336 related articles for article (PubMed ID: 30695103)
1. Time stability of delta-radiomics features and the impact on patient analysis in longitudinal CT images.
Plautz TE; Zheng C; Noid G; Li XA
Med Phys; 2019 Apr; 46(4):1663-1676. PubMed ID: 30695103
[TBL] [Abstract][Full Text] [Related]
2. The impact of phantom design and material-dependence on repeatability and reproducibility of CT-based radiomics features.
Li Y; Reyhan M; Zhang Y; Wang X; Zhou J; Zhang Y; Yue NJ; Nie K
Med Phys; 2022 Mar; 49(3):1648-1659. PubMed ID: 35103332
[TBL] [Abstract][Full Text] [Related]
3. Intrinsic dependencies of CT radiomic features on voxel size and number of gray levels.
Shafiq-Ul-Hassan M; Zhang GG; Latifi K; Ullah G; Hunt DC; Balagurunathan Y; Abdalah MA; Schabath MB; Goldgof DG; Mackin D; Court LE; Gillies RJ; Moros EG
Med Phys; 2017 Mar; 44(3):1050-1062. PubMed ID: 28112418
[TBL] [Abstract][Full Text] [Related]
4. Technical Note: Proof of concept for radiomics-based quality assurance for computed tomography.
Branco LRF; Ger RB; Mackin DS; Zhou S; Court LE; Layman RR
J Appl Clin Med Phys; 2019 Nov; 20(11):199-205. PubMed ID: 31609076
[TBL] [Abstract][Full Text] [Related]
5. Longitudinal acquisition repeatability of MRI radiomics features: An ACR MRI phantom study on two MRI scanners using a 3D T1W TSE sequence.
Wong OL; Yuan J; Zhou Y; Yu SK; Cheung KY
Med Phys; 2021 Mar; 48(3):1239-1249. PubMed ID: 33370474
[TBL] [Abstract][Full Text] [Related]
6. Statistical Analysis on Impact of Image Preprocessing of CT Texture Patterns and Its CT Radiomic Feature Stability: A Phantom Study.
Palani D; Ganesh KM; Karunagaran L; Govindaraj K; Shanmugam S
Asian Pac J Cancer Prev; 2023 Jun; 24(6):2061-2072. PubMed ID: 37378937
[TBL] [Abstract][Full Text] [Related]
7. Reliability of CT-based texture features: Phantom study.
Varghese BA; Hwang D; Cen SY; Levy J; Liu D; Lau C; Rivas M; Desai B; Goodenough DJ; Duddalwar VA
J Appl Clin Med Phys; 2019 Aug; 20(8):155-163. PubMed ID: 31222919
[TBL] [Abstract][Full Text] [Related]
8. Variability in CT lung-nodule quantification: Effects of dose reduction and reconstruction methods on density and texture based features.
Lo P; Young S; Kim HJ; Brown MS; McNitt-Gray MF
Med Phys; 2016 Aug; 43(8):4854. PubMed ID: 27487903
[TBL] [Abstract][Full Text] [Related]
9. Evaluating the impact of extended field-of-view CT reconstructions on CT values and dosimetric accuracy for radiation therapy.
Cheung JP; Shugard E; Mistry N; Pouliot J; Chen J
Med Phys; 2019 Feb; 46(2):892-901. PubMed ID: 30457170
[TBL] [Abstract][Full Text] [Related]
10. Influence of gray level discretization on radiomic feature stability for different CT scanners, tube currents and slice thicknesses: a comprehensive phantom study.
Larue RTHM; van Timmeren JE; de Jong EEC; Feliciani G; Leijenaar RTH; Schreurs WMJ; Sosef MN; Raat FHPJ; van der Zande FHR; Das M; van Elmpt W; Lambin P
Acta Oncol; 2017 Nov; 56(11):1544-1553. PubMed ID: 28885084
[TBL] [Abstract][Full Text] [Related]
11. 3D-printed iodine-ink CT phantom for radiomics feature extraction - advantages and challenges.
Bach M; Aberle C; Depeursinge A; Jimenez-Del-Toro O; Schaer R; Flouris K; Konukoglu E; Müller H; Stieltjes B; Obmann MM
Med Phys; 2023 Sep; 50(9):5682-5697. PubMed ID: 36945890
[TBL] [Abstract][Full Text] [Related]
12. Comparison of low-contrast detectability between two CT reconstruction algorithms using voxel-based 3D printed textured phantoms.
Solomon J; Ba A; Bochud F; Samei E
Med Phys; 2016 Dec; 43(12):6497. PubMed ID: 27908164
[TBL] [Abstract][Full Text] [Related]
13. Assessment of treatment response during chemoradiation therapy for pancreatic cancer based on quantitative radiomic analysis of daily CTs: An exploratory study.
Chen X; Oshima K; Schott D; Wu H; Hall W; Song Y; Tao Y; Li D; Zheng C; Knechtges P; Erickson B; Li XA
PLoS One; 2017; 12(6):e0178961. PubMed ID: 28575105
[TBL] [Abstract][Full Text] [Related]
14. Measuring Computed Tomography Scanner Variability of Radiomics Features.
Mackin D; Fave X; Zhang L; Fried D; Yang J; Taylor B; Rodriguez-Rivera E; Dodge C; Jones AK; Court L
Invest Radiol; 2015 Nov; 50(11):757-65. PubMed ID: 26115366
[TBL] [Abstract][Full Text] [Related]
15. Analysing the possibility of utilizing CBCT radiomics as an independent modality: a phantom study.
Palani D; Shanmugam S; Govindaraj K
Asian Pac J Cancer Prev; 2021 May; 22(5):1383-1391. PubMed ID: 34048165
[TBL] [Abstract][Full Text] [Related]
16. Precision of quantitative computed tomography texture analysis using image filtering: A phantom study for scanner variability.
Yasaka K; Akai H; Mackin D; Court L; Moros E; Ohtomo K; Kiryu S
Medicine (Baltimore); 2017 May; 96(21):e6993. PubMed ID: 28538408
[TBL] [Abstract][Full Text] [Related]
17. 100 days with scans of the same Catphan phantom on the same CT scanner.
Husby E; Svendsen ED; Andersen HK; Martinsen ACT
J Appl Clin Med Phys; 2017 Nov; 18(6):224-231. PubMed ID: 28921910
[TBL] [Abstract][Full Text] [Related]
18. Identification of reproducible radiomic features from on-board volumetric images: A multi-institutional phantom study.
Adachi T; Nakamura M; Iramina H; Matsumoto K; Ishihara Y; Tachibana H; Kurokawa S; Cho S; Tanaka K; Fukumoto K; Nishiyama T; Kito S; Mizowaki T
Med Phys; 2023 Sep; 50(9):5585-5596. PubMed ID: 36932977
[TBL] [Abstract][Full Text] [Related]
19. Technical and clinical considerations of a physical liver phantom for CT radiomics analysis.
Varghese BA; Cen SY; Jensen K; Levy J; Andersen HK; Schulz A; Lei X; Duddalwar VA; Goodenough DJ
J Appl Clin Med Phys; 2024 Apr; 25(4):e14309. PubMed ID: 38386922
[TBL] [Abstract][Full Text] [Related]
20. Intra-scanner repeatability of quantitative imaging features in a 3D printed semi-anthropomorphic CT phantom.
Muenzfeld H; Nowak C; Riedlberger S; Hartenstein A; Hamm B; Jahnke P; Penzkofer T
Eur J Radiol; 2021 Aug; 141():109818. PubMed ID: 34157639
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]