64-71. PubMed ID: 29340344
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Platform switching: biomechanical evaluation using three-dimensional finite element analysis.
    Tabata LF; Rocha EP; Barão VA; Assunção WG
    Int J Oral Maxillofac Implants; 2011; 26(3):482-91. PubMed ID: 21691594
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: three-dimensional finite element analysis.
    Kan B; Coskunses FM; Mutlu I; Ugur L; Meral DG
    Int J Oral Maxillofac Surg; 2015 Jul; 44(7):908-13. PubMed ID: 25818310
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparing the influence of crestal cortical bone and sinus floor cortical bone in posterior maxilla bi-cortical dental implantation: a three-dimensional finite element analysis.
    Yan X; Zhang X; Chi W; Ai H; Wu L
    Acta Odontol Scand; 2015 May; 73(4):312-20. PubMed ID: 25330164
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Two dental implants designed for immediate loading: a finite element analysis.
    Pierrisnard L; Hure G; Barquins M; Chappard D
    Int J Oral Maxillofac Implants; 2002; 17(3):353-62. PubMed ID: 12074450
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Three-dimensional finite element analysis of occlusal splint and implant connection on stress distribution in implant-supported fixed dental prosthesis and peri-implantal bone.
    Dos Santos Marsico V; Lehmann RB; de Assis Claro CA; Amaral M; Vitti RP; Neves ACC; da Silva Concilio LR
    Mater Sci Eng C Mater Biol Appl; 2017 Nov; 80():141-148. PubMed ID: 28866149
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Impact of dental and zygomatic implants on stress distribution in maxillary defects: a 3-dimensional finite element analysis study.
    Korkmaz FM; Korkmaz YT; Yaluğ S; Korkmaz T
    J Oral Implantol; 2012 Oct; 38(5):557-67. PubMed ID: 20925533
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A three-dimensional finite element analysis for overdenture attachments supported by teeth and/or mini dental implants.
    Fatalla AA; Song K; Du T; Cao Y
    J Prosthodont; 2012 Dec; 21(8):604-13. PubMed ID: 22845394
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The Effect Of Tapered And Cylindrical Implants On Stress Distribution In Different Bone Qualities: A Finite Element Analysis.
    Sivrikaya EC; Omezli MM
    Int J Oral Maxillofac Implants; 2019; 34(6):e99–e105. PubMed ID: 31184631
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants.
    Ding X; Liao SH; Zhu XH; Zhang XH; Zhang L
    Clin Implant Dent Relat Res; 2009 Dec; 11(4):279-87. PubMed ID: 18783411
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of stresses occurring on three different zirconia dental implants: three-dimensional finite element analysis.
    Caglar A; Bal BT; Aydin C; Yilmaz H; Ozkan S
    Int J Oral Maxillofac Implants; 2010; 25(1):95-103. PubMed ID: 20209191
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effects of implant diameter, insertion depth, and loading angle on stress/strain fields in implant/jawbone systems: finite element analysis.
    Qian L; Todo M; Matsushita Y; Koyano K
    Int J Oral Maxillofac Implants; 2009; 24(5):877-86. PubMed ID: 19865628
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Evaluation of optimal taper of immediately loaded wide-diameter implants: a finite element analysis.
    Atieh MA; Shahmiri RA
    J Oral Implantol; 2013 Apr; 39(2):123-32. PubMed ID: 21905902
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Stress and strain analysis of the bone-implant interface: a comparison of fiber-reinforced composite and titanium implants utilizing 3-dimensional finite element study.
    Shinya A; Ballo AM; Lassila LV; Shinya A; Närhi TO; Vallittu PK
    J Oral Implantol; 2011 Mar; 37 Spec No():133-40. PubMed ID: 20545537
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.
    Merıç G; Erkmen E; Kurt A; Eser A; özden AU
    Acta Odontol Scand; 2011 Nov; 69(6):374-84. PubMed ID: 21449688
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 40.