These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
184 related articles for article (PubMed ID: 30704930)
21. Guidelines for the choice of circumferential wrought wire and cast clasp arms for removable partial dentures. Owen CP; Naidoo N Int Dent J; 2022 Feb; 72(1):58-66. PubMed ID: 33622544 [TBL] [Abstract][Full Text] [Related]
22. Fitness and retentive force of cobalt-chromium alloy clasps fabricated with repeated laser sintering and milling. Torii M; Nakata T; Takahashi K; Kawamura N; Shimpo H; Ohkubo C J Prosthodont Res; 2018 Jul; 62(3):342-346. PubMed ID: 29428170 [TBL] [Abstract][Full Text] [Related]
23. Effect of acetyl resin retentive arms on the retentive force of circumferential clasps: an in vitro study. de Torres ÉM; de Siqueira Damasceno II; do Amaral BA; Rodrigues RC; Carreiro Ada F; Ribeiro RF J Prosthodont Res; 2012 Jul; 56(3):216-21. PubMed ID: 22104622 [TBL] [Abstract][Full Text] [Related]
24. New Clasp Assembly for Distal Extension Removable Partial Dentures: The Reverse RPA Clasp. Hakkoum MA J Prosthodont; 2016 Jul; 25(5):411-3. PubMed ID: 26102601 [TBL] [Abstract][Full Text] [Related]
25. Effect of buccal part designs of polyamide resin partial removable dental prosthesis on retentive force. Taguchi Y; Shimamura I; Sakurai K J Prosthodont Res; 2011 Jan; 55(1):44-7. PubMed ID: 20971693 [TBL] [Abstract][Full Text] [Related]
26. Comparative analysis of the retention force and deformation of PEEK and PEKK removable partial denture clasps with different thicknesses and undercut depths. Lee WF; Chen MS; Peng TY; Huang PC; Nikawa H; Peng PW J Prosthet Dent; 2024 Feb; 131(2):291.e1-291.e9. PubMed ID: 38057199 [TBL] [Abstract][Full Text] [Related]
27. Deformation and retentive force following in vitro cyclic fatigue of cobalt-chrome and aryl ketone polymer (AKP) clasps. Marie A; Keeling A; Hyde TP; Nattress BR; Pavitt S; Murphy RJ; Shary TJ; Dillon S; Osnes C; Wood DJ Dent Mater; 2019 Jun; 35(6):e113-e121. PubMed ID: 30948229 [TBL] [Abstract][Full Text] [Related]
28. [Experimental study on the retentive force of cobalt-chromium alloy, pure titanium and vitallium cast clasps in the simulated 3-year clinical use]. Yan HX; Zhao YB; Qin LM; Zhu HT; Wu L Shanghai Kou Qiang Yi Xue; 2015 Dec; 24(6):696-701. PubMed ID: 27063121 [TBL] [Abstract][Full Text] [Related]
29. Fitness accuracy and retentive forces of additive manufactured titanium clasp. Takahashi K; Torii M; Nakata T; Kawamura N; Shimpo H; Ohkubo C J Prosthodont Res; 2020 Oct; 64(4):468-477. PubMed ID: 32063534 [TBL] [Abstract][Full Text] [Related]
30. Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture. Sćepanović M; Tihacek-Sojić L; Tasić M; Mitrović R; Todorović A; Trifković B Vojnosanit Pregl; 2013 Nov; 70(11):999-1005. PubMed ID: 24397193 [TBL] [Abstract][Full Text] [Related]
32. A new design for partial denture circumferential clasp arms. Brockhurst PJ Aust Dent J; 1996 Oct; 41(5):317-23. PubMed ID: 8961605 [TBL] [Abstract][Full Text] [Related]
33. Effects of long-term simulated RPD clasp attachment/detachment on retention loss and wear for two clasp types and three abutment material surfaces. Helal MA; Baraka OA; Sanad ME; Ludwig K; Kern M J Prosthodont; 2012 Jul; 21(5):370-7. PubMed ID: 22443158 [TBL] [Abstract][Full Text] [Related]
34. Analytical model of I-bar clasps for removable partial dentures. Richert R; Alsheghri AA; Alageel O; Caron E; Song J; Ducret M; Tamimi F Dent Mater; 2021 Jun; 37(6):1066-1072. PubMed ID: 33867171 [TBL] [Abstract][Full Text] [Related]
35. Evaluation of the retentive force of a b-type Ti-6Mo-4Sn alloy wire clasp. Yoda N; Yokoyama M; Adachi G; Takahashi M; Sasaki K Int J Prosthodont; 2010; 23(1):38-41. PubMed ID: 20234890 [TBL] [Abstract][Full Text] [Related]
36. An Evaluation of Retentive Ability and Deformation of Acetal Resin and Cobalt-Chromium Clasps. Meenakshi A; Gupta R; Bharti V; Sriramaprabu G; Prabhakar R J Clin Diagn Res; 2016 Jan; 10(1):ZC37-41. PubMed ID: 26894173 [TBL] [Abstract][Full Text] [Related]
37. Fabrication of crown restoration retrofitting to existing clasps using CAD/CAM: fitness accuracy and retentive force. Ozawa D; Suzuki Y; Kawamura N; Ohkubo C J Prosthodont Res; 2015 Apr; 59(2):136-43. PubMed ID: 25662150 [TBL] [Abstract][Full Text] [Related]
38. Dimensional measurement and finite element analysis of I-bar clasps in clinical use. Sato Y; Tsuga K; Abe Y; Asahara S; Akagawa Y J Oral Rehabil; 2000 Nov; 27(11):935-9. PubMed ID: 11106984 [TBL] [Abstract][Full Text] [Related]
39. Feasibility study and material selection for powder-bed fusion process in printing of denture clasps. Ma K; Chen H; Shen Y; Guo Y; Li W; Wang Y; Zhang Y; Sun Y Comput Biol Med; 2023 May; 157():106772. PubMed ID: 36963354 [TBL] [Abstract][Full Text] [Related]
40. Retentive Forces and Deformation of Fitting Surface in RPD Clasp Made of Polyether-Ether-Ketone (PEEK). Vaddamanu SK; Alhamoudi FH; Chaturvedi S; Alqahtani NM; Addas MK; Alfarsi MA; Vyas R; Kanji MA; Zarbah MA; Alqahtani WMS; Alqahtani SM; Abdelmonem AM; Elmahdi AE Polymers (Basel); 2023 Feb; 15(4):. PubMed ID: 36850239 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]