BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 30654352)

  • 1. Pulmonary blood mass dynamics on 4DCT during tidal breathing.
    Myziuk N; Guerrero T; Sakthivel G; Solis D; Nair G; Guerra R; Castillo E
    Phys Med Biol; 2019 Feb; 64(4):045014. PubMed ID: 30654352
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of planned dose on different CT image sets to four-dimensional Monte Carlo dose recalculation using the patient's actual breathing trace for lung stereotactic body radiation therapy.
    Freislederer P; von Münchow A; Kamp F; Heinz C; Gerum S; Corradini S; Söhn M; Reiner M; Roeder F; Floca R; Alber M; Belka C; Parodi K
    Med Phys; 2019 Jul; 46(7):3268-3277. PubMed ID: 31074510
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of irregular breathing patterns on internal target volumes in four-dimensional CT and cone-beam CT images in the context of stereotactic lung radiotherapy.
    Clements N; Kron T; Franich R; Dunn L; Roxby P; Aarons Y; Chesson B; Siva S; Duplan D; Ball D
    Med Phys; 2013 Feb; 40(2):021904. PubMed ID: 23387752
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simulation of dosimetry impact of 4DCT uncertainty in 4D dose calculation for lung SBRT.
    Liu G; Hu F; Ding X; Li X; Shao Q; Wang Y; Yang J; Quan H
    Radiat Oncol; 2019 Jan; 14(1):1. PubMed ID: 30621744
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Markerless tracking of small lung tumors for stereotactic radiotherapy.
    van Sörnsen de Koste JR; Dahele M; Mostafavi H; Sloutsky A; Senan S; Slotman BJ; Verbakel WF
    Med Phys; 2015 Apr; 42(4):1640-52. PubMed ID: 25832054
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Estimating lung ventilation directly from 4D CT Hounsfield unit values.
    Kipritidis J; Hofman MS; Siva S; Callahan J; Le Roux PY; Woodruff HC; Counter WB; Keall PJ
    Med Phys; 2016 Jan; 43(1):33. PubMed ID: 26745897
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Radiation-induced Hounsfield unit change correlates with dynamic CT perfusion better than 4DCT-based ventilation measures in a novel-swine model.
    Wuschner AE; Wallat EM; Flakus MJ; Shanmuganayagam D; Meudt J; Christensen GE; Reinhardt JM; Miller JR; Lawless MJ; Baschnagel AM; Bayouth JE
    Sci Rep; 2021 Jun; 11(1):13156. PubMed ID: 34162987
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Variation in Lung Tumour Breathing Motion between Planning Four-dimensional Computed Tomography and Stereotactic Ablative Radiotherapy Delivery and its Dosimetric Implications: Any Role for Four-dimensional Set-up Verification?
    Ruben JD; Seeley A; Panettieri V; Ackerly T
    Clin Oncol (R Coll Radiol); 2016 Jan; 28(1):21-7. PubMed ID: 26432188
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 3D delivered dose assessment using a 4DCT-based motion model.
    Cai W; Hurwitz MH; Williams CL; Dhou S; Berbeco RI; Seco J; Mishra P; Lewis JH
    Med Phys; 2015 Jun; 42(6):2897-907. PubMed ID: 26127043
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dynamic volume vs respiratory correlated 4DCT for motion assessment in radiation therapy simulation.
    Coolens C; Bracken J; Driscoll B; Hope A; Jaffray D
    Med Phys; 2012 May; 39(5):2669-81. PubMed ID: 22559637
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of fractional regional ventilation using 4D-CT and effects of breathing maneuvers on ventilation.
    Mistry NN; Diwanji T; Shi X; Pokharel S; Feigenberg S; Scharf SM; D'Souza WD
    Int J Radiat Oncol Biol Phys; 2013 Nov; 87(4):825-31. PubMed ID: 24064319
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Novel Respiratory Motion Perturbation Model Adaptable to Patient Breathing Irregularities.
    Yuan A; Wei J; Gaebler CP; Huang H; Olek D; Li G
    Int J Radiat Oncol Biol Phys; 2016 Dec; 96(5):1087-1096. PubMed ID: 27745981
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quantitative early decision making metric for identifying irregular breathing in 4DCT.
    Kiely JP; Olszanski A; Both S; Low DA; White BM
    Med Phys; 2015 Oct; 42(10):5654-60. PubMed ID: 26429239
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Distribution of lung tissue hysteresis during free breathing.
    White B; Zhao T; Lamb J; Wuenschel S; Bradley J; El Naqa I; Low D
    Med Phys; 2013 Apr; 40(4):043501. PubMed ID: 23556925
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements.
    Du K; Reinhardt JM; Christensen GE; Ding K; Bayouth JE
    Med Phys; 2013 Dec; 40(12):123504. PubMed ID: 24320544
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Physiologically guided approach to characterizing respiratory motion.
    White BM; Zhao T; Lamb JM; Bradley JD; Low DA
    Med Phys; 2013 Dec; 40(12):121723. PubMed ID: 24320509
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On the validity of density overrides for VMAT lung SBRT planning.
    Wiant D; Vanderstraeten C; Maurer J; Pursley J; Terrell J; Sintay BJ
    Med Phys; 2014 Aug; 41(8):081707. PubMed ID: 25086517
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The use of 4DCT to reduce lung dose: a dosimetric analysis.
    Khan F; Bell G; Antony J; Palmer M; Balter P; Bucci K; Chapman MJ
    Med Dosim; 2009; 34(4):273-8. PubMed ID: 19854385
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessment of regional ventilation and deformation using 4D-CT imaging for healthy human lungs during tidal breathing.
    Jahani N; Choi S; Choi J; Iyer K; Hoffman EA; Lin CL
    J Appl Physiol (1985); 2015 Nov; 119(10):1064-74. PubMed ID: 26316512
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Utility of four-dimensional computed tomography for analysis of intrafractional and interfractional variation in lung volumes.
    Rosen B; Starkschall G; Britton K; Mohan R; Cox JD
    Int J Radiat Oncol Biol Phys; 2008 Sep; 72(1):288-94. PubMed ID: 18722279
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.