These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
1146 related articles for article (PubMed ID: 30630465)
1. Locking nail versus locking plate for proximal humeral fracture fixation in an elderly population: a prospective randomised controlled trial. Plath JE; Kerschbaum C; Seebauer T; Holz R; Henderson DJH; Förch S; Mayr E BMC Musculoskelet Disord; 2019 Jan; 20(1):20. PubMed ID: 30630465 [TBL] [Abstract][Full Text] [Related]
2. Operative treatment of 2-part surgical neck fractures of the proximal humerus (AO 11-A3) in the elderly: Cement augmented locking plate Philos™ vs. proximal humerus nail MultiLoc®. Helfen T; Siebenbürger G; Mayer M; Böcker W; Ockert B; Haasters F BMC Musculoskelet Disord; 2016 Oct; 17(1):448. PubMed ID: 27793135 [TBL] [Abstract][Full Text] [Related]
3. Locking intramedullary nails compared with locking plates for two- and three-part proximal humeral surgical neck fractures: a randomized controlled trial. Gracitelli ME; Malavolta EA; Assunção JH; Kojima KE; dos Reis PR; Silva JS; Ferreira Neto AA; Hernandez AJ J Shoulder Elbow Surg; 2016 May; 25(5):695-703. PubMed ID: 27085296 [TBL] [Abstract][Full Text] [Related]
4. Functional outcome and complications following PHILOS plate fixation in proximal humeral fractures. Geiger EV; Maier M; Kelm A; Wutzler S; Seebach C; Marzi I Acta Orthop Traumatol Turc; 2010; 44(1):1-6. PubMed ID: 20513984 [TBL] [Abstract][Full Text] [Related]
5. Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study. Südkamp N; Bayer J; Hepp P; Voigt C; Oestern H; Kääb M; Luo C; Plecko M; Wendt K; Köstler W; Konrad G J Bone Joint Surg Am; 2009 Jun; 91(6):1320-8. PubMed ID: 19487508 [TBL] [Abstract][Full Text] [Related]
6. Comparison of the Effects of Proximal Humeral Internal Locking System (PHILOS) Alone and PHILOS Combined with Fibular Allograft in the Treatment of Neer Three- or Four-part Proximal Humerus Fractures in the Elderly. Zhao L; Qi YM; Yang L; Wang GR; Zheng SN; Wang Q; Liang B; Jiang CZ Orthop Surg; 2019 Dec; 11(6):1003-1012. PubMed ID: 31762222 [TBL] [Abstract][Full Text] [Related]
7. Shoulder arthroscopy combined to hardware removal in proximal humeral fractures: a series of 58 cases with a mean follow-up of 2 years. Maroun C; Aliani D; Hass A; Werthel JD; Vidil A; Valenti P Eur J Orthop Surg Traumatol; 2017 Apr; 27(3):317-321. PubMed ID: 28289904 [TBL] [Abstract][Full Text] [Related]
8. Locking intramedullary nails and locking plates in the treatment of two-part proximal humeral surgical neck fractures: a prospective randomized trial with a minimum of three years of follow-up. Zhu Y; Lu Y; Shen J; Zhang J; Jiang C J Bone Joint Surg Am; 2011 Jan; 93(2):159-68. PubMed ID: 21248213 [TBL] [Abstract][Full Text] [Related]
9. Titanium mini locking plate with trans-osseous sutures for the treatment of humeral greater tuberosity fracture osteosynthesis versus PHILOS: a retrospective view. Xue G; Chahal K; Lim T; Hu S; Li S; Liu J Int Orthop; 2018 Oct; 42(10):2467-2473. PubMed ID: 29500554 [TBL] [Abstract][Full Text] [Related]
10. Preliminary clinical and radiographic outcomes of proximal humeral fractures: comparison of ALPS and PHILOS plating in Asian patients in Taiwan. Chen CY; Chang HW; Hsieh SL; Chang CC; Tsai CH; Chen YW; Lin TL; Hsu CJ J Orthop Surg Res; 2020 Aug; 15(1):364. PubMed ID: 32859221 [TBL] [Abstract][Full Text] [Related]
11. Outcomes of Reverse Total Shoulder Arthroplasty for Proximal Humeral Fractures: Primary Arthroplasty Versus Secondary Arthroplasty After Failed Proximal Humeral Locking Plate Fixation. Sebastia-Forcada E; Lizaur-Utrilla A; Cebrian-Gomez R; Miralles-Muñoz FA; Lopez-Prats FA J Orthop Trauma; 2017 Aug; 31(8):e236-e240. PubMed ID: 28430721 [TBL] [Abstract][Full Text] [Related]
12. Minimally invasive percutaneous plating of proximal humeral shaft fractures with the Proximal Humerus Internal Locking System (PHILOS). Brunner A; Thormann S; Babst R J Shoulder Elbow Surg; 2012 Aug; 21(8):1056-63. PubMed ID: 21872493 [TBL] [Abstract][Full Text] [Related]
13. Fractures and fracture-dislocations of the proximal humerus: A retrospective analysis of 82 cases treated with the Philos(®) locking plate. Erasmo R; Guerra G; Guerra L Injury; 2014 Dec; 45 Suppl 6():S43-8. PubMed ID: 25457318 [TBL] [Abstract][Full Text] [Related]
15. A comparative study of locking plate combined with minimally invasive plate osteosynthesis and intramedullary nail fixation in the treatment of Neer classification of two-part and three-part fractures of the proximal humerus. Zhu X; Ding C; Zhu Y; Nian S; Tang H Eur J Orthop Surg Traumatol; 2024 Jul; 34(5):2743-2749. PubMed ID: 38761200 [TBL] [Abstract][Full Text] [Related]
16. Fixation of 4-part fractures of the proximal humerus: Can we identify radiological criteria that support locking plates or IM nailing? Comparative, retrospective study of 107 cases. Gadea F; Favard L; Boileau P; Cuny C; d'Ollone T; Saragaglia D; Sirveaux F; Orthop Traumatol Surg Res; 2016 Dec; 102(8):963-970. PubMed ID: 27818186 [TBL] [Abstract][Full Text] [Related]
18. [The results of internal fixation of proximal humeral fractures with the PHILOS locking plate]. Korkmaz MF; Aksu N; Göğüş A; Debre M; Kara AN; Işiklar ZU Acta Orthop Traumatol Turc; 2008; 42(2):97-105. PubMed ID: 18552530 [TBL] [Abstract][Full Text] [Related]
19. Screw-tip augmentation versus standard locked plating of displaced proximal humeral fractures: a retrospective comparative cohort study. Siebenbürger G; Helfen T; Biermann N; Haasters F; Böcker W; Ockert B J Shoulder Elbow Surg; 2019 Jul; 28(7):1326-1333. PubMed ID: 31056395 [TBL] [Abstract][Full Text] [Related]
20. [Effectiveness analysis of proximal humerus internal locking system plate combined with rotator cuff reinforcement suture in treatment of Neer type Ⅳ proximal humerus fracture]. Ma J; Ni Y; Chen M; Zhang W; Xu H; Wang Y Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2022 Dec; 36(12):1465-1470. PubMed ID: 36545853 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]