These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 30636683)

  • 1. Simple "flip-n-flex" technique facilitates coaxial SAPIEN 3 valve alignment in right transaxillary transcatheter aortic valve replacement.
    Zhan Y; Kawabori M; Lofftus S; Weintraub A
    EuroIntervention; 2019 Jul; 15(4):e340-e341. PubMed ID: 30636683
    [No Abstract]   [Full Text] [Related]  

  • 2. Transcarotid Transcatheter Aortic Valve Replacement With Simple "Flip-n-Flex" Technique.
    McGrath D; Salehi P; Weintraub A; Kawabori M; Irshad A; Ayoob F; Resor C; Chen FY; Zhan Y
    Ann Thorac Surg; 2022 Dec; 114(6):e475-e477. PubMed ID: 35346628
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Right transaxillary transcatheter aortic valve replacement is comparable to left despite challenges.
    McGrath D; Lee H; Sun C; Kawabori M; Zhan Y
    Gen Thorac Cardiovasc Surg; 2024 Mar; ():. PubMed ID: 38460099
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Successful use of 20mm SAPIEN 3 for valve-in-valve intervention within a 19 mm degenerated aortic bioprosthetic valve.
    Thukkani AK; Klein MR; Mauney M; Kouchoukos N; Baker JN
    Int J Cardiol; 2016 Jan; 203():156-7. PubMed ID: 26512831
    [No Abstract]   [Full Text] [Related]  

  • 5. Stuck Leaflet After Transcatheter Aortic Valve Replacement With a SAPIEN-3 Valve: New Valve, Old Complication.
    Couture EL; Labbé BM; DeLarochellière R; Rodés-Cabau J; Paradis JM
    JACC Cardiovasc Interv; 2016 Jul; 9(14):e133-5. PubMed ID: 27372196
    [No Abstract]   [Full Text] [Related]  

  • 6. Evaluation of the Edwards SAPIEN 3 Transcatheter Valve For Aortic Stenosis.
    Htun NM; Webb JG
    Expert Rev Med Devices; 2016; 13(3):225-32. PubMed ID: 26878548
    [TBL] [Abstract][Full Text] [Related]  

  • 7. First-in-human transcatheter aortic valve-in-valve replacement with the SAPIEN 3 heart valve.
    Mancio J; Almeida C; Pires-Morais G; Ferreira W; Carvalho M; Rodrigues A; Santos L; Melica B; Oliveira M; Braga P; Ribeiro VG
    Int J Cardiol; 2015 Dec; 201():260-1. PubMed ID: 26301652
    [No Abstract]   [Full Text] [Related]  

  • 8. Safety and efficacy of the percutaneous transaxillary access for transcatheter aortic valve implantation using various transcatheter heart valves in 100 consecutive patients.
    Schäfer U; Deuschl F; Schofer N; Frerker C; Schmidt T; Kuck KH; Kreidel F; Schirmer J; Mizote I; Reichenspurner H; Blankenberg S; Treede H; Conradi L
    Int J Cardiol; 2017 Apr; 232():247-254. PubMed ID: 28118931
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Valve-in-valve TAVR using the SAPIEN 3 transcatheter heart valve: still plagued by patient-prosthesis mismatch.
    Saxon JT; Cohen DJ; Feldman T
    EuroIntervention; 2018 Jul; 14(4):e377-e379. PubMed ID: 30028300
    [No Abstract]   [Full Text] [Related]  

