These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 30703036)

  • 1. A 400 GΩ Input-Impedance Active Electrode for Non-Contact Capacitively Coupled ECG Acquisition With Large Linear-Input-Range and High CM-Interference-Tolerance.
    Chen M; Chun HS; Castro ID; Torfs T; Lin Q; van Hoof C; Wang G; Lian Y; van Helleputte N
    IEEE Trans Biomed Circuits Syst; 2019 Apr; 13(2):376-386. PubMed ID: 30703036
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Micropower Motion Artifact Estimator for Input Dynamic Range Reduction in Wearable ECG Acquisition Systems.
    Pholpoke B; Songthawornpong T; Wattanapanitch W
    IEEE Trans Biomed Circuits Syst; 2019 Oct; 13(5):1021-1035. PubMed ID: 31478870
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determining the input impedance of ECG amplifiers using accurate electrode modelling.
    Maji S; Burke MJ
    Biomed Phys Eng Express; 2020 Jan; 6(1):015030. PubMed ID: 33438618
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A 160 μW 8-Channel Active Electrode System for EEG Monitoring.
    Jiawei Xu ; Yazicioglu RF; Grundlehner B; Harpe P; Makinwa KA; Van Hoof C
    IEEE Trans Biomed Circuits Syst; 2011 Dec; 5(6):555-67. PubMed ID: 23852553
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Non-contact electrocardiogram measuring method based on capacitance coupling electrodes with ultra-high input impedance.
    Li J; Wang Y; Li C; Xu Z; Zhao Z; Raza SA; Wang Y
    Rev Sci Instrum; 2022 Mar; 93(3):034101. PubMed ID: 35365001
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Novel Stable Capacitive Electrocardiogram Measurement System.
    Chen CC; Lin SY; Chang WY
    Sensors (Basel); 2021 May; 21(11):. PubMed ID: 34070412
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A micropower dry-electrode ECG preamplifier.
    Burke MJ; Gleeson DT
    IEEE Trans Biomed Eng; 2000 Feb; 47(2):155-62. PubMed ID: 10721622
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Two-Wired Ultra-High Input Impedance Active Electrode.
    Guerrero FN; Spinelli EM
    IEEE Trans Biomed Circuits Syst; 2018 Apr; 12(2):437-445. PubMed ID: 29570069
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A Closed-Loop Neuromodulation Chipset With 2-Level Classification Achieving 1.5-Vpp CM Interference Tolerance, 35-dB Stimulation Artifact Rejection in 0.5ms and 97.8%-Sensitivity Seizure Detection.
    Wang Y; Luo H; Chen Y; Jiao Z; Sun Q; Dong L; Chen X; Wang X; Zhang H
    IEEE Trans Biomed Circuits Syst; 2021 Aug; 15(4):802-819. PubMed ID: 34388094
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A 160 μA biopotential acquisition IC with fully integrated IA and motion artifact suppression.
    Van Helleputte N; Kim S; Kim H; Kim JP; Van Hoof C; Yazicioglu RF
    IEEE Trans Biomed Circuits Syst; 2012 Dec; 6(6):552-61. PubMed ID: 23853256
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An 18.6-μW/Ch TDM-Based 8-Channel Noncontact ECG Recording IC with Common-Mode Interference Suppression.
    Choi KJ; Sim JY
    IEEE Trans Biomed Circuits Syst; 2022 Dec; PP():. PubMed ID: 37015407
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A 0.67 μV-IIRN super-T Ω-Z
    Dabbaghian A; El-Hajj Y; Ghalamboran M; Grau G; Kassiri H
    IEEE Trans Biomed Circuits Syst; 2024 Feb; 18(1):3-15. PubMed ID: 37535484
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Amplifier input impedance in dry electrode ECG recording.
    Assambo C; Burke MJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():1774-7. PubMed ID: 19964015
    [TBL] [Abstract][Full Text] [Related]  

  • 14. ECG simulator with configurable skin-electrode impedance and artifacts emulation.
    Almeida D; Costa J; Lourenço A
    Biomed Phys Eng Express; 2021 Oct; 7(6):. PubMed ID: 34587605
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultra-wearable capacitive coupled and common electrode-free ECG monitoring system.
    Komensky T; Jurcisin M; Ruman K; Kovac O; Laqua D; Husar P
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():1594-7. PubMed ID: 23366210
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A 108 dB DR Δ∑-∑M Front-End With 720 mV
    Yang X; Xu J; Ballini M; Chun H; Zhao M; Wu X; Van Hoof C; Mora Lopez C; Van Helleputte N
    IEEE Trans Biomed Circuits Syst; 2021 Apr; 15(2):199-209. PubMed ID: 33646955
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An impedance matching algorithm for common-mode interference removal in vagus nerve recordings.
    Levy TJ; Ahmed U; Tsaava T; Chang YC; Lorraine PJ; Tomaio JN; Cracchiolo M; Lopez M; Rieth L; Tracey KJ; Zanos S; Zanos TP
    J Neurosci Methods; 2020 Jan; 330():108467. PubMed ID: 31654663
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electrode Humidification Design for Artifact Reduction in Capacitive ECG Measurements.
    Tang Y; Chang R; Zhang L; Yan F; Ma H; Bu X
    Sensors (Basel); 2020 Jun; 20(12):. PubMed ID: 32570924
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Capacitive driven-right-leg grounding in Indirect-contact ECG measurement.
    Lim YG; Chung GS; Park KS
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():1250-3. PubMed ID: 21095911
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A 2.55 NEF 76 dB CMRR DC-Coupled Fully Differential Difference Amplifier Based Analog Front End for Wearable Biomedical Sensors.
    Zhao Y; Shang Z; Lian Y
    IEEE Trans Biomed Circuits Syst; 2019 Oct; 13(5):918-926. PubMed ID: 31247560
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.