BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 30686649)

  • 1. Impact of frit dispersion on gradient performance in high-throughput liquid chromatography.
    Gritti F; Gilar M
    J Chromatogr A; 2019 Apr; 1591():110-119. PubMed ID: 30686649
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of the column hardware volume on resolution in very high pressure liquid chromatography non-invasive investigations.
    Gritti F; McDonald T; Gilar M
    J Chromatogr A; 2015 Nov; 1420():54-65. PubMed ID: 26472470
    [TBL] [Abstract][Full Text] [Related]  

  • 3. On the relationship between radial structure heterogeneities and efficiency of chromatographic columns.
    Gritti F
    J Chromatogr A; 2018 Jan; 1533():112-126. PubMed ID: 29254865
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterization of peak capacity of microbore liquid chromatography columns using gradient kinetic plots.
    Hetzel T; Blaesing C; Jaeger M; Teutenberg T; Schmidt TC
    J Chromatogr A; 2017 Feb; 1485():62-69. PubMed ID: 28093205
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Band broadening in fast gradient high-performance liquid chromatography: application to the second generation of 4.6 mm I.D. silica monolithic columns.
    Gritti F; Guiochon G
    J Chromatogr A; 2012 May; 1238():77-90. PubMed ID: 22503619
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intrinsic advantages of packed capillaries over narrow-bore columns in very high-pressure gradient liquid chromatography.
    Gritti F; McDonald T; Gilar M
    J Chromatogr A; 2016 Jun; 1451():107-119. PubMed ID: 27185055
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of parallel segmented flow chromatography on the height equivalent to a theoretical plate. I-performance of 4.6mm×30mm columns packed with 3.0μm Hypurity-C18 fully porous particles.
    Gritti F; Guiochon G
    J Chromatogr A; 2013 Jul; 1297():64-76. PubMed ID: 23706347
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A stochastic view on column efficiency.
    Gritti F
    J Chromatogr A; 2018 Mar; 1540():55-67. PubMed ID: 29448995
    [TBL] [Abstract][Full Text] [Related]  

  • 9. On the performance of conically shaped columns: Theory and practice.
    Gritti F; Belanger J; Izzo G; Leveille W
    J Chromatogr A; 2019 May; 1593():34-46. PubMed ID: 30704777
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multi-particle frits for packed capillary columns in electrochromatographic use.
    Sun J; Yang S; Cheng H; Wang Y; Liu J
    J Chromatogr A; 2019 Jun; 1595():221-229. PubMed ID: 30826077
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of nanoflow liquid chromatography using core-shell particles: A comparison study.
    Liu Y; Sun K; Shao C; Shi X; Zeng J; Guo R; Zhang B
    J Chromatogr A; 2021 Jul; 1648():462218. PubMed ID: 33992996
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Extraction of intrinsic column peak profiles of narrow-bore and microbore columns by peak deconvolution methods.
    Gritti F; Wahab F
    Anal Chim Acta; 2021 Oct; 1180():338851. PubMed ID: 34538318
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Theoretical and experimental impact of the bed aspect ratio on the axial dispersion coefficient of columns packed with 2.5 μm particles.
    Gritti F; Guiochon G
    J Chromatogr A; 2012 Nov; 1262():107-21. PubMed ID: 23010248
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Slow injector-to-column sample transport to maximize resolution in liquid chromatography: Theory versus practice.
    Gritti F; Tanaka N
    J Chromatogr A; 2019 Aug; 1600():219-237. PubMed ID: 31060782
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the gradient kinetic performance of silica monolithic capillary columns with columns packed with 3 μm porous and 2.7 μm fused-core silica particles.
    Vaast A; Broeckhoven K; Dolman S; Desmet G; Eeltink S
    J Chromatogr A; 2012 Mar; 1228():270-5. PubMed ID: 21855077
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fast gradient screening of pharmaceuticals with 5 cm long, narrow bore reversed-phase columns packed with sub-3 μm core-shell and sub-2 μm totally porous particles.
    Fekete S; Fekete J
    Talanta; 2011 Apr; 84(2):416-23. PubMed ID: 21376967
    [TBL] [Abstract][Full Text] [Related]  

  • 17. 1.1 μm superficially porous particles for liquid chromatography: part II: column packing and chromatographic performance.
    Blue LE; Jorgenson JW
    J Chromatogr A; 2015 Feb; 1380():71-80. PubMed ID: 25578043
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Visualization of sample introduction in liquid chromatography columns. The effect of the frit diameter.
    Broyles BS; Shalliker RA; Guiochon G
    J Chromatogr A; 1999 Sep; 855(2):367-82. PubMed ID: 10519081
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of parallel segmented flow chromatography on the height equivalent to a theoretical plate II - performances of 4.6mm×30mm columns packed with 2.6μm Accucore-C18 superficially porous particles.
    Gritti F; Guiochon G
    J Chromatogr A; 2013 Nov; 1314():44-53. PubMed ID: 24050598
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterization and kinetic performance of 2.1 × 100 mm production columns packed with new 1.6 μm superficially porous particles.
    Gritti F; Shiner S; Fairchild JN; Guiochon G
    J Sep Sci; 2014 Dec; 37(23):3418-25. PubMed ID: 25219365
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.