These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 30698118)

  • 1. Analyzing Boron in 9-12% Chromium Steels Using Atom Probe Tomography.
    Fedorova I; Grumsen FB; Hald J; Andrén HO; Liu F
    Microsc Microanal; 2019 Apr; 25(2):462-469. PubMed ID: 30698118
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Atomic scale investigation of non-equilibrium segregation of boron in a quenched Mo-free martensitic steel.
    Li YJ; Ponge D; Choi P; Raabe D
    Ultramicroscopy; 2015 Dec; 159 Pt 2():240-7. PubMed ID: 25801276
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Atomic scale investigation on the distribution of boron in medium carbon steels by atom probe tomography and EELS.
    Bok Seol J; Ho Gu G; Suk Lim N; Das S; Gyung Park C
    Ultramicroscopy; 2010 Jun; 110(7):783-8. PubMed ID: 20356677
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Correlative Site-Specific Sample Preparation for Atom Probe Tomography on Complex Microstructures.
    Campo Schneider LP; Barrirero J; Pauly C; Guitar A; Mücklich F
    Microsc Microanal; 2021 Jun; ():1-10. PubMed ID: 34080531
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Grain boundary study of technically pure molybdenum by combining APT and TKD.
    Babinsky K; Knabl W; Lorich A; De Kloe R; Clemens H; Primig S
    Ultramicroscopy; 2015 Dec; 159 Pt 2():445-51. PubMed ID: 26025208
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Precipitate design for creep strengthening of 9% Cr tempered martensitic steel for ultra-supercritical power plants.
    Abe F
    Sci Technol Adv Mater; 2008 Jan; 9(1):013002. PubMed ID: 27877920
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel approach for site-specific atom probe specimen preparation by focused ion beam and transmission electron backscatter diffraction.
    Babinsky K; De Kloe R; Clemens H; Primig S
    Ultramicroscopy; 2014 Sep; 144():9-18. PubMed ID: 24815026
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Co-precipitated and collocated carbides and Cu-rich precipitates in a Fe-Cu steel characterized by atom-probe tomography.
    Kolli RP; Seidman DN
    Microsc Microanal; 2014 Dec; 20(6):1727-39. PubMed ID: 25254942
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Implementing Transmission Electron Backscatter Diffraction for Atom Probe Tomography.
    Rice KP; Chen Y; Prosa TJ; Larson DJ
    Microsc Microanal; 2016 Jun; 22(3):583-8. PubMed ID: 27329309
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Specimen preparation for correlating transmission electron microscopy and atom probe tomography of mesoscale features.
    Hartshorne MI; Isheim D; Seidman DN; Taheri ML
    Ultramicroscopy; 2014 Dec; 147():25-32. PubMed ID: 24976357
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Interface segregation behavior in thermal aged austenitic precipitation strengthened stainless steel.
    Li H; Song H; Liu W; Xia S; Zhou B; Su C; Ding W
    Ultramicroscopy; 2015 Dec; 159 Pt 2():255-64. PubMed ID: 26142697
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Al
    Chen Y; Rice KP; Prosa TJ; Reed RC; Marquis EA
    Microsc Microanal; 2022 May; ():1-10. PubMed ID: 35549785
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of detector dead-time on quantitative analyses involving boron and multi-hit detection events in atom probe tomography.
    Meisenkothen F; Steel EB; Prosa TJ; Henry KT; Prakash Kolli R
    Ultramicroscopy; 2015 Dec; 159 Pt 1():101-11. PubMed ID: 26342554
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of carbide precipitate morphology on fracture toughness in low-tempered steels containing Ni.
    Krawczyk J; Bała P; Pacyna J
    J Microsc; 2010 Mar; 237(3):411-5. PubMed ID: 20500408
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Interface Segregation and Nitrogen Measurement in Fe-Mn-N Steel by Atom Probe Tomography.
    Langelier B; Van Landeghem HP; Botton GA; Zurob HS
    Microsc Microanal; 2017 Apr; 23(2):385-395. PubMed ID: 28322178
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Novel Etching Technique for Delineation of Prior-Austenite Grain Boundaries in Low, Medium and High Carbon Steels.
    Thackray R; Palmiere EJ; Khalid O
    Materials (Basel); 2020 Jul; 13(15):. PubMed ID: 32722152
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improving Compositional Accuracy in APT Analysis of Carbides Using a Decreased Detection Efficiency.
    Thuvander M; Shinde D; Rehan A; Ejnermark S; Stiller K
    Microsc Microanal; 2019 Apr; 25(2):454-461. PubMed ID: 31018882
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reflections on the Analysis of Interfaces and Grain Boundaries by Atom Probe Tomography.
    Jenkins BM; Danoix F; Gouné M; Bagot PAJ; Peng Z; Moody MP; Gault B
    Microsc Microanal; 2020 Apr; 26(2):247-257. PubMed ID: 32186276
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Shaping the lens of the atom probe: fabrication of site specific, oriented specimens and application to grain boundary analysis.
    Felfer P; Ringer SP; Cairney JM
    Ultramicroscopy; 2011 May; 111(6):435-9. PubMed ID: 21247698
    [TBL] [Abstract][Full Text] [Related]  

  • 20. APT analysis of WC-Co based cemented carbides.
    Weidow J; Andrén HO
    Ultramicroscopy; 2011 May; 111(6):595-9. PubMed ID: 21664543
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.