  • 10. Outcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure.
    Barbanti M; Webb JG; Tamburino C; Van Mieghem NM; Makkar RR; Piazza N; Latib A; Sinning JM; Won-Keun K; Bleiziffer S; Bedogni F; Kapadia S; Tchetche D; Rodés-Cabau J; Fiorina C; Nombela-Franco L; De Marco F; de Jaegere PP; Chakravarty T; Vaquerizo B; Colombo A; Svensson L; Lange R; Nickenig G; Möllmann H; Walther T; Della Rosa F; Elhmidi Y; Dvir D; Brambilla N; Immè S; Sgroi C; Gulino S; Todaro D; Pilato G; Petronio AS; Tamburino C
    Circ Cardiovasc Interv; 2016 Sep; 9(9):. PubMed ID: 27578840
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement With the SAPIEN 3.
    Mauri V; Reimann A; Stern D; Scherner M; Kuhn E; Rudolph V; Rosenkranz S; Eghbalzadeh K; Friedrichs K; Wahlers T; Baldus S; Madershahian N; Rudolph TK
    JACC Cardiovasc Interv; 2016 Nov; 9(21):2200-2209. PubMed ID: 27832845
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Self-expanding Portico Valve Versus Balloon-expandable SAPIEN XT Valve in Patients With Small Aortic Annuli: Comparison of Hemodynamic Performance.
    Del Trigo M; Dahou A; Webb JG; Dvir D; Puri R; Abdul-Jawad Altisent O; Campelo-Parada F; Thompson C; Leipsic J; Stub D; DeLarochellière R; Paradis JM; Dumont E; Doyle D; Mohammadi S; Pasian S; Côté M; Pibarot P; Rodés-Cabau J
    Rev Esp Cardiol (Engl Ed); 2016 May; 69(5):501-8. PubMed ID: 26739827
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Plug-based closure in completely percutaneous right-sided transaxillary transcatheter aortic valve implantation.
    Kroon HG; De Jaegere P; Van Mieghem NM
    EuroIntervention; 2019 May; 15(1):76-77. PubMed ID: 30295294
    [No Abstract]   [Full Text] [Related]  

  • 14. Repeat transcatheter aortic valve replacement using a 23 mm Evolut R in a small patient with a failed 20 mm SAPIEN XT.
    Saji M; Tobaru T; Higuchi R; Takanashi S; Takayama M; Isobe M
    Cardiovasc Interv Ther; 2019 Jan; 34(1):80-82. PubMed ID: 29582354
    [No Abstract]   [Full Text] [Related]  

  • 15. The 3 S's of the Sapien balloon expandable valve.
    Kornowski R
    Catheter Cardiovasc Interv; 2016 Sep; 88(3):476-8. PubMed ID: 27619748
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transcatheter aortic valve implantation with a Sapien 3 Commander 20 mm valves in patients with degenerated 19 mm bioprosthetic aortic valve.
    Loyalka P; Nascimbene A; Schechter M; Petrovic M; Sundara Raman A; Gregoric ID; Kar B
    Catheter Cardiovasc Interv; 2017 Jun; 89(7):1280-1285. PubMed ID: 27696659
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fracture of the delivery balloon shaft during balloon-expandable prosthesis alignment during implantation of an Edwards SAPIEN 3.
    Arai T; Hovasse T; Chevalier B
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):997-999. PubMed ID: 27142180
    [TBL] [Abstract][Full Text] [Related]  

  • 18. How should I treat an Edwards SAPIEN 3 aortic valve embolisation during a transaortic transcatheter aortic valve implantation?
    Fournier S; Monney P; Roguelov C; Ferrari E; Eeckhout E; Muller O; Durko A; Van Mieghem NM; Kappetein AP; Margey R
    EuroIntervention; 2017 Jul; 13(4):495-498. PubMed ID: 28735254
    [No Abstract]   [Full Text] [Related]  

  • 19. Computed Tomography-Based Oversizing Degrees and Incidence of Paravalvular Regurgitation of a New Generation Transcatheter Heart Valve.
    Blanke P; Pibarot P; Hahn R; Weissman N; Kodali S; Thourani V; Parvataneni R; Dvir D; Naoum C; Nørgaard BL; Douglas P; Jaber W; Khalique OK; Jilaihawi H; Mack M; Smith C; Leon M; Webb J; Leipsic J
    JACC Cardiovasc Interv; 2017 Apr; 10(8):810-820. PubMed ID: 28427598
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Minimally Invasive SAPIEN in Mitral Annular Calcification Following Transcatheter Aortic Valve Replacement: Feasibility and Lessons Learned.
    Nguyen TC; Umana-Pizano JB; Landinez GP; Balan P
    Semin Thorac Cardiovasc Surg; 2018; 30(3):290-292. PubMed ID: 29626508
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.