These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

249 related articles for article (PubMed ID: 3069846)

  • 1. The use of dense alumina-alumina ceramic combination in total hip replacement.
    Boutin P; Christel P; Dorlot JM; Meunier A; de Roquancourt A; Blanquaert D; Herman S; Sedel L; Witvoet J
    J Biomed Mater Res; 1988 Dec; 22(12):1203-32. PubMed ID: 3069846
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Conus hip prosthesis.
    Wagner H; Wagner M
    Acta Chir Orthop Traumatol Cech; 2001; 68(4):213-21. PubMed ID: 11706545
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Alternative materials to improve total hip replacement tribology.
    Santavirta S; Böhler M; Harris WH; Konttinen YT; Lappalainen R; Muratoglu O; Rieker C; Salzer M
    Acta Orthop Scand; 2003 Aug; 74(4):380-8. PubMed ID: 14521286
    [TBL] [Abstract][Full Text] [Related]  

  • 4. All-ceramic fixed partial dentures. Studies on aluminum oxide- and zirconium dioxide-based ceramic systems.
    Vult von Steyern P
    Swed Dent J Suppl; 2005; (173):1-69. PubMed ID: 16001730
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Cementless acetabular fixation with solid alumina sockets. Apropos of 62 total hybrid prostheses with press-fit alumina sockets at 6-year mean follow-up].
    Hamadouche M; Nizard RS; Meunier A; Sedel L
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Sep; 86(5):474-81. PubMed ID: 10970971
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Wear properties of alumina/zirconia composite ceramics for joint prostheses measured with an end-face apparatus.
    Morita Y; Nakata K; Kim YH; Sekino T; Niihara K; Ikeuchi K
    Biomed Mater Eng; 2004; 14(3):263-70. PubMed ID: 15299238
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bone bonding behavior of bead-coated alumina ceramic under load-bearing conditions.
    Takagi H; Yamamuro T; Hyakuna K; Nakamura T; Kotoura Y; Oka M
    J Biomed Mater Res; 1989 Aug; 23(A2 Suppl):161-81. PubMed ID: 2674146
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ceramic materials as bearing surfaces for total hip arthroplasty.
    D'Antonio JA; Sutton K
    J Am Acad Orthop Surg; 2009 Feb; 17(2):63-8. PubMed ID: 19202119
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Poor outcome of 44 cemented total hip arthroplasties with alumina ceramic heads: clinical evaluation and retrieval analysis after 10-16 years.
    Hasegawa M; Ohashi T; Tani T
    Acta Orthop Scand; 2001 Oct; 72(5):449-56. PubMed ID: 11728070
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transfer of metallic debris after dislocation of ceramic femoral heads in hip prostheses.
    Müller FA; Hagymási M; Greil P; Zeiler G; Schuh A
    Arch Orthop Trauma Surg; 2006 Apr; 126(3):174-80. PubMed ID: 16482451
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The in vitro genotoxicity of orthopaedic ceramic (Al2O3) and metal (CoCr alloy) particles.
    Tsaousi A; Jones E; Case CP
    Mutat Res; 2010 Mar; 697(1-2):1-9. PubMed ID: 20139029
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Direct anchorage of Al2O3-ceramic hip components: three years of clinical experience and results of further animal studies.
    Heimke G; Griss P; Jentschura G; Werner E
    J Biomed Mater Res; 1979 Jan; 13(1):57-65. PubMed ID: 429385
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Role of ceramic implants. Design and clinical success with total hip prosthetic ceramic-to-ceramic bearings.
    Clarke IC
    Clin Orthop Relat Res; 1992 Sep; (282):19-30. PubMed ID: 1516312
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Strengthening of bone-implant interface by the use of granule coatings on alumina ceramics.
    Kakutani Y; Yamamuro T; Nakamura T; Kotoura Y
    J Biomed Mater Res; 1989 Jul; 23(7):781-808. PubMed ID: 2738088
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup.
    Popescu D; Gallart X; Garcia S; Bori G; Tomas X; Riba J
    Arch Orthop Trauma Surg; 2008 Aug; 128(8):783-5. PubMed ID: 18066561
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Osteolysis in third-generation alumina ceramic-on-ceramic hip bearings with severe impingement and titanium metallosis.
    Murali R; Bonar SF; Kirsh G; Walter WK; Walter WL
    J Arthroplasty; 2008 Dec; 23(8):1240.e13-9. PubMed ID: 18534463
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Zirconia as a sliding material: histologic, laboratory, and clinical data.
    Cales B
    Clin Orthop Relat Res; 2000 Oct; (379):94-112. PubMed ID: 11039797
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [10-year actuarial analysis of a cohort of 156 total hip prostheses of a cemented polished aluminum/polyethylene alloy].
    Le Mouel S; Allain J; Goutallier D
    Rev Chir Orthop Reparatrice Appar Mot; 1998 Jul; 84(4):338-45. PubMed ID: 9775034
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multilayered bead ceramic composite coating for hip prostheses: experimental studies and preliminary clinical results.
    Pizzoferrato A; Toni A; Sudanese A; Ciapetti G; Tinti A; Venturini A
    J Biomed Mater Res; 1988 Dec; 22(12):1181-202. PubMed ID: 3235458
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biocompatibility of surgical-grade dense polycrystalline alumina.
    Christel PS
    Clin Orthop Relat Res; 1992 Sep; (282):10-8. PubMed ID: 1516299
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.