BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 30660490)

  • 1. Improved expansion of T cells in culture when isolated with an equipment-free, high-throughput, flow-through microfluidic module versus traditional density gradient centrifugation.
    Strachan BC; Xia H; Vörös E; Gifford SC; Shevkoplyas SS
    Cytotherapy; 2019 Feb; 21(2):234-245. PubMed ID: 30660490
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A high-throughput microfluidic device based on controlled incremental filtration to enable centrifugation-free, low extracorporeal volume leukapheresis.
    Lezzar DL; Lam FW; Huerta R; Mukhamedshin A; Lu M; Shevkoplyas SS
    Sci Rep; 2022 Aug; 12(1):13798. PubMed ID: 35963876
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pinched flow coupled shear-modulated inertial microfluidics for high-throughput rare blood cell separation.
    Bhagat AA; Hou HW; Li LD; Lim CT; Han J
    Lab Chip; 2011 Jun; 11(11):1870-8. PubMed ID: 21505682
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Red blood cell rosetting enables size-based separation of specific lymphocyte subsets from blood in a microfluidic device.
    Abhishek K; Louis Sam Titus ASC; Dinh MTP; Mukhamedshin A; Mohan C; Gifford SC; Shevkoplyas SS
    Lab Chip; 2023 Mar; 23(7):1804-1815. PubMed ID: 36723024
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Low-stress Microfluidic Density-gradient Centrifugation for Blood Cell Sorting.
    Sun Y; Sethu P
    Biomed Microdevices; 2018 Aug; 20(3):77. PubMed ID: 30155743
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Purification of Lymphocytes by Acoustic Separation in Plastic Microchannels.
    Lissandrello C; Dubay R; Kotz KT; Fiering J
    SLAS Technol; 2018 Aug; 23(4):352-363. PubMed ID: 29346013
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rapid, label-free enrichment of lymphocytes in a closed system using a flow-through microfluidic device.
    Mukhamedshin A; Reddington RC; Dinh MTP; Abhishek K; Iqbal M; Manheim M; Gifford SC; Shevkoplyas SS
    Bioeng Transl Med; 2024 Jan; 9(1):e10602. PubMed ID: 38193116
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Isolation of Human Peripheral Blood T-Lymphocytes.
    Kizhakeyil A; Ong ST; Fazil MHUT; Chalasani MLS; Prasannan P; Verma NK
    Methods Mol Biol; 2019; 1930():11-17. PubMed ID: 30610593
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rapid and Safe Isolation of Human Peripheral Blood B and T Lymphocytes through Spiral Microfluidic Channels.
    Chiu PL; Chang CH; Lin YL; Tsou PH; Li BR
    Sci Rep; 2019 May; 9(1):8145. PubMed ID: 31148602
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Separation of in-vitro-derived megakaryocytes and platelets using spinning-membrane filtration.
    Schlinker AC; Radwanski K; Wegener C; Min K; Miller WM
    Biotechnol Bioeng; 2015 Apr; 112(4):788-800. PubMed ID: 25312394
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparative analysis of platelet isolation techniques for the in vivo study of the microcirculation.
    Vollmar B; Slotta JE; Nickels RM; Wenzel E; Menger MD
    Microcirculation; 2003 Apr; 10(2):143-52. PubMed ID: 12700583
    [TBL] [Abstract][Full Text] [Related]  

  • 12. GMP-manufactured density gradient media for optimized mesenchymal stromal/stem cell isolation and expansion.
    Grisendi G; Annerén C; Cafarelli L; Sternieri R; Veronesi E; Cervo GL; Luminari S; Maur M; Frassoldati A; Palazzi G; Otsuru S; Bambi F; Paolucci P; Pierfranco C; Horwitz E; Dominici M
    Cytotherapy; 2010 Jul; 12(4):466-77. PubMed ID: 20353309
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Continuous scalable blood filtration device using inertial microfluidics.
    Mach AJ; Di Carlo D
    Biotechnol Bioeng; 2010 Oct; 107(2):302-11. PubMed ID: 20589838
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A rapid method to isolate platelets from human blood by density gradient centrifugation.
    Hoffman M; Monroe DM; Roberts HR
    Am J Clin Pathol; 1992 Nov; 98(5):531-3. PubMed ID: 1485606
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Recent advances in microfluidic cell separation to enable centrifugation-free, low extracorporeal volume leukapheresis in pediatric patients.
    Iqbal M; Mukhamedshin A; Lezzar DL; Abhishek K; McLennan AL; Lam FW; Shevkoplyas SS
    Blood Transfus; 2023 Nov; 21(6):494-513. PubMed ID: 37146298
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ficoll-Paque versus Lymphoprep: a comparative study of two density gradient media for therapeutic bone marrow mononuclear cell preparations.
    Yeo C; Saunders N; Locca D; Flett A; Preston M; Brookman P; Davy B; Mathur A; Agrawal S
    Regen Med; 2009 Sep; 4(5):689-96. PubMed ID: 19761394
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Microfluidic Immiscible Phase Filtration System for the Isolation of Small Numbers of Cells from Whole Blood.
    Pirozzi I; Snider A; Kraus M; Schönbrunner ER; Tripathi A
    Cytometry A; 2019 Aug; 95(8):885-897. PubMed ID: 30852843
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Separation of human lymphocytes from citrated blood by density gradient (NycoPrep) centrifugation: monocyte depletion depending upon activation of membrane potassium channels.
    Bøyum A; Brincker Fjerdingstad H; Martinsen I; Lea T; Løvhaug D
    Scand J Immunol; 2002 Jul; 56(1):76-84. PubMed ID: 12100474
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Isolation and subfractionation of human peripheral blood mononuclear cells (PBMC) by density gradient centrifugation on Percoll.
    Ulmer AJ; Scholz W; Ernst M; Brandt E; Flad HD
    Immunobiology; 1984 May; 166(3):238-50. PubMed ID: 6329947
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Removal of T and B lymphocytes by in-line filtration: evaluation of the efficiency of a polyester filter type (Pall WBF-2) by flow cytometric counting.
    Guber SE; Neumüller J; Schwartz DW; Köhler M; Mayr WR
    Vox Sang; 2002 Oct; 83(3):234-8. PubMed ID: 12366765
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.