  • 21. Successful transapical implantation of an Edwards Sapien valve within an insufficient aortic CoreValve prosthesis: an initial experience.
    Schleger S; Kasel M; Vogel J; Lieber M; Antoni D; Hoffmann E; Eichinger WB
    Ann Thorac Surg; 2013 Mar; 95(3):1070-2. PubMed ID: 23438533
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Aortic bioprosthetic valve deterioration 8 months after implantation.
    Wiedemann D; Bonaros N; Laufer G; Kocher A
    Ann Thorac Surg; 2010 Jan; 89(1):277-9. PubMed ID: 20103255
    [TBL] [Abstract][Full Text] [Related]  

  • 23. St. Jude Medical Trifecta aortic valve: results from a prospective regional multicentre registry.
    Mariscalco G; Mariani S; Bichi S; Biondi A; Blasio A; Borsani P; Corti F; De Chiara B; Gherli R; Leva C; Russo CF; Tasca G; Vanelli P; Alfieri O; Antona C; Di Credico G; Esposito G; Gamba A; Martinelli L; Menicanti L; Paolini G; Beghi C
    J Cardiothorac Surg; 2015 Nov; 10():169. PubMed ID: 26589286
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Early structural valve deterioration of a Trifecta bioprosthesis: a minimally invasive redo approach.
    Gavalaki A; Roussakis A; Perreas K
    Eur J Cardiothorac Surg; 2020 Jun; 57(6):1228. PubMed ID: 31746989
    [No Abstract]   [Full Text] [Related]  

  • 25. Near Catastrophic Accelerated Structural Degeneration of the Perimount Magna Pericardial Bioprosthesis in Children.
    Philip R; Kumar TK; Waller BR; McCoy M; Knott-Craig CJ
    Ann Thorac Surg; 2016 Jul; 102(1):308-11. PubMed ID: 27343502
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Redo Aortic Valve Replacement Following Bio-Bentall's Procedure.
    Liu C; Doig F; Naidoo R; Tesar P
    Heart Lung Circ; 2019 Oct; 28(10):e131-e133. PubMed ID: 31175018
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Early structural valve deterioration of the Trifecta aortic valve biological prosthesis: a word of caution.
    Saxena P; Greason KL; Schaff HV
    J Thorac Cardiovasc Surg; 2014 Jan; 147(1):e10-1. PubMed ID: 24041765
    [No Abstract]   [Full Text] [Related]  

  • 28. Reoperation on stentless aortic xenografts.
    Luciani GB; Bertolini P; Vecchi B; Mazzucco A
    Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S104-9. PubMed ID: 9930427
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Is timing everything? Bioprosthetic valve fracture in valve-in-valve TAVR.
    Jones TL; Sharma V; Glotzbach JP; Welt FGP; Tandar A
    J Card Surg; 2020 Nov; 35(11):3242-3243. PubMed ID: 32840902
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Aortic regurgitation due to perforation of the right coronary cusp 10 years after implantation of a freestyle stentless bioprosthesis.
    Okamoto Y; Katsu M; Matsumoto M
    J Card Surg; 2011 Nov; 26(6):613-4. PubMed ID: 21951139
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Percutaneous Closure of a Large Paravalvular Prosthetic Aortic Leak.
    Broncano J; Suárez de Lezo J; Suárez de Lezo J
    Rev Esp Cardiol (Engl Ed); 2019 Oct; 72(10):863. PubMed ID: 30287241
    [No Abstract]   [Full Text] [Related]  

  • 32. Trifecta Aortic Bioprosthesis: Midterm Results in 1,953 Patients From a Single Center.
    Kilic A; Sultan I; Navid F; Aranda-Michel E; Chu D; Thoma F; Gleason TG
    Ann Thorac Surg; 2019 May; 107(5):1356-1362. PubMed ID: 30513317
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Pannus-related prosthetic valve dysfunction and life-threatening aortic regurgitation.
    Mullenix PS; Parsa CJ; Mackensen GB; Jollis JG; Harrison JK; Hughes GC
    J Heart Valve Dis; 2008 Nov; 17(6):666-9. PubMed ID: 19137799
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Trifecta Bioprosthesis Sudden-Onset Three-Leaflet Detachment.
    Reyes G; Monguio E; Gomez-Marino M; Gomez-Tello V; Cortina J
    Ann Thorac Surg; 2021 Feb; 111(2):e127-e128. PubMed ID: 32619616
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Is Commissural region tear an Achilles' heel of the Trifecta aortic bioprosthesis?
    Chengalath MM; Ranganathan B; Periappuram JC
    Asian Cardiovasc Thorac Ann; 2018 Jan; 26(1):67. PubMed ID: 29181990
    [No Abstract]   [Full Text] [Related]  

  • 36. Early Structural Valve Degeneration of Trifecta Bioprosthesis.
    Fukuhara S; Shiomi S; Yang B; Kim K; Bolling SF; Haft J; Tang P; Pagani F; Prager RL; Chetcuti S; Grossman PM; Patel HJ; Deeb GM
    Ann Thorac Surg; 2020 Mar; 109(3):720-727. PubMed ID: 31398357
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Excellent Hemodynamic Performance After Aortic Valve Neocuspidization Using Autologous Pericardium.
    Krane M; Boehm J; Prinzing A; Ziegelmueller J; Holfeld J; Lange R
    Ann Thorac Surg; 2021 Jan; 111(1):126-133. PubMed ID: 32540439
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Challenging transfemoral valve-in-valve implantation in a degenerated stentless bioprosthetic aortic valve.
    Halapas A; Chrissoheris M; Spargias K
    J Invasive Cardiol; 2014 Aug; 26(8):E106-8. PubMed ID: 25091103
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Severe Prosthetic Mitral Stenosis Misinterpreted as Severe Aortic Regurgitation.
    Geube M; Knight J; Sale S
    J Cardiothorac Vasc Anesth; 2019 Jul; 33(7):2079-2082. PubMed ID: 30442518
    [No Abstract]   [Full Text] [Related]  

  • 40. Transcatheter Aortic Valve Replacement for Perceval Sutureless Aortic Valve Failure.
    Kalra A; Reyes M; Yang EY; Little SH; Nabi F; Barker CM; Ramchandani M; Reul RM; Reardon MJ; Kleiman NS
    J Invasive Cardiol; 2017 Jun; 29(6):E65-E66. PubMed ID: 28570238
    [TBL] [Abstract][Full Text] [Related]  