578 related articles for article (PubMed ID: 30703125)
1. Determinants of corrosion resistance of Ti-6Al-4V alloy dental implants in an In Vitro model of peri-implant inflammation.
Berbel LO; Banczek EDP; Karoussis IK; Kotsakis GA; Costa I
PLoS One; 2019; 14(1):e0210530. PubMed ID: 30703125
[TBL] [Abstract][Full Text] [Related]
2. Electrochemical studies of the corrosion behaviour of titanium and the Ti-6Al-4V alloy using electrochemical impedance spectroscopy.
Grosgogeat B; Boinet M; Dalard F; Lissac M
Biomed Mater Eng; 2004; 14(3):323-31. PubMed ID: 15299244
[TBL] [Abstract][Full Text] [Related]
3. Comparative corrosion study of Ti-Ta alloys for dental applications.
Mareci D; Chelariu R; Gordin DM; Ungureanu G; Gloriant T
Acta Biomater; 2009 Nov; 5(9):3625-39. PubMed ID: 19508903
[TBL] [Abstract][Full Text] [Related]
4. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study.
Barão VA; Mathew MT; Assunção WG; Yuan JC; Wimmer MA; Sukotjo C
Clin Oral Implants Res; 2012 Sep; 23(9):1055-62. PubMed ID: 22092540
[TBL] [Abstract][Full Text] [Related]
5. Increasing temperature accelerates Ti-6Al-4V oxide degradation and selective dissolution: An Arrhenius-based analysis.
Kurtz MA; Alaniz K; Taylor LM; Moreno-Reyes A; Gilbert JL
Acta Biomater; 2024 Apr; 178():352-365. PubMed ID: 38417644
[TBL] [Abstract][Full Text] [Related]
6. Comparative analysis of corrosion resistance between beta titanium and Ti-6Al-4V alloys: A systematic review.
Dias Corpa Tardelli J; Bolfarini C; Cândido Dos Reis A
J Trace Elem Med Biol; 2020 Dec; 62():126618. PubMed ID: 32663743
[TBL] [Abstract][Full Text] [Related]
7. Attachment of Porphyromonas gingivalis to corroded commercially pure titanium and titanium-aluminum-vanadium alloy.
Barão VA; Yoon CJ; Mathew MT; Yuan JC; Wu CD; Sukotjo C
J Periodontol; 2014 Sep; 85(9):1275-82. PubMed ID: 24444400
[TBL] [Abstract][Full Text] [Related]
8. The development of Ti alloys for dental implant with high corrosion resistance and mechanical strength.
Yamazoe J; Nakagawa M; Matono Y; Takeuchi A; Ishikawa K
Dent Mater J; 2007 Mar; 26(2):260-7. PubMed ID: 17621943
[TBL] [Abstract][Full Text] [Related]
9. Corrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions.
Nakagawa M; Matsuya S; Udoh K
Dent Mater J; 2001 Dec; 20(4):305-14. PubMed ID: 11915624
[TBL] [Abstract][Full Text] [Related]
10. Electrochemical impedance spectroscopy study of Ti-6Al-4V alloy in artificial saliva with fluoride and/or bovine albumin.
Huang HH; Lee TH
Dent Mater; 2005 Aug; 21(8):749-55. PubMed ID: 15878783
[TBL] [Abstract][Full Text] [Related]
11. Adsorption of Candida albicans on Ti-6Al-4V surface and its corrosion effects in artificial saliva.
Zeng F; Li Y; Chen K; Li G; Liu C; Wang L; Li L; Qu Q
Bioelectrochemistry; 2022 Dec; 148():108248. PubMed ID: 35988504
[TBL] [Abstract][Full Text] [Related]
12. In-situ monitoring of the electrochemical behavior of cellular structured biomedical Ti-6Al-4V alloy fabricated by electron beam melting in simulated physiological fluid.
Gai X; Bai Y; Li S; Hou W; Hao Y; Zhang X; Yang R; Misra RDK
Acta Biomater; 2020 Apr; 106():387-395. PubMed ID: 32058079
[TBL] [Abstract][Full Text] [Related]
13. Elucidating the corrosion-related degradation mechanisms of a Ti-6Al-4V dental implant.
Chen X; Shah K; Dong S; Peterson L; Callagon La Plante E; Sant G
Dent Mater; 2020 Mar; 36(3):431-441. PubMed ID: 31992484
[TBL] [Abstract][Full Text] [Related]
14. Effects of dextrose and lipopolysaccharide on the corrosion behavior of a Ti-6Al-4V alloy with a smooth surface or treated with double-acid-etching.
Faverani LP; Assunção WG; de Carvalho PS; Yuan JC; Sukotjo C; Mathew MT; Barao VA
PLoS One; 2014; 9(3):e93377. PubMed ID: 24671257
[TBL] [Abstract][Full Text] [Related]
15. Additively manufactured Ti-29Nb-21Zr shows improved oxide polarization resistance versus Ti-6Al-4V in inflammatory simulating solution.
Kurtz MA; Wessinger AC; Mace A; Moreno-Reyes A; Gilbert JL
J Biomed Mater Res A; 2023 Oct; 111(10):1538-1553. PubMed ID: 37129046
[TBL] [Abstract][Full Text] [Related]
16. The Role of Nicotine in the Corrosive Behavior of a Ti-6Al-4V Dental Implant.
Royhman D; Dominguez-Benetton X; Yuan JC; Shokuhfar T; Takoudis C; Mathew MT; Sukotjo C
Clin Implant Dent Relat Res; 2015 Oct; 17 Suppl 2():e352-63. PubMed ID: 25066431
[TBL] [Abstract][Full Text] [Related]
17. Fretting corrosion behaviour of Ti-6Al-4V reinforced with zirconia in foetal bovine serum.
Semetse L; Obadele BA; Raganya L; Geringer J; Olubambi PA
J Mech Behav Biomed Mater; 2019 Dec; 100():103392. PubMed ID: 31430704
[TBL] [Abstract][Full Text] [Related]
18. The role of titanium implant surface modification with hydroxyapatite nanoparticles in progressive early bone-implant fixation in vivo.
Lin A; Wang CJ; Kelly J; Gubbi P; Nishimura I
Int J Oral Maxillofac Implants; 2009; 24(5):808-16. PubMed ID: 19865620
[TBL] [Abstract][Full Text] [Related]
19. [Effect of fluoride ion on corrosion of two dental titanium alloys].
Cao BW; Chen L
Hua Xi Kou Qiang Yi Xue Za Zhi; 2010 Jun; 28(3):261-4. PubMed ID: 20635653
[TBL] [Abstract][Full Text] [Related]
20. An electrochemical impedance investigation of the behaviour of anodically oxidised titanium in human plasma and cognate fluids, relevant to dental applications.
Bozzini B; Carlino P; D'Urzo L; Pepe V; Mele C; Venturo F
J Mater Sci Mater Med; 2008 Nov; 19(11):3443-53. PubMed ID: 18584125
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]