These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Unattended compared to traditional blood pressure measurement in patients with rheumatoid arthritis: a randomised cross-over study. Bartoloni E; Angeli F; Marcucci E; Perricone C; Cafaro G; Riccini C; Spighi L; Gildoni B; Cavallini C; Verdecchia P; Gerli R Ann Med; 2021 Dec; 53(1):2050-2059. PubMed ID: 34751628 [TBL] [Abstract][Full Text] [Related]
3. Relationship between arterial stiffness and unattended or attended blood pressure values. Paini A; Aggiusti C; Bertacchini F; Stassaldi D; Capellini S; de Ciuceis C; Sacca' G; Verzeri L; Gatta R; Rosei EA; Muiesan ML; Salvetti M J Hypertens; 2020 Feb; 38(2):243-248. PubMed ID: 31917375 [TBL] [Abstract][Full Text] [Related]
4. Unattended Automated Office Blood Pressure Measurement and Cardiac Target Organ Damage, A Pilot Study. Palomba C; Donadio S; Canciello G; Losi MA; Izzo R; Manzi MV; De Pisapia F; Mancusi C; De Luca N High Blood Press Cardiovasc Prev; 2019 Oct; 26(5):383-389. PubMed ID: 31444783 [TBL] [Abstract][Full Text] [Related]
5. Attended Versus Unattended Blood Pressure Measurement in a Real Life Setting. Bauer F; Seibert FS; Rohn B; Bauer KAR; Rolshoven E; Babel N; Westhoff TH Hypertension; 2018 Feb; 71(2):243-249. PubMed ID: 29255074 [TBL] [Abstract][Full Text] [Related]
6. Are Unattended Blood Pressure Measurements Necessary in All Patients Visiting an Outpatient Cardiology Clinic? Triantafyllidi H; Voutsinos D; Sioula K; Schoinas A; Benas D; Birmpa D; Ikonomidis I High Blood Press Cardiovasc Prev; 2020 Oct; 27(5):389-397. PubMed ID: 32720295 [TBL] [Abstract][Full Text] [Related]
7. Comparison of three office blood pressure measurement techniques and their effect on hypertension prevalence in the general population. Wohlfahrt P; Cífková R; Krajčoviechová A; Šulc P; Bruthans J; Linhart A; Filipovský J; Mayer O; Widimský J J Hypertens; 2020 Apr; 38(4):656-662. PubMed ID: 31834128 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of Unattended Automated Office, Conventional Office and Ambulatory Blood Pressure Measurements and Their Correlation with Target Organ Damage in an Outpatient Population of Hypertensives: Study Design and Methodological Aspects. Mancusi C; Saladini F; Pucci G; Bertacchini F; Bisogni V; Bruno RM; Rivasi G; Maloberti A; Manzi MV; Rosticci M; Monticone S; de Feo M; Del Pinto R; Geraci G; Canciello G; Pengo M; Parati G; High Blood Press Cardiovasc Prev; 2019 Dec; 26(6):493-499. PubMed ID: 31625119 [TBL] [Abstract][Full Text] [Related]
9. Unattended automatic blood pressure measurements vs conventional office readings in predicting hypertension-mediated organ damage. Stopa M; Zięba K; Tofilska A; Bilo G; Rajzer M; Olszanecka A Pol Arch Intern Med; 2024 May; 134(5):. PubMed ID: 38501381 [TBL] [Abstract][Full Text] [Related]
10. Unattended versus Attended Blood Pressure Measurement: Relationship with Retinal Microcirculation. Paini A; Agabiti Rosei C; De Ciuceis C; Aggiusti C; Bertacchini F; Cacciatore M; Capellini S; Gatta R; Malerba P; Stassaldi D; Rizzoni D; Salvetti M; Muiesan ML J Clin Med; 2022 Nov; 11(23):. PubMed ID: 36498540 [TBL] [Abstract][Full Text] [Related]
11. Attended Versus Unattended Automated Office Blood Pressure: A Systematic Review and Meta-analysis. Andreadis EA; Thomopoulos C; Geladari CV; Papademetriou V High Blood Press Cardiovasc Prev; 2019 Aug; 26(4):293-303. PubMed ID: 31290085 [TBL] [Abstract][Full Text] [Related]
12. Attended vs unattended systolic blood pressure measurement: A randomized comparison in patients with cardiovascular disease. Keeley EC; Villanueva M; Chen YE; Gong Y; Handberg EM; Smith SM; Pepine CJ; Cooper-DeHoff RM J Clin Hypertens (Greenwich); 2020 Nov; 22(11):1987-1992. PubMed ID: 32951360 [TBL] [Abstract][Full Text] [Related]
13. A multicentre study on unattended automated office blood pressure measurement in treated hypertensive patients. Filipovský J; Seidlerová J; Ceral J; Vysočanová P; Špác J; Souček M; Řiháček I; Mateřánková M; König P; Rosolová H Blood Press; 2018 Aug; 27(4):188-193. PubMed ID: 29334262 [TBL] [Abstract][Full Text] [Related]
14. Automated office blood pressure measurement by elderly patients in the waiting room. Toba A; Ishikawa J; Suzuki A; Harada K Blood Press Monit; 2021 Oct; 26(5):321-327. PubMed ID: 33741773 [TBL] [Abstract][Full Text] [Related]
15. Automated Office Blood Pressure and the Impact of Attendance and Rest on Diagnostic Accuracy. Green BB; Anderson ML; Cook AJ; Ehrlich K; Hall YN; Margolis KL; Thompson MJ Am J Hypertens; 2022 Jul; 35(7):638-646. PubMed ID: 35240678 [TBL] [Abstract][Full Text] [Related]
16. Attended and Unattended Automated Office Blood Pressure Measurements Have Better Agreement With Ambulatory Monitoring Than Conventional Office Readings. Andreadis EA; Geladari CV; Angelopoulos ET; Savva FS; Georgantoni AI; Papademetriou V J Am Heart Assoc; 2018 Apr; 7(8):. PubMed ID: 29627767 [TBL] [Abstract][Full Text] [Related]
17. Nurse-recorded clinic and ambulatory blood pressures correlate equally well with left ventricular mass and carotid intima-media thickness. Nyström F; Malmqvist K; Lind L; Kahan T J Intern Med; 2005 Jun; 257(6):514-22. PubMed ID: 15910555 [TBL] [Abstract][Full Text] [Related]
18. Unattended versus attended automated office blood pressure: Systematic review and meta-analysis of studies using the same methodology for both methods. Kollias A; Stambolliu E; Kyriakoulis KG; Gravvani A; Stergiou GS J Clin Hypertens (Greenwich); 2019 Feb; 21(2):148-155. PubMed ID: 30585383 [TBL] [Abstract][Full Text] [Related]
19. The independent relationship of epicardial adipose tissue with carotid intima-media thickness and endothelial functions: the association of pulse wave velocity with the active facilitated arterial conduction concept. Kocaman SA; Durakoğlugil ME; Çetin M; Erdoğan T; Ergül E; Çanga A Blood Press Monit; 2013 Apr; 18(2):85-93. PubMed ID: 23388404 [TBL] [Abstract][Full Text] [Related]
20. The Impact of Measurement Methods on Office Blood Pressure and Management of Hypertension in General Practice. Höller J; Villagomez Fuentes LE; Matthias K; Kreutz R High Blood Press Cardiovasc Prev; 2019 Dec; 26(6):483-491. PubMed ID: 31705461 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]