161 related articles for article (PubMed ID: 30709606)
1. The Impact of Head of Bed Elevation on Optic Nerve Sheath Diameter in Cervical Collar Applied Healthy Volunteers.
Sanri E; Karacabey S
J Emerg Med; 2019 Apr; 56(4):371-377. PubMed ID: 30709606
[TBL] [Abstract][Full Text] [Related]
2. Placement of a cervical collar increases the optic nerve sheath diameter in healthy adults.
Woster CM; Zwank MD; Pasquarella JR; Wewerka SS; Anderson JP; Greupner JT; Motalib S
Am J Emerg Med; 2018 Mar; 36(3):430-434. PubMed ID: 28865838
[TBL] [Abstract][Full Text] [Related]
3. The Influence of Cervical Collar Immobilization on Optic Nerve Sheath Diameter.
Yard J; Richman PB; Leeson B; Leeson K; Youngblood G; Guardiola J; Miller M
J Emerg Trauma Shock; 2019; 12(2):141-144. PubMed ID: 31198282
[TBL] [Abstract][Full Text] [Related]
4. The effects of spinal immobilization at 20° on intracranial pressure.
Özdoğan S; Gökçek Ö; Katırcı Y; Çorbacıoğlu ŞK; Emektar E; Çevik Y
Am J Emerg Med; 2019 Jul; 37(7):1327-1330. PubMed ID: 30327158
[TBL] [Abstract][Full Text] [Related]
5. The Measurement of Elderly Volunteers' Optic Nerve Sheath Diameters by Ocular Ultrasonography.
Avci M; Kozaci N; Komut E; Komut S; Caliskan G; Tulubas G
Medicina (Kaunas); 2019 Jul; 55(8):. PubMed ID: 31357667
[TBL] [Abstract][Full Text] [Related]
6. Increase in intracranial pressure by application of a rigid cervical collar: a pilot study in healthy volunteers.
Maissan IM; Ketelaars R; Vlottes B; Hoeks SE; den Hartog D; Stolker RJ
Eur J Emerg Med; 2018 Dec; 25(6):e24-e28. PubMed ID: 28727580
[TBL] [Abstract][Full Text] [Related]
7. The Effect of Different Posture on Normal Saline Injection in Optic Nerve Sheath Diameter in Thoracic Epidural Anesthesia.
Park J; Hong J; Kim J; Yi S
Pain Physician; 2020 Nov; 23(6):573-579. PubMed ID: 33185374
[TBL] [Abstract][Full Text] [Related]
8. Effect of 5 different cervical collars on optic nerve sheath diameter: A randomized crossover trial.
Ladny M; Smereka J; Ahuja S; Szarpak L; Ruetzler K; Ladny JR
Medicine (Baltimore); 2020 Apr; 99(16):e19740. PubMed ID: 32311968
[TBL] [Abstract][Full Text] [Related]
9. Cervical Interlaminar Epidural Injections at High Doses Do Not Increase Optic Nerve Sheath Diameter on a Long-Term Basis.
Kim H; O JH; Hong SJ; Shin KM; Park J; Kang SS
Pain Physician; 2016; 19(8):E1173-E1179. PubMed ID: 27906948
[TBL] [Abstract][Full Text] [Related]
10. Role of serial ultrasonic optic nerve sheath diameter monitoring in head injury.
Thotakura AK; Marabathina NR; Danaboyina AR; Mareddy RR
Neurochirurgie; 2017 Dec; 63(6):444-448. PubMed ID: 29122307
[TBL] [Abstract][Full Text] [Related]
11. Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma.
Strumwasser A; Kwan RO; Yeung L; Miraflor E; Ereso A; Castro-Moure F; Patel A; Sadjadi J; Victorino GP
J Surg Res; 2011 Oct; 170(2):265-71. PubMed ID: 21550065
[TBL] [Abstract][Full Text] [Related]
12. Can optic nerve sheath diameter assessment be used as a non-invasive tool to dynamically monitor intracranial pressure?
Wu GB; Tian J; Liu XB; Wang ZY; Guo JY
J Integr Neurosci; 2022 Mar; 21(2):54. PubMed ID: 35364642
[TBL] [Abstract][Full Text] [Related]
13. Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure.
Maissan IM; Dirven PJ; Haitsma IK; Hoeks SE; Gommers D; Stolker RJ
J Neurosurg; 2015 Sep; 123(3):743-7. PubMed ID: 25955869
[TBL] [Abstract][Full Text] [Related]
14. Changes in intraocular pressure and optic nerve sheath diameter in patients undergoing robotic-assisted laparoscopic prostatectomy in steep 45° Trendelenburg position.
Blecha S; Harth M; Schlachetzki F; Zeman F; Blecha C; Flora P; Burger M; Denzinger S; Graf BM; Helbig H; Pawlik MT
BMC Anesthesiol; 2017 Mar; 17(1):40. PubMed ID: 28284189
[TBL] [Abstract][Full Text] [Related]
15. Optic nerve sheath diameter measurement: a means of detecting raised ICP in adult traumatic and non-traumatic neurosurgical patients.
Raffiz M; Abdullah JM
Am J Emerg Med; 2017 Jan; 35(1):150-153. PubMed ID: 27852525
[TBL] [Abstract][Full Text] [Related]
16. Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure during laparoscopic surgery: a systematic review and meta-analysis.
Kim EJ; Koo BN; Choi SH; Park K; Kim MS
Surg Endosc; 2018 Jan; 32(1):175-182. PubMed ID: 28639043
[TBL] [Abstract][Full Text] [Related]
17. Optic nerve sheath diameter asymmetry in healthy subjects and patients with intracranial hypertension.
Naldi A; Provero P; Vercelli A; Bergui M; Mazzeo AT; Cantello R; Tondo G; Lochner P
Neurol Sci; 2020 Feb; 41(2):329-333. PubMed ID: 31586289
[TBL] [Abstract][Full Text] [Related]
18. The Effect of Speed of Normal Saline Injection on Optic Nerve Sheath Diameter in Thoracic Epidural Anesthesia.
Hong JH; Jung SW; Park JH
Pain Physician; 2019 Jul; 22(4):E325-E332. PubMed ID: 31337174
[TBL] [Abstract][Full Text] [Related]
19. Assessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement.
Liu D; Li Z; Zhang X; Zhao L; Jia J; Sun F; Wang Y; Ma D; Wei W
BMC Neurol; 2017 Sep; 17(1):188. PubMed ID: 28962603
[TBL] [Abstract][Full Text] [Related]
20. Helicopter Transportation Increases Intracranial Pressure: a Proof-of-Principle Study.
Maissan IM; Verbaan LA; van den Berg M; Houmes RJ; Stolker RJ; den Hartog D
Air Med J; 2018; 37(4):249-252. PubMed ID: 29935704
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]