BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 30699088)

  • 1. Effects of electrochemical processes application on the modification of mixed liquor characteristics of an electro-membrane bioreactor (e-MBR).
    Battistelli AA; da Costa RE; Dalri-Cecato L; Belli TJ; Lapolli FR
    Water Sci Technol; 2018 Dec; 78(11):2364-2373. PubMed ID: 30699088
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Application of a specific membrane fouling control enhancer in membrane bioreactor for real municipal wastewater treatment: Sludge characteristics and microbial community.
    Deng L; Guo W; Ngo HH; Wang XC; Hu Y; Chen R; Cheng D; Guo S; Cao Y
    Bioresour Technol; 2020 Sep; 312():123612. PubMed ID: 32526665
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Effect of aeration intensity on the filterability of mixed liquor in membrane bioreactor].
    Zhang HF; Sun BS; Zhao XH; Xu YH; Qi GS
    Huan Jing Ke Xue; 2008 Oct; 29(10):2777-82. PubMed ID: 19143370
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Application of electrochemical processes to membrane bioreactors for improving nutrient removal and fouling control.
    Borea L; Naddeo V; Belgiorno V
    Environ Sci Pollut Res Int; 2017 Jan; 24(1):321-333. PubMed ID: 27718113
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Self-generated electric field to suppress sludge production and fouling development in a membrane bioreactor for wastewater treatment.
    Yin X; Li J; Li X; Hua Z; Wang X; Ren Y
    Chemosphere; 2020 Dec; 261():128046. PubMed ID: 33113656
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Enhanced performance and hindered membrane fouling for the treatment of coal chemical industry wastewater using a novel membrane electro-bioreactor with intermittent direct current.
    Hou B; Kuang Y; Han H; Liu Y; Ren B; Deng R; Hursthouse AS
    Bioresour Technol; 2019 Jan; 271():332-339. PubMed ID: 30292132
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Application of powdered activated carbon (PAC) for membrane fouling control in a pilot-scale MBR system.
    Zouboulis AI; Gkotsis PK; Zamboulis DX; Mitrakas MG
    Water Sci Technol; 2017 May; 75(10):2350-2357. PubMed ID: 28541943
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrochemical membrane bioreactors: State-of-the-art and future prospects.
    Asif MB; Maqbool T; Zhang Z
    Sci Total Environ; 2020 Nov; 741():140233. PubMed ID: 32570070
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance of a laboratory-scale membrane bioreactor consisting mixed liquor with aquatic worms under toxic conditions.
    Navaratna D; Shu L; Jegatheesan V
    Bioresour Technol; 2014 Mar; 155():41-9. PubMed ID: 24413480
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of long-term ceramic membrane bioreactors without and with in-situ ozonation in wastewater treatment: Membrane fouling, effluent quality and microbial community.
    Tang S; Li J; Zhang Z; Ren B; Zhang X
    Sci Total Environ; 2019 Feb; 652():788-799. PubMed ID: 30380486
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Behaviour of biopolymeric substances in the activated sludge of an MBR system working with high hydraulic retention time.
    Marín E; Pérez JI; Gómez MA
    J Environ Sci Health A Tox Hazard Subst Environ Eng; 2017 Oct; 52(12):1184-1193. PubMed ID: 28910575
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fouling control in membrane bioreactors with sewage-sludge based adsorbents.
    Villamil JA; Monsalvo VM; Lopez J; Mohedano AF; Rodriguez JJ
    Water Res; 2016 Nov; 105():65-75. PubMed ID: 27596703
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Effect of sludge bulking on membrane fouling of MBR under low temperature].
    Ren NQ; Liu J; Wang XH
    Huan Jing Ke Xue; 2009 Jan; 30(1):155-9. PubMed ID: 19353874
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Effects of sludge retention time (SRT) on the characteristics of membrane bioreactor (MBR)].
    Zhang JL; Cao ZP; Zhang HW
    Huan Jing Ke Xue; 2008 Oct; 29(10):2788-93. PubMed ID: 19143372
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Nitrification performance in a membrane bioreactor treating industrial wastewater.
    Dvořák L; Svojitka J; Wanner J; Wintgens T
    Water Res; 2013 Sep; 47(13):4412-21. PubMed ID: 23764592
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Wastewater treatment and fouling control in an electro algae-activated sludge membrane bioreactor.
    Corpuz MVA; Borea L; Senatore V; Castrogiovanni F; Buonerba A; Oliva G; Ballesteros F; Zarra T; Belgiorno V; Choo KH; Hasan SW; Naddeo V
    Sci Total Environ; 2021 Sep; 786():147475. PubMed ID: 33971601
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of powdered activated carbon dosing on sludge characteristics and estrogen removal in membrane bioreactors.
    Yang W; Paetkau M; Cicek N
    Water Sci Technol; 2010; 61(9):2193-8. PubMed ID: 20418614
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Alleviation of membrane fouling in a submerged membrane bioreactor with electrochemical oxidation mediated by in-situ free chlorine generation.
    Chung CM; Tobino T; Cho K; Yamamoto K
    Water Res; 2016 Jun; 96():52-61. PubMed ID: 27019465
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The positive roles of influent species immigration in mitigating membrane fouling in membrane bioreactors treating municipal wastewater.
    Xu R; Zhang W; Fu Y; Fan F; Zhou Z; Chen J; Liu W; Meng F
    Water Res; 2023 May; 235():119907. PubMed ID: 37001232
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of solid retention time and exposure mode to electric current on Remazol Brilliant Violet removal in an electro-membrane bioreactor.
    Belli TJ; Bassin JP; de Sousa Vidal CM; Hassemer MEN; Rodrigues C; Lapolli FR
    Environ Sci Pollut Res Int; 2023 Apr; 30(20):58412-58427. PubMed ID: 36991202
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.