These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 30709229)

  • 1. Image-plate sensitivity to x rays at 2 to 60 keV.
    Rosenberg MJ; Thorn DB; Izumi N; Williams D; Rowland M; Torres G; Haugh M; Hillyard P; Adelman N; Schuler T; Barrios MA; Holder JP; Schneider MB; Fournier KB; Bradley DK; Regan SP
    Rev Sci Instrum; 2019 Jan; 90(1):013506. PubMed ID: 30709229
    [TBL] [Abstract][Full Text] [Related]  

  • 2. On the system stability and calibration of the image plate/scanner system for plasma diagnosis at the National Ignition Facility.
    Holder JP; Izumi N; Beach M; Ayers MJ; Bell P; Schneider M; Bradley DK; Kohut T; Ehrlich R; Cohen M; Ramirez R; Thorn D
    Rev Sci Instrum; 2018 Oct; 89(10):10F123. PubMed ID: 30399981
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of the sensitivity and fading characteristics of an image plate system for x-ray diagnostics.
    Meadowcroft AL; Bentley CD; Stott EN
    Rev Sci Instrum; 2008 Nov; 79(11):113102. PubMed ID: 19045884
    [TBL] [Abstract][Full Text] [Related]  

  • 4. X-ray modulation transfer functions of photostimulable phosphor image plates and scanners.
    Seely JF; Holland GE; Hudson LT; Henins A
    Appl Opt; 2008 Nov; 47(31):5753-61. PubMed ID: 19122716
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Absolute calibration of imaging plate detectors for electron kinetic energies between 150 keV and 1.75 MeV.
    Singh S; Slavicek T; Hodak R; Versaci R; Pridal P; Kumar D
    Rev Sci Instrum; 2017 Jul; 88(7):075105. PubMed ID: 28764518
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validation of modelled imaging plates sensitivity to 1-100 keV x-rays and spatial resolution characterisation for diagnostics for the "PETawatt Aquitaine Laser".
    Boutoux G; Batani D; Burgy F; Ducret JE; Forestier-Colleoni P; Hulin S; Rabhi N; Duval A; Lecherbourg L; Reverdin C; Jakubowska K; Szabo CI; Bastiani-Ceccotti S; Consoli F; Curcio A; De Angelis R; Ingenito F; Baggio J; Raffestin D
    Rev Sci Instrum; 2016 Apr; 87(4):043108. PubMed ID: 27131655
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cross-calibration of Fuji TR image plate and RAR 2492 x-ray film to determine the response of a DITABIS Super Micron image plate scanner.
    Dunham G; Harding EC; Loisel GP; Lake PW; Nielsen-Weber LB
    Rev Sci Instrum; 2016 Nov; 87(11):11E301. PubMed ID: 27910495
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterization of Agfa Structurix series D4 and D3sc x-ray films in the 0.7-4.6 keV energy range.
    Dutra EC; Cowan J; Cunningham T; Durand AM; Emig J; Heeter RF; Knauer J; Knight RA; Lara R; Perry TS; Rodriguez Z; Torres G; Wallace MS
    Rev Sci Instrum; 2021 Jul; 92(7):075103. PubMed ID: 34340426
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Image plate characterization and absolute calibration to low kilo-electron-volt electrons.
    Busold S; Philipp K; Otten A; Roth M
    Rev Sci Instrum; 2014 Nov; 85(11):113306. PubMed ID: 25430109
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Absolute response of Fuji imaging plate detectors to picosecond-electron bunches.
    Zeil K; Kraft SD; Jochmann A; Kroll F; Jahr W; Schramm U; Karsch L; Pawelke J; Hidding B; Pretzler G
    Rev Sci Instrum; 2010 Jan; 81(1):013307. PubMed ID: 20113093
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Absolute calibration of image plates for electrons at energy between 100 keV and 4 MeV.
    Chen H; Back NL; Bartal T; Beg FN; Eder DC; Link AJ; MacPhee AG; Ping Y; Song PM; Throop A; Van Woerkom L
    Rev Sci Instrum; 2008 Mar; 79(3):033301. PubMed ID: 18377001
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Energy dependent calibration of XR-QA2 radiochromic film with monochromatic and polychromatic x-ray beams.
    Di Lillo F; Mettivier G; Sarno A; Tromba G; Tomic N; Devic S; Russo P
    Med Phys; 2016 Jan; 43(1):583. PubMed ID: 26745950
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Response functions of Fuji imaging plates to monoenergetic protons in the energy range 0.6-3.2 MeV.
    Bonnet T; Comet M; Denis-Petit D; Gobet F; Hannachi F; Tarisien M; Versteegen M; Aleonard MM
    Rev Sci Instrum; 2013 Jan; 84(1):013508. PubMed ID: 23387651
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Imaging plates for use with synchrotron radiation.
    Amemiya Y
    J Synchrotron Radiat; 1995 Jan; 2(Pt 1):13-21. PubMed ID: 16714781
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Study of imaging plate detector sensitivity to 5-18 MeV electrons.
    Boutoux G; Rabhi N; Batani D; Binet A; Ducret JE; Jakubowska K; Nègre JP; Reverdin C; Thfoin I
    Rev Sci Instrum; 2015 Nov; 86(11):113304. PubMed ID: 26628126
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High-energy x-ray backlighter spectrum measurements using calibrated image plates.
    Maddox BR; Park HS; Remington BA; Izumi N; Chen S; Chen C; Kimminau G; Ali Z; Haugh MJ; Ma Q
    Rev Sci Instrum; 2011 Feb; 82(2):023111. PubMed ID: 21361577
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Flat field anomalies in an x-ray charge coupled device camera measured using a Manson x-ray source.
    Haugh MJ; Schneider MB
    Rev Sci Instrum; 2008 Oct; 79(10):10E925. PubMed ID: 19044580
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fresnel zone plate development for x-ray radiography of hydrodynamic instabilities at the National Ignition Facility.
    Do A; Pickworth LA; Kozioziemski BJ; Angulo AM; Hall GN; Nagel SR; Bradley DK; Mccarville T; Ayers JM
    Appl Opt; 2020 Dec; 59(34):10777-10785. PubMed ID: 33361898
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Calibration and equivalency analysis of image plate scanners.
    Williams GJ; Maddox BR; Chen H; Kojima S; Millecchia M
    Rev Sci Instrum; 2014 Nov; 85(11):11E604. PubMed ID: 25430350
    [TBL] [Abstract][Full Text] [Related]  

  • 20. New knowledge about the bremsstrahlung image of strontium-89 with the scintillation camera.
    Narita H; Hirase K; Uchiyama M; Fukushi M
    Ann Nucl Med; 2012 Aug; 26(7):603-7. PubMed ID: 22767009
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.